Nordiana Azlin Othman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nordiana Azlin Othman has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Faridah Hanim
University Tun Hussein Onn Malaysia
2 shared publications - Matiullah Ahsan
University Tun Hussein Onn Malaysia
2 shared publications - Mohd Fairouz Mohd Yousof
University Tun Hussein Onn Malaysia
2 shared publications - Muhammad Saufi Kamarudin
University Tun Hussein Onn Malaysia
2 shared publications - Nor Ramdon Baharom
University Tun Hussein Onn Malaysia
2 shared publications - Rahisham Abdul Rahman
Universiti Tun Hussein Onn Malaysia (UTHM)
2 shared publications
Latest Publications
- Open Access
- 27 March 2026
- Published by Penteract Technology in Malaysian Journal of Science and Advanced Technology
- p. 41-48
Effect of Charge Existence on Electric Field Distribution in String Insulator
The charge existence at any region of insulator sting will distort the original electric field distribution and may result in the enhancement of local electric fields to the highest level over a long period of time. This situation would then lead to the occurrence of partial discharge and further cause premature failure of insulating material due to degradation process which can lead to electrical breakdowns and electrostatic discharges. Therefore, this paper investigates the effect of charge existence on the electric field distribution along glass insulator string. The measurement of charge distribution was experimentally collected using charge sensors to be applied in the simulation modelling. Finite element software was also adopted in this paper to assess the effect of charge existence on electric field distribution. It is found that the charge distribution is successfully collected with negative charge distribution pattern is obtained. It is proven that the value of charge collected in the experimental works indeed affects the distribution of electric field when the insulator is injected with that value. Also, it was found that the negative charge has more impact toward the electric field distribution compared with positive charge. The findings suggest that the existence of charge on the surface of insulator is certainly affect the local distribution which after a long period of time may affect the high voltage insulation performance and finally may threaten the reliability of power system network.
- 27 March 2026
- Published by Penteract Technology in Malaysian Journal of Science and Advanced Technology
- p. 41-48
Open AccessEffect of Charge Existence on Electric Field Distribution in String Insulator
The charge existence at any region of insulator sting will distort the original electric field distribution and may result in the enhancement of local electric fields to the highest level over a long period of time. This situation would then lead to the occurrence of partial discharge and further cause premature failure of insulating material due to degradation process which can lead to electrical breakdowns and electrostatic discharges. Therefore, this paper investigates the effect of charge existence on the electric field distribution along glass insulator string. The measurement of charge distribution was experimentally collected using charge sensors to be applied in the simulation modelling. Finite element software was also adopted in this paper to assess the effect of charge existence on electric field distribution. It is found that the charge distribution is successfully collected with negative charge distribution pattern is obtained. It is proven that the value of charge collected in the experimental works indeed affects the distribution of electric field when the insulator is injected with that value. Also, it was found that the negative charge has more impact toward the electric field distribution compared with positive charge. The findings suggest that the existence of charge on the surface of insulator is certainly affect the local distribution which after a long period of time may affect the high voltage insulation performance and finally may threaten the reliability of power system network.
- Open Access
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 76-88
Transmission line sag and magnetic field analysis with sag parabolic equations and Biot-Savart law
This study presents a novel approach to enhance the precision of calculating sag and magnetic fields beneath overhead transmission lines. The Biot-Savart law is integrated with parabolic equations to assign multiple magnetic field sources to each conductor, resulting in improved prediction accuracy. Addressing oversimplifications in traditional models improves the analysis of transmission lines in real-world scenarios. An analysis was performed using MATLAB and Simulink to validate the effectiveness and broad applicability of different configurations. The results demonstrated a significant improvement in precision compared to traditional methods, indicating that this approach has the potential to establish new benchmarks in the field. This methodology makes significant contributions to electromagnetic studies, offering engineers a reliable tool for designing transmission systems that are both safer and more efficient. This advancement in electrical engineering greatly improves transmission network performance by enhancing sag and magnetic field prediction accuracy. This aids in better maintenance planning and reduces outage risks, resulting in more efficient operations and improved overall performance.
