Sri Ganesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sri Ganesh has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Sheetal Brar
Department of Phaco and Refractive Services, Nethradhama Super Speciality Eye Hospital, Bangalore, Karnataka, India
8 shared publications Nikhil Rp
2 shared publicationsArindam Dey
Alcon Laboratories (India) Private Ltd, Bengaluru, India
1 shared publicationChandra Kumar H.
Nethradhama Superspeciality Eye Hospital, Bangalore, India
1 shared publicationDandapani Ramamurthy
Department of Cornea, Cataract and Refractive Services, The Eye Foundation, Coimbatore, India
1 shared publicationDhwni Shahanand
1 shared publication
Latest Publications
- Open Access
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2685-2695
Comparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems
Purpose: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Study Design: Prospective, interventional, 3-arm, randomized comparison study. Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed. Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable. Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems. Ctri Registration Number: CTRI/2022/01/039296.
- 1 September 2024
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 18, 2685-2695
Open AccessComparative Clinical Study of Surgical Performance of Quatera 700 versus Centurion and Signature Pro Phacoemulsification Systems
Purpose: To compare the intra-operative surgical performance of Quatera 700 with Centurion and Signature Pro phacoemulsification systems. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Study Design: Prospective, interventional, 3-arm, randomized comparison study. Methods: A total of 180 non-consecutive eyes satisfying the eligibility criteria were recruited. N = 60 eyes were operated using each of the above systems, of which n = 30 eyes had LOCS III grade 1– 2, and n = 30 eyes had grade 3– 4 nuclear density. Phacoemulsification with foldable IOL implantation was performed by a single experienced surgeon. Chamber stability scores (1– 4, 4 being the worst), fluid turnover per case, surge incidence and intra-operative complications were assessed. Results: Intra-operatively, the mean chamber stability score was significantly better for the Quatera 700 in both the soft and dense cataract groups compared to the other two machines (p < 0.001). Total Phaco Time (TPT) with Quatera 700 was significantly lower compared to Signature Pro, while it was comparable with Centurion for both the soft and dense cataract groups. The mean fluid turnover was significantly lower for the Quatera 700 in the dense cataract group (p = 0.04) and so was the combined phaco and I/A time (p = 0.01) when compared with Signature Pro. One eye operated with Signature Pro and 2 eyes operated with Centurion had PCR due to surge. The mean corneal clarity scores on POD-1 and specular counts at 2 weeks and 6 months were comparable. Conclusion: The new Quatera 700 system resulted in lesser TPT, fluid turnover and phaco + I/A time than Signature Pro, while its performance was comparable to Centurion for these parameters. Moreover, the surgeon graded intra-operative chamber stability scoring was highest, when compared to the other two systems. Ctri Registration Number: CTRI/2022/01/039296.
- Open Access
- 23 August 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (9) , 1236-1243
Laser refractive correction of presbyopia
Presbyopia is an inevitable and progressive loss of the eye’s ability to focus on nearby objects due to aging, which affects everyone regardless of their refractive error. Uncorrected presbyopia is a significant burden worldwide and affects the quality of life. Conservative options include spectacle correction, contact lenses, and pharmacologic agents. Spectacles are commonly used to correct vision, but have certain drawbacks such as peripheral blur and impaired depth perception. These limitations have been associated with an increased risk of accidental falls. Several surgical options are available to address these issues, including cornea-based, lens-based, or scleral procedures. These procedures involve modifying the cornea’s optics, replacing the crystalline lens, or attempting to restore accommodation. Each of the options has its benefits and limitations. One of the most common surgical methods of presbyopic correction that has recently become popular is presbyopic Laser assisted In situ keratomileusis (LASIK) due to its improved safety and efficacy. This article is a review of all the currently available data and studies regarding the various methods of correction of presbyopia, with an emphasis on the principles and outcomes of the corneal laser refractive procedures for presbyopia correction, such as PresbyLASIK, Supracor, PRESBYOND laser blended vision, and Custom Q.
