Intra-urban spatial variability of surface ozone in Riverside, CA: viability and validation of low-cost sensors
Open Access
- 28 March 2018
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (3) , 1777-1792
Abstract
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere like ozone (O3). This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 in a 200 km2 area of Riverside County near Los Angeles, California. This tool contains low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 measurements to minute-resolution reference observations resulted in R2 and root mean squared errors (RMSEs) of 0.95–0.97 and 4.4–5.9 ppbv, respectively. Using the deployment data, ozone concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R2 values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppbv for the ozone deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values, we can conclude that there is spatial variability in this criteria pollutant across the study area. This is important because it means that citizens may be exposed to more, or less, ozone than they would assume based on current regulatory monitoring.Keywords
All Related Versions
Funding Information
- Division of Computing and Communication Foundations (1442971)
This publication has 19 references indexed in Scilit:
- Low-Cost Air Quality Monitoring Tools: From Research to Practice (A Workshop Summary)Sensors, 2017
- Community Air Sensor Network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United StatesAtmospheric Measurement Techniques, 2016
- The rise of low-cost sensing for managing air pollution in citiesEnvironment International, 2015
- Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxideAtmospheric Environment, 2015
- Spatial and temporal variability of air pollution in Birmingham, AlabamaAtmospheric Environment, 2014
- High Density Ozone Monitoring Using Gas Sensitive Semi-Conductor Sensors in the Lower Fraser Valley, British ColumbiaEnvironmental Science & Technology, 2014
- Day of week effects on diurnal ozone/NOx cycles and transportation emissions in Southern CaliforniaTransportation Research Part D: Transport and Environment, 2007
- Metal oxides for solid-state gas sensors: What determines our choice?Materials Science and Engineering: B, 2007
- Heterogeneous chemistry and tropospheric ozoneAtmospheric Environment, 2000
- Some Unique Aspects of Air Pollution in Los AngelesAir Repair, 1953