The electrochemical fabrication of Ag nanoparticles decorated poly(l-cysteine) modifed electrode for non-enzymatic H2O2 sensor
Open Access
- 15 April 2025
- journal article
- research article
- Published by Springer Nature in Applied Physics A
- Vol. 131 (5) , 1-9
Abstract
In this study, Ag nanoparticles decorated poly(l-cysteine) (PCs) electrodes (Ag@PCs) were developed for the non-enzymatic determination of H2O2. Additionally, the electrochemical synthesis of Ag@PCs nanostructures on the pencil graphite electrode surface was achieved for the first time. Different techniques such as X-ray diffraction, X-ray photoelectron spectroscopy, Raman spectroscopy, and field emission scanning electron microscopy were used in the analytical and morphological characterization of the produced Ag@PCs modified electrodes. As-prepared Ag@PCs electrodes were examined as electrode materials in the non-enzymatic determination of H2O2. Electrochemical determination of H2O2 was investigated using cyclic voltammetry and chronoamperometry techniques. While the detection limit of the sensor was 0.26 µM, its sensitivity and linear range were calculated as 142.47 μA μM−1 and 250−3560 µM, respectively. Moreover, high selectivity towards H2O2 was achieved in the presence of interfering species at the Ag@PCs electrode. Ag@PCs electrodes have great potential for applications involving the electrochemical detection of H2O2.Keywords
Funding Information
- Atatürk University
This publication has 49 references indexed in Scilit:
- Multi-metal Nanozyme Properties for Colorimetric Peroxidase Reaction: Overview of an Applicable Method Validation for H2O2 DetectionJournal of Inorganic and Organometallic Polymers and Materials, 2023
- CNTs/Graphene Oxide‐Nickel Phosphate Nanocomposite‐Based Electrochemical Sensor for Detecting H 2 O 2 in Human SerumChemistrySelect, 2023
- High-performance liquid chromatography using diode array detector and fluorescence detector for hydrogen peroxide analysis in processed fishery foodsFood Science and Biotechnology, 2022
- A New Redox Mediator (Cupric‐Neocuproine Complex)‐ Modified Pencil Graphite Electrode for the Electrocatalytic Oxidation of H 2 O 2 : A Flow Injection Amperometric SensorChemElectroChem, 2019
- Non‐Enzymatic Amperometric Detection of H 2 O 2 on One‐Step Electrochemical Fabricated Cu 2 O/Electrochemically Reduced Graphene Oxide NanocompositeChemistrySelect, 2019
- An Enzyme‐free H2O2 Sensor Based on Poly(2‐Aminophenylbenzimidazole)/Gold Nanoparticles Coated Pencil Graphite ElectrodeElectroanalysis, 2018
- Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite ElectrodeElectroanalysis, 2017
- Sensitive determination of hydrogen peroxide based on a novel nonenzymatic electrochemical sensor: silver nanoparticles decorated on nanodiamondsJournal of the Iranian Chemical Society, 2015
- Advances in enzyme-free electrochemical sensors for hydrogen peroxide, glucose, and uric acidMicrochimica Acta, 2013
- Nanomolar amperometric sensing of hydrogen peroxide using a graphite pencil electrode modified with palladium nanoparticlesMicrochimica Acta, 2013