Shahrokh Saadate
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shahrokh Saadate has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Philippe Poure
Université de Lorraine, CNRS, IJL, F-54000 Nancy, France
21 shared publications Philippe Poure
Institute Jean Lamour (UMR7198), Université de Lorraine, Nancy, France
19 shared publicationsP. Poure
Laboratoire d'Instrumentation Electronique de Nancy, LIEN, EA 3440, Université Henri Poincaré de Nancy I, BP 239, 54506 Vandoeuvre les Nancy cedex France
12 shared publicationsShahram Karimi
Institute for Energy and Hydro Technology, Kermanshah, Iran
10 shared publicationsArnaud Gaillard
5 shared publicationsA. Abbaspour-Tehrani-Fard
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
4 shared publications
Latest Publications
- 2 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 3543-3551
Switch Fault Detection and Localization for T-Type Converter
Over the past decade, multilevel converters have received considerable interest in medium voltage applications. A large number of active switches in a multilevel converter increases the probability of switch failure and decreases the reliability of the system. An open switch fault can lead to a malfunction of the whole system and should be diagnosed as soon as possible. In this paper, an open-switch fault diagnosis method for a five-level H-Bridge T-type converter is presented. The proposed fault detection method and the fault localization algorithm are based on the switching patterns and the converter output voltage level observation. This approach is capable to detect and localize an open circuit fault for all switches. First, it is validated by simulations in Matlab Simulink and Simscape toolbox environments. Experimental results are also presented and discussed to validate the simulation results.
- 2 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 3543-3551
Switch Fault Detection and Localization for T-Type Converter
Over the past decade, multilevel converters have received considerable interest in medium voltage applications. A large number of active switches in a multilevel converter increases the probability of switch failure and decreases the reliability of the system. An open switch fault can lead to a malfunction of the whole system and should be diagnosed as soon as possible. In this paper, an open-switch fault diagnosis method for a five-level H-Bridge T-type converter is presented. The proposed fault detection method and the fault localization algorithm are based on the switching patterns and the converter output voltage level observation. This approach is capable to detect and localize an open circuit fault for all switches. First, it is validated by simulations in Matlab Simulink and Simscape toolbox environments. Experimental results are also presented and discussed to validate the simulation results.
- Open Access
- 3 May 2022
- Published by MDPI AG in Electronics
- Vol. 11 (9) , 1461
Fault Tolerance Analysis of Five-Level Neutral-Point-Clamped Inverters under Clamping Diode Open-Circuit Failure
Multilevel inverters are increasingly used in industrial applications in which service continuity is crucial. This paper presents an original approach to ensure the fault-tolerant operation of neutral-point-clamped (NPC) inverters in the case of an open-circuit fault event in a clamping diode, which is rarely investigated in the conducted research work. The proposed fault-tolerant strategy meets the following criteria: restoring rated output voltage and current during post-fault operation, realizing fault-tolerant operation without additional components, maintaining rated total harmonic distortion (THD) during fault-tolerant operation, and fast transition between faulty operation and remedial operation. In the proposed approach, prior to applying the appropriate remedial action, identification of the defective clamping diode is required. In this respect, a very fast and simple logic-based fault diagnosis is presented whose implementation does not need any additional components and external circuit. Moreover, it does not require any component modeling and complicated calculations. The proposed strategy is validated by simulation and experimentation.
- 3 May 2022
- Published by MDPI AG in Electronics
- Vol. 11 (9) , 1461
Open AccessFault Tolerance Analysis of Five-Level Neutral-Point-Clamped Inverters under Clamping Diode Open-Circuit Failure
Multilevel inverters are increasingly used in industrial applications in which service continuity is crucial. This paper presents an original approach to ensure the fault-tolerant operation of neutral-point-clamped (NPC) inverters in the case of an open-circuit fault event in a clamping diode, which is rarely investigated in the conducted research work. The proposed fault-tolerant strategy meets the following criteria: restoring rated output voltage and current during post-fault operation, realizing fault-tolerant operation without additional components, maintaining rated total harmonic distortion (THD) during fault-tolerant operation, and fast transition between faulty operation and remedial operation. In the proposed approach, prior to applying the appropriate remedial action, identification of the defective clamping diode is required. In this respect, a very fast and simple logic-based fault diagnosis is presented whose implementation does not need any additional components and external circuit. Moreover, it does not require any component modeling and complicated calculations. The proposed strategy is validated by simulation and experimentation.