- 23 August 2024
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 72 (9) , 1236-1243
Open AccessLaser refractive correction of presbyopia
Presbyopia is an inevitable and progressive loss of the eye’s ability to focus on nearby objects due to aging, which affects everyone regardless of their refractive error. Uncorrected presbyopia is a significant burden worldwide and affects the quality of life. Conservative options include spectacle correction, contact lenses, and pharmacologic agents. Spectacles are commonly used to correct vision, but have certain drawbacks such as peripheral blur and impaired depth perception. These limitations have been associated with an increased risk of accidental falls. Several surgical options are available to address these issues, including cornea-based, lens-based, or scleral procedures. These procedures involve modifying the cornea’s optics, replacing the crystalline lens, or attempting to restore accommodation. Each of the options has its benefits and limitations. One of the most common surgical methods of presbyopic correction that has recently become popular is presbyopic Laser assisted In situ keratomileusis (LASIK) due to its improved safety and efficacy. This article is a review of all the currently available data and studies regarding the various methods of correction of presbyopia, with an emphasis on the principles and outcomes of the corneal laser refractive procedures for presbyopia correction, such as PresbyLASIK, Supracor, PRESBYOND laser blended vision, and Custom Q.
- 1 July 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (7) , 718-723
Clinical outcomes and rotational stability after implantation of a monofocal toric intraocular lens with textured haptics in normal vs high axial lengths
Purpose: To compare the clinical outcomes and rotational stability after implantation of a toric intraocular lens (IOL) with textured haptics in eyes with normal vs high axial lengths (ALs). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: 2-arm, retrospective comparative study. Methods: This retrospective study included 114 eyes of 114 patients who underwent femtolaser cataract surgery followed by implantation of the HOYA Vivinex Toric monofocal IOL (Model XY1A-SP), of which 62 and 52 eyes belonged to normal (≤23.9 mm) and high (≥24 mm) AL groups, respectively. 1 week and 3 months postoperatively, clinical outcomes and rotational stability of the toric IOL was evaluated. Results: 3 months postoperatively, % eyes achieving refractive astigmatism accuracy within ≤0.50 diopter, was 100% (n = 62) in the normal vs 94% (n = 49) in the high AL group. All eyes that is, 100% (n = 62) in the normal and 96.15% (n = 50) eyes in the high myopia group were P = .80). No significant correlation was observed between AL and white-to-white diameter with 1-week postoperative rotation values. No eye required repositioning of toric IOL for significant misalignment. Conclusions: No significant differences were observed for clinical outcomes and postoperative rotational stability between eyes with normal and high ALs, suggesting excellent rotational stability of the Vivinex Toric IOL with textured haptics in all eyes, irrespective of the preoperative AL measurements.
- 1 July 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (7) , 718-723
Clinical outcomes and rotational stability after implantation of a monofocal toric intraocular lens with textured haptics in normal vs high axial lengths
Purpose: To compare the clinical outcomes and rotational stability after implantation of a toric intraocular lens (IOL) with textured haptics in eyes with normal vs high axial lengths (ALs). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: 2-arm, retrospective comparative study. Methods: This retrospective study included 114 eyes of 114 patients who underwent femtolaser cataract surgery followed by implantation of the HOYA Vivinex Toric monofocal IOL (Model XY1A-SP), of which 62 and 52 eyes belonged to normal (≤23.9 mm) and high (≥24 mm) AL groups, respectively. 1 week and 3 months postoperatively, clinical outcomes and rotational stability of the toric IOL was evaluated. Results: 3 months postoperatively, % eyes achieving refractive astigmatism accuracy within ≤0.50 diopter, was 100% (n = 62) in the normal vs 94% (n = 49) in the high AL group. All eyes that is, 100% (n = 62) in the normal and 96.15% (n = 50) eyes in the high myopia group were P = .80). No significant correlation was observed between AL and white-to-white diameter with 1-week postoperative rotation values. No eye required repositioning of toric IOL for significant misalignment. Conclusions: No significant differences were observed for clinical outcomes and postoperative rotational stability between eyes with normal and high ALs, suggesting excellent rotational stability of the Vivinex Toric IOL with textured haptics in all eyes, irrespective of the preoperative AL measurements.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 572-577
