Fault Tolerance Analysis of Five-Level Neutral-Point-Clamped Inverters under Clamping Diode Open-Circuit Failure
Open Access
- 3 May 2022
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 11 (9) , 1461
Abstract
Multilevel inverters are increasingly used in industrial applications in which service continuity is crucial. This paper presents an original approach to ensure the fault-tolerant operation of neutral-point-clamped (NPC) inverters in the case of an open-circuit fault event in a clamping diode, which is rarely investigated in the conducted research work. The proposed fault-tolerant strategy meets the following criteria: restoring rated output voltage and current during post-fault operation, realizing fault-tolerant operation without additional components, maintaining rated total harmonic distortion (THD) during fault-tolerant operation, and fast transition between faulty operation and remedial operation. In the proposed approach, prior to applying the appropriate remedial action, identification of the defective clamping diode is required. In this respect, a very fast and simple logic-based fault diagnosis is presented whose implementation does not need any additional components and external circuit. Moreover, it does not require any component modeling and complicated calculations. The proposed strategy is validated by simulation and experimentation.Keywords
Funding Information
- the Scientific and Technologique Cooperation Service of the French Embassy in Tehran
This publication has 21 references indexed in Scilit:
- Method to diagnose open‐circuit faults in active power switches and clamp‐diodes of three‐level neutral‐point clamped invertersIET Electric Power Applications, 2016
- Open-Circuit Fault Diagnosis and Fault-Tolerant Control for a Grid-Connected NPC InverterIEEE Transactions on Power Electronics, 2015
- Open-Circuit Fault-Tolerant Control for Outer Switches of Three-Level Rectifiers in Wind Turbine SystemsIEEE Transactions on Power Electronics, 2015
- A Fault-Tolerant Single-Phase Five-Level Inverter for Grid-Independent PV SystemsIEEE Transactions on Industrial Electronics, 2015
- Open-Switch Fault Tolerance Control for a Three-Level NPC/T-Type Rectifier in Wind Turbine SystemsIEEE Transactions on Industrial Electronics, 2014
- Real-Time IGBT Open-Circuit Fault Diagnosis in Three-Level Neutral-Point-Clamped Voltage-Source Rectifiers Based on Instant Voltage ErrorIEEE Transactions on Industrial Electronics, 2014
- Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine SystemsIEEE Transactions on Industry Applications, 2014
- Fault diagnostic algorithm for three‐level neutral point clamped AC motor drives, based on the average current Park's vectorIET Power Electronics, 2014
- Strategies of fault tolerant operation for three-level PWM invertersIEEE Transactions on Power Electronics, 2006
- Multilevel inverters: a survey of topologies, controls, and applicationsIEEE Transactions on Industrial Electronics, 2002