Safety and feasibility of 3D‐electroanatomical mapping‐guided zero or near‐zero fluoroscopy catheter ablation for pediatric arrhythmias: Meta‐analysis
Authors:
- Gusti Ngurah Prana JagannathaGJGusti Ngurah Prana Jagannatha
- I. Made Putra Swi AntaraIAI. Made Putra Swi Antara
- Anastasya Maria KosasihAKAnastasya Maria Kosasih
- Jonathan AdrianJAJonathan Adrian
- Brian MendelBMBrian Mendel
- Nikita Pratama Toding LabiNLNikita Pratama Toding Labi
- Bryan Gervais de LiyisBLBryan Gervais de Liyis
- Alif Hakim AlamsyahAAAlif Hakim Alamsyah
Open Access
- 16 May 2024
- journal article
- research article
- Published by Wiley in Journal of Arrhythmia
- Vol. 40 (4) , 913-934
Abstract
Background: Catheter ablation in the pediatric population using fluoroscopy has been known to cause adverse events. This study aims to assess the effectiveness and safety of zero fluoroscopy (ZF) and near‐ZF‐guided catheter ablation for the treatment of arrhythmias in the pediatric population.Methods: The PubMed, Embase, and Cochrane library databases were searched and reviewed for relevant studies. Outcomes of interest include safety, short‐term, and long‐term effectiveness. We classified patients ≤21 years old who underwent ZF or near‐ZF ablation with fluoroscopy time ≤1.5 min as our study group and patients within the same age range who underwent conventional fluoroscopy and/or near‐ZF ablation with a mean fluoroscopy time >1.5 min as our control group. Both ZF and near‐ZF ablation utilized 3D‐electroanatomical mapping (3D‐EAM).Results: Ten studies composed of 2279 patients were included in this study. Total fluoroscopy time (MD –15.93 min, 95% CI (−22.57 – (−9.29), p < .001; I2 = 84%)) and total procedural time (MD –22.06 min, 95% CI (−44.39 – (−0.28), p < .001; I2 = 88%)) were significantly lower in the near‐ZF group. Both ZF and near‐ZF demonstrated a trend towards improved success rates compared to conventional fluoroscopy but did not achieve statistical significance for all subgroup analyses. Ablation in the study group also decreased incidence of complication compared to the control (RR 0.35; 95% CI (0.14–0.90); p = .03; I2 = 0%).Conclusion: ZF and near‐ZF ablation reduced the overall duration, compares in effectiveness, and shows a superior safety profile compared to control group.Keywords
This publication has 53 references indexed in Scilit:
- 2019 APHRS expert consensus statement on three‐dimensional mapping systems for tachycardia developed in collaboration with HRS, EHRA, and LAHRSJournal of Arrhythmia, 2020
- 2018 ACC/HRS/NASCI/SCAI/SCCT Expert Consensus Document on Optimal Use of Ionizing Radiation in Cardiovascular Imaging: Best Practices for Safety and EffectivenessJACC, 2018
- Radiofrequency catheter ablation of atrioventricular node reentrant tachycardia in children with limited fluoroscopyInternational Journal of Cardiology, 2017
- Meta-Analysis of Zero or Near-Zero Fluoroscopy Use During Ablation of Cardiac ArrhythmiasThe American Journal of Cardiology, 2016
- PACES/HRS expert consensus statement on the use of catheter ablation in children and patients with congenital heart diseaseHeart Rhythm, 2016
- Near-zero x-ray in arrhythmia ablation using a 3-dimensional electroanatomic mapping system: A multicenter experienceHeart Rhythm, 2016
- Epicardial left atrial appendage and biatrial appendage accessory pathwaysHeart Rhythm, 2010
- Safety and feasibility of catheter ablation for atrioventricular nodal re-entrant tachycardia without fluoroscopic guidanceHeart Rhythm, 2009
- Transcatheter cryoablation of tachyarrhythmias in childrenJACC, 2005
- Utility of adenosine 5′-triphosphate in predicting early recurrence after successful ablation of manifest accessory pathwaysHeart Rhythm, 2004