Intra-urban spatial variability of surface ozone and carbon dioxide in Riverside, CA: viability and validation of low-cost sensors
Authors:
Preprint
- 7 August 2017
- preprint
- Published by Copernicus GmbH in EGUsphere
- Vol. 2017, 1-30
Abstract
Sensor networks are being more widely used to characterize and understand compounds in the atmosphere such as ozone and carbon dioxide. This study employs a measurement tool, called the U-Pod, constructed at the University of Colorado Boulder, to investigate spatial and temporal variability of O3 and CO2 in a 314 km2 area of Riverside County near Los Angeles, California. This tool provides low-cost sensors to collect ambient data at non-permanent locations. The U-Pods were calibrated using a pre-deployment field calibration technique; all the U-Pods were collocated with regulatory monitors. After collocation, the U-Pods were deployed in the area mentioned. A subset of pods was deployed at two local regulatory air quality monitoring stations providing validation for the collocation calibration method. Field validation of sensor O3 and CO2 measurements to minute resolution reference observations resulted in R-squared and root mean squared errors (RMSE) of 0.95–0.97 and 4.4–7.2 ppbv for O3 and 0.79 and 15 ppmv CO2, respectively. Using the deployment data, ozone and carbon dioxide concentrations were observed to vary on this small spatial scale. In the analysis based on hourly binned data, the median R-squared values between all possible U-Pod pairs varied from 0.52 to 0.86 for ozone during the deployment. The medians of absolute differences were calculated between all possible pod pairs, 21 pairs total. The median values of those median absolute differences for each hour of the day varied between 2.2 and 9.3 ppb for the ozone deployment. For carbon dioxide, distributions of all measurements vary from 413–425 ppm during the calibration (collocation) and 406–472 during the deployment. Since median differences between U-Pod concentrations during deployment are larger than the respective root mean square error values for ozone and carbon dioxide, we can conclude that there is spatial variability in these pollutants across the study area. This is important because it means that citizens may be exposed to more ozone than they would assume based on current regulatory monitoring.Keywords
All Related Versions
- Published version: Atmospheric Measurement Techniques, 11 (3), 1777.
Funding Information
- Division of Computing and Communication Foundations (1442971)
This publication has 20 references indexed in Scilit:
- The rise of low-cost sensing for managing air pollution in citiesEnvironment International, 2015
- Evaluation and calibration of Aeroqual series 500 portable gas sensors for accurate measurement of ambient ozone and nitrogen dioxideAtmospheric Environment, 2015
- On the feasibility of measuring urban air pollution by wireless distributed sensor networksScience of The Total Environment, 2015
- Urbanization and the carbon cycle: Current capabilities and research outlook from the natural sciences perspectiveEarth's Future, 2014
- Spatial and temporal variability of air pollution in Birmingham, AlabamaAtmospheric Environment, 2014
- The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networksAtmospheric Environment, 2013
- Surface observations for monitoring urban fossil fuel CO2 emissions: Minimum site location requirements for the Los Angeles megacityJournal of Geophysical Research: Atmospheres, 2013
- Day of week effects on diurnal ozone/NOx cycles and transportation emissions in Southern CaliforniaTransportation Research Part D: Transport and Environment, 2007
- Metal oxides for solid-state gas sensors: What determines our choice?Materials Science and Engineering: B, 2007
- The impact of rush hour traffic and mix on the ozone weekend effect in southern CaliforniaTransportation Research Part D: Transport and Environment, 2007