Kira Sadighi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kira Sadighi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Andrea Polidori
South Coast Air Quality Management District, Air Quality Sensor Performance Evaluation Center, 21865 Copley Drive, Diamond Bar, CA 91765-4178, USA
2 shared publicationsBrandon Feenstra
South Coast Air Quality Management District, Air Quality Sensor Performance Evaluation Center, 21865 Copley Drive, Diamond Bar, CA 91765-4178, USA
2 shared publicationsDaven K. Henze
Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, 1111 Engineering Drive, Boulder, CO 80309, USA
2 shared publicationsEvan Coffey
Department of Mechanical Engineering, University of Colorado Boulder, 427 UCB, 1111 Engineering Drive, Boulder, CO 80309, USA
2 shared publications- Michael Patrick Hannigan
University of Colorado Boulder
2 shared publications Qin Lv
Department of Computer Science, University of Colorado Boulder, 430 UCB, 1111 Engineering Drive, Boulder, CO 80309, USA
2 shared publications
Latest Publications
- Open Access
- 28 March 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (3) , 1777-1792
Intra-urban spatial variability of surface ozone in Riverside, CA: viability and validation of low-cost sensors
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere like ozone (O3). This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 in a 200 km2 area of Riverside County near Los Angeles, California. This tool contains low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 measurements to minute-resolution reference observations resulted in R2 and root mean squared errors (RMSEs) of 0.95–0.97 and 4.4–5.9 ppbv, respectively. Using the deployment data, ozone concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R2 values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppbv for the ozone deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values, we can conclude that there is spatial variability in this criteria pollutant across the study area. This is important because it means that citizens may be exposed to more, or less, ozone than they would assume based on current regulatory monitoring.
- 28 March 2018
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 11 (3) , 1777-1792
Open AccessIntra-urban spatial variability of surface ozone in Riverside, CA: viability and validation of low-cost sensors
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere like ozone (O3). This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 in a 200 km2 area of Riverside County near Los Angeles, California. This tool contains low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 measurements to minute-resolution reference observations resulted in R2 and root mean squared errors (RMSEs) of 0.95–0.97 and 4.4–5.9 ppbv, respectively. Using the deployment data, ozone concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R2 values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppbv for the ozone deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values, we can conclude that there is spatial variability in this criteria pollutant across the study area. This is important because it means that citizens may be exposed to more, or less, ozone than they would assume based on current regulatory monitoring.
- Open Access
Quantifying Neighborhood-Scale Spatial Variations of Ozone at Open Space and Urban Sites in Boulder, Colorado Using Low-Cost Sensor Technology
Recent advances in air pollution sensors have led to a new wave of low-cost measurement systems that can be deployed in dense networks to capture small-scale spatio-temporal variations in ozone, a pollutant known to cause negative human health impacts. This study deployed a network of seven low-cost ozone metal oxide sensor systems (UPods) in both an open space and an urban location in Boulder, Colorado during June and July of 2015, to quantify ozone variations on spatial scales ranging from 12 m between UPods to 6.7 km between open space and urban measurement sites with a measurement uncertainty of ~5 ppb. The results showed spatial variability of ozone at both deployment sites, with the largest differences between UPod measurements occurring during the afternoons. The peak median hourly difference between UPods was 6 ppb at 1:00 p.m. at the open space site, and 11 ppb at 4:00 p.m. at the urban site. Overall, the urban ozone measurements were higher than in the open space measurements. This study evaluates the effectiveness of using low-cost sensors to capture microscale spatial and temporal variation of ozone; additionally, it highlights the importance of field calibrations and measurement uncertainty quantification when deploying low-cost sensors.
Open AccessQuantifying Neighborhood-Scale Spatial Variations of Ozone at Open Space and Urban Sites in Boulder, Colorado Using Low-Cost Sensor Technology
Recent advances in air pollution sensors have led to a new wave of low-cost measurement systems that can be deployed in dense networks to capture small-scale spatio-temporal variations in ozone, a pollutant known to cause negative human health impacts. This study deployed a network of seven low-cost ozone metal oxide sensor systems (UPods) in both an open space and an urban location in Boulder, Colorado during June and July of 2015, to quantify ozone variations on spatial scales ranging from 12 m between UPods to 6.7 km between open space and urban measurement sites with a measurement uncertainty of ~5 ppb. The results showed spatial variability of ozone at both deployment sites, with the largest differences between UPod measurements occurring during the afternoons. The peak median hourly difference between UPods was 6 ppb at 1:00 p.m. at the open space site, and 11 ppb at 4:00 p.m. at the urban site. Overall, the urban ozone measurements were higher than in the open space measurements. This study evaluates the effectiveness of using low-cost sensors to capture microscale spatial and temporal variation of ozone; additionally, it highlights the importance of field calibrations and measurement uncertainty quantification when deploying low-cost sensors.
- Open Access
- 7 August 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-30
Intra-urban spatial variability of surface ozone and carbon dioxide in Riverside, CA: viability and validation of low-cost sensors
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere such as ozone and carbon dioxide. This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 and CO2 in a 314 km2 area of Riverside County near Los Angeles, California. This tool provides low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 and CO2 measurements to minute resolution reference observations resulted in R-squared and root mean squared errors (RMSE) of 0.95–0.97 and 4.4–7.2 ppbv for O3 and 0.79 and 15 ppmv CO2, respectively. Using the deployment data, ozone and carbon dioxide concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R-squared values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppb for the ozone deployment. For carbon dioxide, distributions of all measurements vary from 413–425 ppm during the calibration (collocation) and 406–472 during the deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values for ozone and carbon dioxide, we can conclude that there is spatial variability in these pollutants across the study area. This is important because it means that citizens may be exposed to more ozone than they would assume based on current regulatory monitoring.
- 7 August 2017
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-30
Open AccessIntra-urban spatial variability of surface ozone and carbon dioxide in Riverside, CA: viability and validation of low-cost sensors
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere such as ozone and carbon dioxide. This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 and CO2 in a 314 km2 area of Riverside County near Los Angeles, California. This tool provides low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 and CO2 measurements to minute resolution reference observations resulted in R-squared and root mean squared errors (RMSE) of 0.95–0.97 and 4.4–7.2 ppbv for O3 and 0.79 and 15 ppmv CO2, respectively. Using the deployment data, ozone and carbon dioxide concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R-squared values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppb for the ozone deployment. For carbon dioxide, distributions of all measurements vary from 413–425 ppm during the calibration (collocation) and 406–472 during the deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values for ozone and carbon dioxide, we can conclude that there is spatial variability in these pollutants across the study area. This is important because it means that citizens may be exposed to more ozone than they would assume based on current regulatory monitoring.