NLNikita Pratama Toding Labi

Nikita Pratama Toding Labi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikita Pratama Toding Labi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long‐term outcomes of ventricular tachycardia ablation in repaired tetralogy of Fallot: Systematic review and meta‐analysis

    by Gusti Ngurah Prana Jagannatha, Brian Mendel, Nikita Pratama Toding Labi, Wingga Chrisna Aji, Anastasya Maria Kosasih, Jonathan Adrian, Bryan Gervais de Liyis, Putu Febry Krisna Pertiwi, I Made Putra Swi Antara

    Background: Ventricular tachycardia (VT) remains a risk in repaired Tetralogy of Fallot (rTOF); however, long‐term benefits of VT ablation have not been established. This study compares the outcomes of rTOF patients with and without VT ablation.Methods: We searched multiple databases examining the outcomes of rTOF patients who had undergone VT ablation compared to those without ablation. Primary outcomes were VT recurrence, sudden cardiac death (SCD), and all‐cause mortality. Subgroup analysis was conducted based on the type of ablation (catheter and surgical). Slow‐conducting anatomical isthmus (SCAI)‐based catheter ablation (CA) was also analyzed separately. The secondary outcome was the risk factors for the pre‐ablation history of VT.Results: Fifteen cohort studies with 1459 patients were included, 21.4% exhibited VTs. SCAI was found in 30.4% of the population, with 3.7% of non‐inducible VT. Factors significantly associated with VT before ablation included a history of ventriculostomy, QRS duration ≥180 ms, fragmented QRS, moderate to severe pulmonary regurgitation, high premature ventricular contractions burden, late gadolinium enhancement, and SCAI. Ablation was only beneficial in reducing VTs recurrence in SCAI‐based CA (risk ratio (RR) 0.11; 95% CI 0.03 to 0.33. p < 0.001; I2 = 0%) with no recurrence in patients with preventive ablation (mean follow‐up time 91.14 ± 77.81 months). The outcomes of VT ablation indicated a favorable trend concerning SCD and all‐cause mortality (RR 0.49 and 0.44, respectively); however, they were statistically insignificant.Conclusions: SCAI‐based CA has significant advantages in reducing VT recurrence in rTOF patients. Risk stratification plays a key role in determining the decision to perform ablation.


  • Open Access

    Safety and feasibility of 3D‐electroanatomical mapping‐guided zero or near‐zero fluoroscopy catheter ablation for pediatric arrhythmias: Meta‐analysis

    by Gusti Ngurah Prana Jagannatha, I. Made Putra Swi Antara, Anastasya Maria Kosasih, Jonathan Adrian, Brian Mendel, Nikita Pratama Toding Labi, Wingga Chrisna Aji, Bryan Gervais de Liyis, Made Refika Widya Apsari Tangkas, Yosep Made Pius Cardia, et al.

    Background: Catheter ablation in the pediatric population using fluoroscopy has been known to cause adverse events. This study aims to assess the effectiveness and safety of zero fluoroscopy (ZF) and near‐ZF‐guided catheter ablation for the treatment of arrhythmias in the pediatric population.Methods: The PubMed, Embase, and Cochrane library databases were searched and reviewed for relevant studies. Outcomes of interest include safety, short‐term, and long‐term effectiveness. We classified patients ≤21 years old who underwent ZF or near‐ZF ablation with fluoroscopy time ≤1.5 min as our study group and patients within the same age range who underwent conventional fluoroscopy and/or near‐ZF ablation with a mean fluoroscopy time >1.5 min as our control group. Both ZF and near‐ZF ablation utilized 3D‐electroanatomical mapping (3D‐EAM).Results: Ten studies composed of 2279 patients were included in this study. Total fluoroscopy time (MD –15.93 min, 95% CI (−22.57 – (−9.29), p < .001; I2 = 84%)) and total procedural time (MD –22.06 min, 95% CI (−44.39 – (−0.28), p < .001; I2 = 88%)) were significantly lower in the near‐ZF group. Both ZF and near‐ZF demonstrated a trend towards improved success rates compared to conventional fluoroscopy but did not achieve statistical significance for all subgroup analyses. Ablation in the study group also decreased incidence of complication compared to the control (RR 0.35; 95% CI (0.14–0.90); p = .03; I2 = 0%).Conclusion: ZF and near‐ZF ablation reduced the overall duration, compares in effectiveness, and shows a superior safety profile compared to control group.