- Open Access
- 2 October 2021
- Published by MDPI AG in Electronics
- Vol. 10 (19) , 2411
A Remedial Control for Short-Circuit Fault in NPC/H-Bridge Inverters without Redundant Component
In this paper, a five-level neutral-point-clamped (NPC) inverter with short-circuit fault-tolerant capability is presented. Based on the proposed approach, in order to ensure service continuity subsequent to a short-circuit fault event in a switch, two steps are carried out. First of all, destructive consequences arising from short-circuit fault in a power switch is prevented. Afterwards, according to the defected component, remedial actions are taken. The proposed strategy does not require any redundant component. The service continuity is acquired by applying a remedial control and modifying switching commands applied to the power switches. Using the proposed approach helps to restore the rated voltage and rated current at the terminal, and there is no limit for modulation index during fault-tolerant operation under remedial control. Furthermore, compared to healthy operation, harmonic content of the terminal voltage and current is not deteriorated during fault-tolerant operation. Moreover, additional components, such as bidirectional switches and contactors, are not employed in this strategy. Only some fast fuses are placed in the converter circuit for protection purposes which do not impose a noticeable cost compared to the bidirectional switches and contactors.
- 2 October 2021
- Published by MDPI AG in Electronics
- Vol. 10 (19) , 2411
Open AccessA Remedial Control for Short-Circuit Fault in NPC/H-Bridge Inverters without Redundant Component
In this paper, a five-level neutral-point-clamped (NPC) inverter with short-circuit fault-tolerant capability is presented. Based on the proposed approach, in order to ensure service continuity subsequent to a short-circuit fault event in a switch, two steps are carried out. First of all, destructive consequences arising from short-circuit fault in a power switch is prevented. Afterwards, according to the defected component, remedial actions are taken. The proposed strategy does not require any redundant component. The service continuity is acquired by applying a remedial control and modifying switching commands applied to the power switches. Using the proposed approach helps to restore the rated voltage and rated current at the terminal, and there is no limit for modulation index during fault-tolerant operation under remedial control. Furthermore, compared to healthy operation, harmonic content of the terminal voltage and current is not deteriorated during fault-tolerant operation. Moreover, additional components, such as bidirectional switches and contactors, are not employed in this strategy. Only some fast fuses are placed in the converter circuit for protection purposes which do not impose a noticeable cost compared to the bidirectional switches and contactors.
- Open Access
- 1 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 17 (2) , 1100-1110
A Real-Time Fault Diagnosis for Neutral-Point-Clamped Inverters Based on Failure-Mode Algorithm
Fault diagnosis in multilevel converters is of great importance since they are comprised of more solid-state switches, compared to the conventional two-level converters. This paper proposes a fast and efficient real time open-switch fault diagnosis, based on failure mode algorithm for a single-phase five-level neutral-point-clamped inverter. Component modeling and complicated calculations are avoided and load parameters are not required for realizing the proposed approach. Furthermore, the proposed strategy does not require any extra sensor. The signals already available in the control system such as the applied switching pattern and terminal voltage fulfill the fault diagnosis. Thanks to the proposed fault detection strategy, any misdiagnosis arising from noise existence, response time of the sensors, turn on and turn off delay times of the power switches and measurement errors is avoided. The simulations and experiments are carried out to confirm the performance and effectiveness of the presented strategy.
- 1 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 17 (2) , 1100-1110
Open AccessA Real-Time Fault Diagnosis for Neutral-Point-Clamped Inverters Based on Failure-Mode Algorithm
Fault diagnosis in multilevel converters is of great importance since they are comprised of more solid-state switches, compared to the conventional two-level converters. This paper proposes a fast and efficient real time open-switch fault diagnosis, based on failure mode algorithm for a single-phase five-level neutral-point-clamped inverter. Component modeling and complicated calculations are avoided and load parameters are not required for realizing the proposed approach. Furthermore, the proposed strategy does not require any extra sensor. The signals already available in the control system such as the applied switching pattern and terminal voltage fulfill the fault diagnosis. Thanks to the proposed fault detection strategy, any misdiagnosis arising from noise existence, response time of the sensors, turn on and turn off delay times of the power switches and measurement errors is avoided. The simulations and experiments are carried out to confirm the performance and effectiveness of the presented strategy.
- 19 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4676-4686
Open-Switch and Open-Clamping Diode Fault Diagnosis for Single-Phase Five-Level Neutral-Point-Clamped Inverters
In this paper, a fast and efficient open-circuit switch and clamping diode fault diagnosis for Neutral-Point-Clamped inverters is proposed. Multilevel converters employed in safety-critical applications should include fault tolerant capability, where fault diagnosis plays a vital role. The proposed fault diagnosis algorithm is based on failure mode analysis, which is a logic based approach. The required signals and measurements are available in the healthy control system. Furthermore, component modeling, load parameters and complicated calculations are not required. The fault detection and identification of the faulty switch or clamping diode are carried out based on the available data such as switching pattern and terminal voltage. Although switches are more fragile than clamping diodes, clamping diodes are also subjected to breakdown. Hence, it is also crucial to achieve a clamping diode fault diagnosis strategy. Moreover, for fault detection procedure, a voltage quantifier is proposed to avoid any misdiagnosis arising from measurement errors and voltage drop in the circuit. The simulation and experimental results are presented to validate the effectiveness of the proposed approach.