Changes in endothelial cell density after conventional phacoemulsification and FLACS in eyes with dense cataracts
Purpose: To compare the safety, effectiveness, and changes in endothelial cell density (ECD) after standard phacoemulsification and femtosecond laser-assisted cataract surgery (FLACS) in dense cataracts (Lens Opacities Classification System III grade 3.0 NO and above). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Prospective, randomized, comparative study. Method: 100 eyes of 100 patients were randomly assigned to either conventional phacoemulsification surgery (CPS) or FLACS (LENSAR Laser System) using predefined patterns of nuclear fragmentations. Measured outcomes included intraoperative phacoemulsification time, irrigation fluid volume, surgical time, and complication rates. ECD was evaluated at baseline, 2 weeks, and 6 months postoperatively. Results: The CPS group had significantly higher mean total phacoemulsification time (11.17 ± 6.5 seconds vs 8.03 ± 3.77 seconds), effective phacoemulsification time (6.14 ± 3.62 seconds vs 4.42 ± 2.07 seconds), and total surgical time (8.18 ± 2.36 minutes vs 7.11 ± 1.55 minutes) than the FLACS group (P < .001). Volume of irrigation fluid was comparable between the 2 groups (CPS, 36.7 ± 12.18 mL; FLACS, 38.64 ± 13.73 mL (P = .45). Mean corneal edema score and central corneal thickness values on postoperative day 1 were significantly higher for the CPS group. At 6 months, % ECD loss was significantly higher in the CPS group (16.08%) vs the FLACS group (12.8%) (P < .001). 3 eyes in the CPS group had wound burns of varying severity. Conclusions: FLACS with customized nuclear fragmentation patterns resulted in significantly less intraoperative phacoemulsification time, surgical time, and endothelial cell loss compared with conventional phacoemulsification when treating dense cataracts. Trial Registration Number: CTRI/2021/12/038887.
- 1 June 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (6) , 572-577
Changes in endothelial cell density after conventional phacoemulsification and FLACS in eyes with dense cataracts
Purpose: To compare the safety, effectiveness, and changes in endothelial cell density (ECD) after standard phacoemulsification and femtosecond laser-assisted cataract surgery (FLACS) in dense cataracts (Lens Opacities Classification System III grade 3.0 NO and above). Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Design: Prospective, randomized, comparative study. Method: 100 eyes of 100 patients were randomly assigned to either conventional phacoemulsification surgery (CPS) or FLACS (LENSAR Laser System) using predefined patterns of nuclear fragmentations. Measured outcomes included intraoperative phacoemulsification time, irrigation fluid volume, surgical time, and complication rates. ECD was evaluated at baseline, 2 weeks, and 6 months postoperatively. Results: The CPS group had significantly higher mean total phacoemulsification time (11.17 ± 6.5 seconds vs 8.03 ± 3.77 seconds), effective phacoemulsification time (6.14 ± 3.62 seconds vs 4.42 ± 2.07 seconds), and total surgical time (8.18 ± 2.36 minutes vs 7.11 ± 1.55 minutes) than the FLACS group (P < .001). Volume of irrigation fluid was comparable between the 2 groups (CPS, 36.7 ± 12.18 mL; FLACS, 38.64 ± 13.73 mL (P = .45). Mean corneal edema score and central corneal thickness values on postoperative day 1 were significantly higher for the CPS group. At 6 months, % ECD loss was significantly higher in the CPS group (16.08%) vs the FLACS group (12.8%) (P < .001). 3 eyes in the CPS group had wound burns of varying severity. Conclusions: FLACS with customized nuclear fragmentation patterns resulted in significantly less intraoperative phacoemulsification time, surgical time, and endothelial cell loss compared with conventional phacoemulsification when treating dense cataracts. Trial Registration Number: CTRI/2021/12/038887.
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 790-794
Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
Purpose: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Method: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. Results: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). Conclusions: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. Trial Registration Number: CTRI/2021/11/038053.
- 1 August 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (8) , 790-794
Interobserver agreement between central topography and Scheimpflug tomography for premium intraocular lens selection
Purpose: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. Setting: Nethradhama Superspeciality Eye Hospital, Bangalore, India. Method: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. Results: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). Conclusions: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. Trial Registration Number: CTRI/2021/11/038053.