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 76-88
Open AccessTransmission line sag and magnetic field analysis with sag parabolic equations and Biot-Savart law
This study presents a novel approach to enhance the precision of calculating sag and magnetic fields beneath overhead transmission lines. The Biot-Savart law is integrated with parabolic equations to assign multiple magnetic field sources to each conductor, resulting in improved prediction accuracy. Addressing oversimplifications in traditional models improves the analysis of transmission lines in real-world scenarios. An analysis was performed using MATLAB and Simulink to validate the effectiveness and broad applicability of different configurations. The results demonstrated a significant improvement in precision compared to traditional methods, indicating that this approach has the potential to establish new benchmarks in the field. This methodology makes significant contributions to electromagnetic studies, offering engineers a reliable tool for designing transmission systems that are both safer and more efficient. This advancement in electrical engineering greatly improves transmission network performance by enhancing sag and magnetic field prediction accuracy. This aids in better maintenance planning and reduces outage risks, resulting in more efficient operations and improved overall performance.
- Open Access
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 36 (1) , 53-63
Improving magnetic fields in overhead transmission lines using the insulated cross-arm method
This research study evaluates the effectiveness of the insulated cross-arm (ICA) method in reducing magnetic field (MF) levels in transmission lines. Using Ansys Maxwell finite element method (FEM) software, the study models and analyses the MF distribution in 132 kV and 275 kV overhead transmission lines (OTLs) in Malaysia. The findings reveal that implementing the ICA method can substantially reduce MF levels, improving MF performance by 36% (at 132 kV) and 48% (at 275 kV). These findings have important implications for mitigating potential health risks associated with high MF exposure near transmission lines. Furthermore, the study highlights the potential for future enhancements in ampacity and emphasizes the importance of promoting a health-conscious environment. Field studies, assessments, and investigations into economic feasibility and practical implementation are recommended for further validation and application of the ICA method. Overall, this research study contributes to the knowledge and understanding of reducing MF exposure and improving the efficiency of power transmission systems.
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 36 (1) , 53-63
Open AccessImproving magnetic fields in overhead transmission lines using the insulated cross-arm method
This research study evaluates the effectiveness of the insulated cross-arm (ICA) method in reducing magnetic field (MF) levels in transmission lines. Using Ansys Maxwell finite element method (FEM) software, the study models and analyses the MF distribution in 132 kV and 275 kV overhead transmission lines (OTLs) in Malaysia. The findings reveal that implementing the ICA method can substantially reduce MF levels, improving MF performance by 36% (at 132 kV) and 48% (at 275 kV). These findings have important implications for mitigating potential health risks associated with high MF exposure near transmission lines. Furthermore, the study highlights the potential for future enhancements in ampacity and emphasizes the importance of promoting a health-conscious environment. Field studies, assessments, and investigations into economic feasibility and practical implementation are recommended for further validation and application of the ICA method. Overall, this research study contributes to the knowledge and understanding of reducing MF exposure and improving the efficiency of power transmission systems.
- 1 August 2014
- Published by Elsevier in Journal of Electrostatics
- Vol. 72 (4) , 315-321
Characterization of charge distribution on the high voltage glass insulator string
- 1 August 2014
- Published by Elsevier in Journal of Electrostatics
- Vol. 72 (4) , 315-321
Characterization of charge distribution on the high voltage glass insulator string
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 116-120
Simulation of voltage and electric-field distribution for contaminated glass insulator
Overhead transmission line insulators are designed to perform dual functions namely electrical protection and mechanical support. However, irregular distribution of voltage and electric-field in the insulators may lead to corona, partial discharge, premature aging and indeed flashover. An attempt has been made with finite element software to calculate the voltage and electric-field distribution in this paper. QuickField™ Professional software is adopted to simulate the distribution of voltage and electric-field along the insulator surface with and without the presence of contaminants. Glass insulator, particularly cap and pin insulator is taken as main research object. The result shows that the contaminated insulator distorts the distribution of voltage and electric-field significantly. Therefore, vital to study both voltage and electric field distribution as it is valuable for designing insulator as well as to predict the performance of the insulator under contaminated conditions.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 116-120
Simulation of voltage and electric-field distribution for contaminated glass insulator
Overhead transmission line insulators are designed to perform dual functions namely electrical protection and mechanical support. However, irregular distribution of voltage and electric-field in the insulators may lead to corona, partial discharge, premature aging and indeed flashover. An attempt has been made with finite element software to calculate the voltage and electric-field distribution in this paper. QuickField™ Professional software is adopted to simulate the distribution of voltage and electric-field along the insulator surface with and without the presence of contaminants. Glass insulator, particularly cap and pin insulator is taken as main research object. The result shows that the contaminated insulator distorts the distribution of voltage and electric-field significantly. Therefore, vital to study both voltage and electric field distribution as it is valuable for designing insulator as well as to predict the performance of the insulator under contaminated conditions.