- 19 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 9 (4) , 4676-4686
Open-Switch and Open-Clamping Diode Fault Diagnosis for Single-Phase Five-Level Neutral-Point-Clamped Inverters
In this paper, a fast and efficient open-circuit switch and clamping diode fault diagnosis for Neutral-Point-Clamped inverters is proposed. Multilevel converters employed in safety-critical applications should include fault tolerant capability, where fault diagnosis plays a vital role. The proposed fault diagnosis algorithm is based on failure mode analysis, which is a logic based approach. The required signals and measurements are available in the healthy control system. Furthermore, component modeling, load parameters and complicated calculations are not required. The fault detection and identification of the faulty switch or clamping diode are carried out based on the available data such as switching pattern and terminal voltage. Although switches are more fragile than clamping diodes, clamping diodes are also subjected to breakdown. Hence, it is also crucial to achieve a clamping diode fault diagnosis strategy. Moreover, for fault detection procedure, a voltage quantifier is proposed to avoid any misdiagnosis arising from measurement errors and voltage drop in the circuit. The simulation and experimental results are presented to validate the effectiveness of the proposed approach.
- Open Access
- 23 April 2019
- Published by MDPI AG in Electronics
- Vol. 8 (4) , 454
Modulation Strategy with a Minimal Number of Commutations for a Five-Level H-Bridge NPC Inverter
In this paper, a so-called OPTimized Pulse Width Modulation (OPT-PWM) strategy with a minimal number of commutations for a multilevel converter (MC) is proposed. The principle is based on the reduction of the number of switch commutations by removing the unnecessary ones for each voltage level transition. The OPT-PWM strategy is applied to a five-level H-Bridge Neutral Point Clamped (HB-5L-NPC) inverter. A specific block based on a state machine is added to conventional modulation techniques to perform the transitions from a given voltage level to another one via the best trajectory with a minimal number of commutations. The principle of this additional block can be applied to any modulation technique. In this paper, the proposed strategy is validated first by simulation and then through experimental tests.
- 23 April 2019
- Published by MDPI AG in Electronics
- Vol. 8 (4) , 454
Open AccessModulation Strategy with a Minimal Number of Commutations for a Five-Level H-Bridge NPC Inverter
In this paper, a so-called OPTimized Pulse Width Modulation (OPT-PWM) strategy with a minimal number of commutations for a multilevel converter (MC) is proposed. The principle is based on the reduction of the number of switch commutations by removing the unnecessary ones for each voltage level transition. The OPT-PWM strategy is applied to a five-level H-Bridge Neutral Point Clamped (HB-5L-NPC) inverter. A specific block based on a state machine is added to conventional modulation techniques to perform the transitions from a given voltage level to another one via the best trajectory with a minimal number of commutations. The principle of this additional block can be applied to any modulation technique. In this paper, the proposed strategy is validated first by simulation and then through experimental tests.
- Open Access
- 5 March 2019
- Published by MDPI AG in Electronics
- Vol. 8 (3) , 293
Common Switch Fault Diagnosis for Two-Stage DC-DC Converters Used in Energy Harvesting Applications
This paper proposes a new Unified Switch Fault Diagnosis (UFD) approach for two-stage non-isolated DC-DC converters used in energy harvesting applications. The proposed UFD is compared with a switch fault diagnosis consisting of two separate fault detection algorithms, working in parallel for each converter. The proposed UFD is simpler than the two parallel fault diagnosis methods in realization. Moreover, it can detect both types of switch failures, open circuit and short circuit switch faults. It can also be used for any two-stage non-isolated DC-DC converters based on two single switch converters, no matter the converter circuits in each stage. Some selected simulation and Hardware-in-the-Loop (HIL) experimentation results confirm the validity and efficiency of the proposed UFD. Also, the proposed UFD is applied successfully for fault-tolerant operation of a buck/buck–boost two-stage converter with synchronous control and a redundant switch.