- Open Access
- 16 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 4215-4225
Twelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in an Indian Population
Purpose: To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods: This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥ 20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons’ satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results: A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53± 0.44 logMAR preoperatively to 0.00± 0.08 logMAR at week 1 and − 0.03± 0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78± 0.40 logMAR preoperatively, 0.11± 0.15 logMAR at week 1, and 0.08± 0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion: The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.
- 16 December 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 4215-4225
Open AccessTwelve-Months Follow-Up Postmarket Study of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in an Indian Population
Purpose: To assess real-world clinical outcomes and safety of the Clareon® intraocular lens (IOL) and AutonoMe® automated preloaded delivery system in an Indian population. Patients and methods: This was a prospective, single-arm, multicenter, 12-month clinical study in patients aged ≥ 20 years with unilateral or bilateral cataracts. Surgery was performed by phacoemulsification followed by implantation of the Clareon monofocal IOL (CNA0T0). Monocular best-corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were assessed at 1 week and 1, 6, and 12 months after implantation. Posterior capsular opacification (PCO), surface haze, and glistenings were evaluated at all visits. Surgeons’ satisfaction with automated injector system was also evaluated using a questionnaire. Safety was assessed by monitoring adverse events (AEs). Results: A total of 151 eyes received the CNA0T0 IOL. Mean ± SD monocular BCDVA improved from 0.53± 0.44 logMAR preoperatively to 0.00± 0.08 logMAR at week 1 and − 0.03± 0.08 logMAR at 12 months after implantation. At 12 months, 137/137 (100%) of eyes achieved BCDVA of 0.3 logMAR or better. Mean ± SD monocular UCDVA was 0.78± 0.40 logMAR preoperatively, 0.11± 0.15 logMAR at week 1, and 0.08± 0.13 logMAR at 12 months after implantation. At 12 months, 132/137 (96%) eyes achieved UCDVA of 0.3 logMAR or better. Serious intraoperative AEs were posterior capsule rupture (n=1) and ciliary zonular dehiscence (n=1). Surgeons reported that the automated preloaded device was more intuitive compared with other push- or screw-style preloaded injector systems. None of the eyes in this study presented surface haze; all were graded as 0 glistenings at all visits. No clinically significant PCO or neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomies were reported. Conclusion: The hydrophobic IOL preloaded in an automated injector system provided good visual and refractive outcomes, as well as no surface haze and grade 0 glistenings. None of the patients required Nd:YAG capsulotomy.
- Open Access
- 1 October 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 4247-4257
Clinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
Purpose: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs). Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated. Results: A total of 60 eyes from 30 patients with a mean age of 65.40± 7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ± 0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤ 0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16± 0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01± 0.09 and 0.03± 0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up. Conclusion: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction. Trial Registry: CTRI/2020/08/027105 (www.ctri.nic.in).
- 1 October 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 4247-4257
Open AccessClinical Outcomes, Contrast Sensitivity, Reading Performance and Patient Satisfaction Following Bilateral Implantation of AT LARA 829MP EDoF IOLs
Purpose: To evaluate the visual outcomes, contrast sensitivity, reading performance and patient satisfaction after bilateral implantation of AT LARA extended depth of focus (EDoF) intraocular lenses (IOLs). Methods: Patients undergoing phacoemulsification for age-related cataract and satisfying the eligibility criteria underwent bilateral implantation with AT LARA EDoF IOLs (Carl Zeiss Meditec, Jena, Germany). At follow-up visits of 1, 3, 6 and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, defocus curve, contrast sensitivity and patient satisfaction for dysphotopsia and spectacle independence were evaluated. Results: A total of 60 eyes from 30 patients with a mean age of 65.40± 7.71 years were included in the study. At 12 months, 83% of patients (n=25) had binocular cumulative uncorrected distance visual acuity (UDVA) of 20/20 or better. Postoperative spherical equivalent refraction accuracy was within ± 0.50 D for 95% of eyes (n=57) and refractive cylinder accuracy was within ≤ 0.50 D in 95% of eyes (n=57). The mean binocular uncorrected near visual acuity (UNVA) was 0.16± 0.09 logMAR, and the mean uncorrected intermediate visual acuity (UIVA) at 60 and 80 cm was 0.01± 0.09 and 0.03± 0.08 logMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement over time. No patient had complaints of severe dysphotopsia and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant posterior capsule opacification at the end of mean follow-up. Conclusion: In our limited experience of 30 patients at 12 months, AT LARA EDoF IOLs resulted in excellent visual outcomes for uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia and spectacle dependence was low, resulting in good patient satisfaction. Trial Registry: CTRI/2020/08/027105 (www.ctri.nic.in).