  • Open Access

    Future direction of substrate‐based catheter ablation in Brugada syndrome and other inherited primary arrhythmia syndromes: Systematic review and meta‐analysis

    by Gusti Ngurah Prana Jagannatha, I Made Putra Swi Antara, Anastasya Maria Kosasih, Bryan Gervais de Liyis, Nikita Pratama Toding Labi, Wingga Chrisna Aji, Fanny Deantri, I Made Bagus Cahya Wibawa, Jonathan Adrian

    Background: Inherited Primary Arrhythmias Syndromes (IPAS), especially Brugada syndrome (BrS), have been associated with arrhythmogenic substrates that can be targeted through ablation. This meta‐analysis evaluated the outcomes of catheter ablation (CA) in different types of IPAS based on procedural guidance and location.Methods: A systematic search was conducted across multiple databases to identify studies reporting on ventricular arrhythmia (VA) events before and after CA in IPAS, including BrS, Long‐QT syndrome (LQTS), Early repolarization syndrome (ERS), and Idiopathic ventricular fibrillation (IVF). The primary outcomes were VA recurrence and VA burden, evaluated through conditional subgroup analysis. Procedural data were collected as secondary outcomes.Results: A total of 21 studies involving 584 IPAS patients who underwent CA were included. Following a mean follow‐up duration of 33.5 months, substrate‐based ablation demonstrated efficacy in reducing VA recurrence across all types of IPAS [RR 0.23; 95% CI (0.13–0.39); p < .001; I2 = 74%]. However, activation guidance ablation was found to be effective only in IVF cases. Although recurrences still occurred, CA was successful in reducing VA burden [MD –4.70; 95% CI (−6.11–(−3.29); p < .001; I2 = 74%]. The mean size of arrhythmogenic substrate was 15.70 cm2 [95% CI (12.34–19.99 cm2)], predominantly distributed in the epicardial right ventricular outflow tract (RVOT) in BrS cases and LQTS [Proportion 0.99; 95% CI (0.96–1.00) and Proportion 0.82; 95% CI ( 0.59–1.00), respectively].Conclusion: Substrate‐based CA has demonstrated effective prevention of VA and reduction in VA burden in IPAS cases.


  • Open Access

    20 THE CLINICAL SAGA OF RENAL DENERVATION IN UNCONTROLLED HYPERTENSION: AN UPDATED META-ANALYSIS OF RANDOMIZED SHAM-CONTROLLED TRIALS

    by Nikita Pratama Toding Labi, Gusti Ngurah Prana Jagannatha, Wingga Chrisna Aji, Yusra Pintaningrum

    Background: Renal denervation (RDN) with catheter ablation has shown promising yet conflicting results in the management of uncontrolled hypertension. With the availability of recent randomized sham-controlled trials, we decided to perform an updated meta-analysis. Objective: To examine the utilization of renal denervation in patients with uncontrolled hypertension. Method: A systematic search in electronic databases was conducted. We included randomized sham-controlled trials comparing RDN and sham procedure in patients with uncontrolled hypertension. Included studies were evaluated for risk of bias. Our outcomes of interest were 24-hour ambulatory blood pressure (BP) and office BP. We performed fixed and random-effects meta-analysis using the inverse variance method to calculate the mean difference (MD) and 95% confidence interval (CI). Result: Final analysis included 10 studies with a total of 1,571 patients. With the median follow-up period of 6 months, RDN was associated with a significant decrease in 24-hour ambulatory BP (Systolic: MD -3.50 mmHg, 95% CI -4.75, -2.25, p2=0.00; Diastolic: MD -1.97 mmHg, 95% CI -2.74, -1.20, p2=0.31) compared to sham procedure. Similiarly, office BP was reduced significantly with RDN when compared to sham procedure (Systolic: MD -4.89 mmHg, 95% CI -7.67, -2.10, p=0.04, I2=0.51; Diastolic: MD -3.07 mmHg, 95% CI -4.14, -2.00, p2=0.38). Further subgroup analysis showed that radiofrequency RDN was associated with a significant reduction in both 24-hour ambulatory and office BP, while ultrasound RDN was not associated with such differences. Conclusion: This updated meta-analysis suggests that RDN is associated with statistically significant improvement in uncontrolled hypertension management.