- 5 March 2019
- Published by MDPI AG in Electronics
- Vol. 8 (3) , 293
Open AccessCommon Switch Fault Diagnosis for Two-Stage DC-DC Converters Used in Energy Harvesting Applications
This paper proposes a new Unified Switch Fault Diagnosis (UFD) approach for two-stage non-isolated DC-DC converters used in energy harvesting applications. The proposed UFD is compared with a switch fault diagnosis consisting of two separate fault detection algorithms, working in parallel for each converter. The proposed UFD is simpler than the two parallel fault diagnosis methods in realization. Moreover, it can detect both types of switch failures, open circuit and short circuit switch faults. It can also be used for any two-stage non-isolated DC-DC converters based on two single switch converters, no matter the converter circuits in each stage. Some selected simulation and Hardware-in-the-Loop (HIL) experimentation results confirm the validity and efficiency of the proposed UFD. Also, the proposed UFD is applied successfully for fault-tolerant operation of a buck/buck–boost two-stage converter with synchronous control and a redundant switch.
- Open Access
- 19 December 2016
- Published by EEEIC International Publishing in Transactions on Environment and Electrical Engineering
- Vol. 2 (1)
Study by modeling and simulation of open-switch fault diagnosis for five-level converters
In this paper, an open-switch fault diagnosis method for five-level H-Bridge Neutral Point Piloted (HB-NPP) or T-type converters is proposed. While fault tolerant operation is based on three steps (fault detection, fault localization and system reconfiguration), a fast fault diagnosis, including both fault detection and localization, is mandatory to make a suitable response to an open-circuit fault in one of the switches of the converter. Furthermore, fault diagnosis is necessary in embedded and safety critical applications, to prevent further damage and perform continuity of service.In this paper, we present an open-switch fault diagnosis method, based on the switches control orders and the observation of the converter output voltage level. In five-level converters such as HB-NPP and T-type topologies, some switches are mostly 'on' at the same time. Therefore, the fault localization is quite complicated. The fault diagnosis method we proposed is capable to detect and localize an open-switch fault in all cases. Computer simulations are carried out by using Matlab Simulink and SimPowerSystem toolbox to validate the proposed approach.
- 19 December 2016
- Published by EEEIC International Publishing in Transactions on Environment and Electrical Engineering
- Vol. 2 (1)
Open AccessStudy by modeling and simulation of open-switch fault diagnosis for five-level converters
In this paper, an open-switch fault diagnosis method for five-level H-Bridge Neutral Point Piloted (HB-NPP) or T-type converters is proposed. While fault tolerant operation is based on three steps (fault detection, fault localization and system reconfiguration), a fast fault diagnosis, including both fault detection and localization, is mandatory to make a suitable response to an open-circuit fault in one of the switches of the converter. Furthermore, fault diagnosis is necessary in embedded and safety critical applications, to prevent further damage and perform continuity of service.In this paper, we present an open-switch fault diagnosis method, based on the switches control orders and the observation of the converter output voltage level. In five-level converters such as HB-NPP and T-type topologies, some switches are mostly 'on' at the same time. Therefore, the fault localization is quite complicated. The fault diagnosis method we proposed is capable to detect and localize an open-switch fault in all cases. Computer simulations are carried out by using Matlab Simulink and SimPowerSystem toolbox to validate the proposed approach.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Five-level H-bridge NPC converter control with minimum commutation
In this paper, an Optimized Pulse Width Modulation (OPT-PWM) control for a Multilevel Converter (MC) is proposed. The control principle is based on the optimization of the number of commutations. The OPT-PWM control is applied on a five-level H-Bridge Neutral Point Clamped (HB-NPC) converter. First, all of the switching states for all voltage levels are examined. Then, to perform the commutation from a voltage level to another one, all of the possible trajectories from the initial state to the final one are considered. The best of them is chosen, according to minimum number of commutations criteria. A state machine is used to realize the proposed control method. Finally, the OPT-PWM control is verified on a five-level HB-NPC and validated by simulation results.
- 1 April 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Five-level H-bridge NPC converter control with minimum commutation
In this paper, an Optimized Pulse Width Modulation (OPT-PWM) control for a Multilevel Converter (MC) is proposed. The control principle is based on the optimization of the number of commutations. The OPT-PWM control is applied on a five-level H-Bridge Neutral Point Clamped (HB-NPC) converter. First, all of the switching states for all voltage levels are examined. Then, to perform the commutation from a voltage level to another one, all of the possible trajectories from the initial state to the final one are considered. The best of them is chosen, according to minimum number of commutations criteria. A state machine is used to realize the proposed control method. Finally, the OPT-PWM control is verified on a five-level HB-NPC and validated by simulation results.
- 31 July 2013
- Published by Elsevier in Renewable Energy
- Vol. 55, 35-48
FPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy
- 31 July 2013
- Published by Elsevier in Renewable Energy
- Vol. 55, 35-48
FPGA-based reconfigurable control for switch fault tolerant operation of WECS with DFIG without redundancy