- Open Access
- 1 August 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 3247-3257
Clinical Outcomes and Patient Satisfaction with a New Diffractive-Refractive Trifocal Intraocular Lens – A 12 Month Prospective Study
Purpose: To evaluate the clinical outcomes and patient satisfaction after implantation of Optiflex Trio, a new trifocal intraocular lens (IOL) following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataracts and who satisfy the eligibility criteria underwent bilateral implantation with Optiflex Trio trifocal IOL. At follow -up visits of 1, 3, 6, and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, contrast sensitivity (CS) and patient satisfaction for dysphotopsia and spectacle independence were evaluated using questionnaires. Results: A total of 54 eyes from 27 patients with mean age of 66.30± 7.48 years were included in the study. At 12 months, 78% (n = 21) patients had binocular cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 93% (n = 50) eyes, and refractive cylinder accuracy was within ≤ 0.50 D in 94% (n = 51) eyes. The mean binocular UNVA was 0.01± 0.05 LogMAR, and the mean UIVA at 60 and 80 cm was 0.07± 0.06 and 0.03± 0.05 LogMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement overtime. No patient had complained of severe dysphotopsia, and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant PCO at the end of mean follow-up. Conclusion: After 12 months, Optiflex Trio trifocal IOL provided a complete visual restoration with good visual quality outcomes in terms of uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia was low, and spectacle independence was high, resulting in good patient satisfaction. Trial Registry: CTRI/2019/10/021647 (www.ctri.nic.in).
- 1 August 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 3247-3257
Open AccessClinical Outcomes and Patient Satisfaction with a New Diffractive-Refractive Trifocal Intraocular Lens – A 12 Month Prospective Study
Purpose: To evaluate the clinical outcomes and patient satisfaction after implantation of Optiflex Trio, a new trifocal intraocular lens (IOL) following cataract surgery. Methods: Patients undergoing phacoemulsification for age-related cataracts and who satisfy the eligibility criteria underwent bilateral implantation with Optiflex Trio trifocal IOL. At follow -up visits of 1, 3, 6, and 12 months, binocular uncorrected and corrected distance, intermediate and near visual acuity, reading performance, contrast sensitivity (CS) and patient satisfaction for dysphotopsia and spectacle independence were evaluated using questionnaires. Results: A total of 54 eyes from 27 patients with mean age of 66.30± 7.48 years were included in the study. At 12 months, 78% (n = 21) patients had binocular cumulative UDVA of 20/20 or better. Post-op SE refraction accuracy was within ± 0.50 D for 93% (n = 50) eyes, and refractive cylinder accuracy was within ≤ 0.50 D in 94% (n = 51) eyes. The mean binocular UNVA was 0.01± 0.05 LogMAR, and the mean UIVA at 60 and 80 cm was 0.07± 0.06 and 0.03± 0.05 LogMAR, respectively, at 12 months. Reading speeds at 40, 60 and 80 cm showed improvement overtime. No patient had complained of severe dysphotopsia, and none of the patients required glasses for any activity. No eye underwent YAG-laser capsulotomy for significant PCO at the end of mean follow-up. Conclusion: After 12 months, Optiflex Trio trifocal IOL provided a complete visual restoration with good visual quality outcomes in terms of uncorrected distance, intermediate and near visual acuity. The incidence of dysphotopsia was low, and spectacle independence was high, resulting in good patient satisfaction. Trial Registry: CTRI/2019/10/021647 (www.ctri.nic.in).
- Open Access
- 1 June 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2607-2617
A Prospective, Comparative, Clinical Study to Evaluate the Safety and Efficacy of Two Different 0.1% Riboflavin Solutions Used in Collagen Crosslinking Treatment for Patients with Keratoconus
Purpose: To compare the safety and efficacy of 0.1% riboflavin in two different solutions which is used in corneal collagen crosslinking (CXL) for the treatment of keratoconus. Methods: This was a prospective, randomized, comparison study which included 100 eyes of 61 patients with progressive keratoconus who underwent CXL with riboflavin 0.1% solution as a photosensitizer, using the standard Dresden protocol of using 3mW/cm2 UV-A irradiation for 30 minutes which corresponds to a total energy of 5.4 J/cm2. The recruited patients were divided into 2 groups ie, Flavin Group and Peschke-D group by computer generated randomization. Postoperative examinations were conducted on 1 day, 1 month, 3 months, 6 months and 12 months after the crosslinking. Results: For both groups, the mean manifest spherical equivalent (SE), astigmatism, best corrected distance visual acuity, keratometry values, thinnest pachymetry values, demarcation line depth and endothelial cell density preoperatively and at postoperative 12 months were comparable with no statistically significant differences. At 12 months postoperatively, 62% of eyes in the Flavin group, and 68% of eyes in the Peschke-D group had postoperative manifest SE of within ± 1.00 D. During UV-A exposure, the cornea in the Flavin group showed intraoperative thinning of 112 microns (27%) as compared with a thinning of 108.12 microns (26.5%) observed in the Peschke group (p=1.67) from the initial pachymetry readings. No eye in either group had any immediate or long-term postop vision threatening complications such as infectious keratitis, corneal melt, non-resolving corneal oedema or endothelial decompensation. Conclusion: Both riboflavin solutions were equally safe and effective in the management of progressive keratoconus, and resulted in similar changes in terms of mean manifest spherical equivalent (SE), astigmatism, best corrected distance visual acuity, keratometry values, thinnest pachymetry values, demarcation line depth and endothelial cell density at the end of 12 months postoperatively. Trial Registration Number: Ctri/2019/11/021841 (Www.ctri.nic.in).
- 1 June 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2607-2617
Open AccessA Prospective, Comparative, Clinical Study to Evaluate the Safety and Efficacy of Two Different 0.1% Riboflavin Solutions Used in Collagen Crosslinking Treatment for Patients with Keratoconus
Purpose: To compare the safety and efficacy of 0.1% riboflavin in two different solutions which is used in corneal collagen crosslinking (CXL) for the treatment of keratoconus. Methods: This was a prospective, randomized, comparison study which included 100 eyes of 61 patients with progressive keratoconus who underwent CXL with riboflavin 0.1% solution as a photosensitizer, using the standard Dresden protocol of using 3mW/cm2 UV-A irradiation for 30 minutes which corresponds to a total energy of 5.4 J/cm2. The recruited patients were divided into 2 groups ie, Flavin Group and Peschke-D group by computer generated randomization. Postoperative examinations were conducted on 1 day, 1 month, 3 months, 6 months and 12 months after the crosslinking. Results: For both groups, the mean manifest spherical equivalent (SE), astigmatism, best corrected distance visual acuity, keratometry values, thinnest pachymetry values, demarcation line depth and endothelial cell density preoperatively and at postoperative 12 months were comparable with no statistically significant differences. At 12 months postoperatively, 62% of eyes in the Flavin group, and 68% of eyes in the Peschke-D group had postoperative manifest SE of within ± 1.00 D. During UV-A exposure, the cornea in the Flavin group showed intraoperative thinning of 112 microns (27%) as compared with a thinning of 108.12 microns (26.5%) observed in the Peschke group (p=1.67) from the initial pachymetry readings. No eye in either group had any immediate or long-term postop vision threatening complications such as infectious keratitis, corneal melt, non-resolving corneal oedema or endothelial decompensation. Conclusion: Both riboflavin solutions were equally safe and effective in the management of progressive keratoconus, and resulted in similar changes in terms of mean manifest spherical equivalent (SE), astigmatism, best corrected distance visual acuity, keratometry values, thinnest pachymetry values, demarcation line depth and endothelial cell density at the end of 12 months postoperatively. Trial Registration Number: Ctri/2019/11/021841 (Www.ctri.nic.in).
- Open Access
- 1 May 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1839-1849
Visual and Refractive Outcomes and Patient Satisfaction Following Implantation of Monofocal IOL in One Eye and ERV IOL in the Contralateral Eye with Mini-Monovision
Title: Visual and refractive outcomes and patient satisfaction following implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral eye with mini-monovision. Purpose: To evaluate the outcomes following implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral eye with mini-monovision. Methods: Twenty-five subjects underwent bilateral cataract surgery, wherein the dominant eye received monofocal Tecnis-1 IOL, while in the contralateral eye received the Tecnis Symphony ERV IOL. The dominant eye was targeted for emmetropia and the non-dominant eye for myopia of − 0.50 to − 0.75D. Binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near (UNVA, DCNVA) visual acuity; reading speeds, defocus curve and contrast sensitivity were studied at 6 months post-operatively. Results: At 6 months post-operatively the mean binocular UDVA, CDVA, UNVA and DCNVA were 0.007± 0.07, − 0.13± 0.06, 0.26± 0.09 and 0.44± 0.10 LogMAR, respectively. Binocular UIVA and DCIVA at 60 cm were 0.22± 0.10 and 0.18± 0.08 LogMAR and at 80 cm was 0.16± 0.11 and 0.15± 0.10 LogMAR, respectively. Mean uncorrected reading speeds evaluated with SRD at 40, 60 and 80 cm were 114.4± 6.9, 126.4± 7.9 and 123.16± 5.8 words per minute. Contrast sensitivity values did not show significant difference for any spatial frequency tested. At 6 months, only 12% (3 patients) reported mild halos. Spectacle independence satisfaction scores were 96%, 100% and 88% for distance, intermediate and near. Conclusion: Implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral with mini-monovision resulted in good outcomes for far and intermediate, and satisfactory outcomes for near vision, with good tolerance to mini-monovision at the end of 6 months.
- 1 May 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1839-1849
Open AccessVisual and Refractive Outcomes and Patient Satisfaction Following Implantation of Monofocal IOL in One Eye and ERV IOL in the Contralateral Eye with Mini-Monovision
Title: Visual and refractive outcomes and patient satisfaction following implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral eye with mini-monovision. Purpose: To evaluate the outcomes following implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral eye with mini-monovision. Methods: Twenty-five subjects underwent bilateral cataract surgery, wherein the dominant eye received monofocal Tecnis-1 IOL, while in the contralateral eye received the Tecnis Symphony ERV IOL. The dominant eye was targeted for emmetropia and the non-dominant eye for myopia of − 0.50 to − 0.75D. Binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near (UNVA, DCNVA) visual acuity; reading speeds, defocus curve and contrast sensitivity were studied at 6 months post-operatively. Results: At 6 months post-operatively the mean binocular UDVA, CDVA, UNVA and DCNVA were 0.007± 0.07, − 0.13± 0.06, 0.26± 0.09 and 0.44± 0.10 LogMAR, respectively. Binocular UIVA and DCIVA at 60 cm were 0.22± 0.10 and 0.18± 0.08 LogMAR and at 80 cm was 0.16± 0.11 and 0.15± 0.10 LogMAR, respectively. Mean uncorrected reading speeds evaluated with SRD at 40, 60 and 80 cm were 114.4± 6.9, 126.4± 7.9 and 123.16± 5.8 words per minute. Contrast sensitivity values did not show significant difference for any spatial frequency tested. At 6 months, only 12% (3 patients) reported mild halos. Spectacle independence satisfaction scores were 96%, 100% and 88% for distance, intermediate and near. Conclusion: Implantation of monofocal intraocular lens in one eye and ERV intraocular lens in the contralateral with mini-monovision resulted in good outcomes for far and intermediate, and satisfactory outcomes for near vision, with good tolerance to mini-monovision at the end of 6 months.