Anastasya Maria Kosasih
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anastasya Maria Kosasih has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bryan Gervais de Liyis
Faculty of Medicine, Universitas Udayana, Denpasar, Bali, Indonesia
3 shared publications - Gusti Ngurah Prana Jagannatha
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
3 shared publications - I. Made Putra Swi Antara
Department of Cardiology and Vascular Medicine Udayana University/Prof. Dr. I.G.N.G. Ngoerah General Hospital Denpasar Bali Indonesia
3 shared publications - Jonathan Adrian
Faculty of Medicine Udayana University/Prof. dr. I.G.N.G Ngoerah General Hospital Denpasar Bali Indonesia
3 shared publications - Nikita Pratama Toding Labi
Faculty of Medicine Sam Ratulangi University Manado North Sulawesi Indonesia
3 shared publications Wingga Chrisna Aji
Faculty of Medicine Muhammadiyah Yogyakarta University Yogyakarta Indonesia
3 shared publications
Latest Publications
- Open Access
- 7 January 2026
- Published by MDPI AG in Clocks & Sleep
- Vol. 8 (1) , 4
Prevalence of Obstructive Sleep Apnea and Adherence to CPAP for TAXI Drivers
We investigated the effects of Continuous Positive Airway Pressure (CPAP) on blood pressure (BP) and vigilance in taxi drivers with obstructive sleep apnea (OSA). This pilot study recruited taxi drivers aged ≥60 years to undergo polysomnography. Those diagnosed with OSA underwent 6 months of CPAP therapy. Baseline and follow-up assessments included 24 h ambulatory blood pressure monitoring (ABPM) and the psychomotor vigilance test (PVT). Among the 32 participants, 22 (68.8%) were diagnosed with OSA (median age 63.0 [62.0–65.0] years; 21 males). The average CPAP adherence was 3.1 ± 2.3 h per night, with 23.5% using CPAP for more than 4 h per night. There were no significant changes in 24 h mean systolic ABPM (125.9 [116.8–134.9] mmHg to 126.0 [118.3–133.7] mmHg; p = 0.93) or reaction times measured by PVT (2.0 [0.0–3.0] lapses to 2.0 [1.0–3.0] lapses; p = 0.82) after CPAP therapy. A high prevalence of OSA was observed among taxi drivers. CPAP adherence was suboptimal and did not result in significant improvements in BP or vigilance.
- 7 January 2026
- Published by MDPI AG in Clocks & Sleep
- Vol. 8 (1) , 4
Open AccessPrevalence of Obstructive Sleep Apnea and Adherence to CPAP for TAXI Drivers
We investigated the effects of Continuous Positive Airway Pressure (CPAP) on blood pressure (BP) and vigilance in taxi drivers with obstructive sleep apnea (OSA). This pilot study recruited taxi drivers aged ≥60 years to undergo polysomnography. Those diagnosed with OSA underwent 6 months of CPAP therapy. Baseline and follow-up assessments included 24 h ambulatory blood pressure monitoring (ABPM) and the psychomotor vigilance test (PVT). Among the 32 participants, 22 (68.8%) were diagnosed with OSA (median age 63.0 [62.0–65.0] years; 21 males). The average CPAP adherence was 3.1 ± 2.3 h per night, with 23.5% using CPAP for more than 4 h per night. There were no significant changes in 24 h mean systolic ABPM (125.9 [116.8–134.9] mmHg to 126.0 [118.3–133.7] mmHg; p = 0.93) or reaction times measured by PVT (2.0 [0.0–3.0] lapses to 2.0 [1.0–3.0] lapses; p = 0.82) after CPAP therapy. A high prevalence of OSA was observed among taxi drivers. CPAP adherence was suboptimal and did not result in significant improvements in BP or vigilance.
- Open Access
- 2 January 2026
- Published by MDPI AG in Preprints.org
Prevalence of Obstructive Sleep Apnea and Adherence to CPAP for TAXI Drivers
Objectives: We investigated the effects of Continuous Positive Airway Pressure (CPAP) on blood pressure (BP) and vigilance in taxi drivers with obstructive sleep apnea (OSA). Methods: Taxi drivers aged ≥60 years were recruited for polysomnography. Those diagnosed with OSA underwent 6 months of CPAP therapy. Baseline and follow-up assessments included 24-hour ambulatory blood pressure monitoring (ABPM) and the psychomotor vigilance test (PVT). Results: Among the 32 participants, 22 (68.8%) were diagnosed with OSA (median age 63.0 [62.0–65.0] years; 21 males). The average CPAP adherence was 3.1±2.3 hours per night, with 23.5% using CPAP for more than 4 hours per night. There were no significant changes in 24-hour mean systolic ABPM (125.9 [116.8–134.9] mmHg to 126.0 [118.3–133.7] mmHg; p=0.93) or reaction times measured by PVT (2.0 [0.0–3.0] lapses to 2.0 [1.0–3.0] lapses; p=0.82) after CPAP therapy. Conclusion: A high prevalence of OSA was observed among taxi drivers. CPAP adherence was suboptimal and did not result in significant improvements in BP or vigilance.
- 2 January 2026
- Published by MDPI AG in Preprints.org
Open AccessPrevalence of Obstructive Sleep Apnea and Adherence to CPAP for TAXI Drivers
Objectives: We investigated the effects of Continuous Positive Airway Pressure (CPAP) on blood pressure (BP) and vigilance in taxi drivers with obstructive sleep apnea (OSA). Methods: Taxi drivers aged ≥60 years were recruited for polysomnography. Those diagnosed with OSA underwent 6 months of CPAP therapy. Baseline and follow-up assessments included 24-hour ambulatory blood pressure monitoring (ABPM) and the psychomotor vigilance test (PVT). Results: Among the 32 participants, 22 (68.8%) were diagnosed with OSA (median age 63.0 [62.0–65.0] years; 21 males). The average CPAP adherence was 3.1±2.3 hours per night, with 23.5% using CPAP for more than 4 hours per night. There were no significant changes in 24-hour mean systolic ABPM (125.9 [116.8–134.9] mmHg to 126.0 [118.3–133.7] mmHg; p=0.93) or reaction times measured by PVT (2.0 [0.0–3.0] lapses to 2.0 [1.0–3.0] lapses; p=0.82) after CPAP therapy. Conclusion: A high prevalence of OSA was observed among taxi drivers. CPAP adherence was suboptimal and did not result in significant improvements in BP or vigilance.
- Open Access
- 12 June 2024
- Published by Wiley in Journal of Arrhythmia
- Vol. 40 (4) , 935-947
Long‐term outcomes of ventricular tachycardia ablation in repaired tetralogy of Fallot: Systematic review and meta‐analysis
Background: Ventricular tachycardia (VT) remains a risk in repaired Tetralogy of Fallot (rTOF); however, long‐term benefits of VT ablation have not been established. This study compares the outcomes of rTOF patients with and without VT ablation.Methods: We searched multiple databases examining the outcomes of rTOF patients who had undergone VT ablation compared to those without ablation. Primary outcomes were VT recurrence, sudden cardiac death (SCD), and all‐cause mortality. Subgroup analysis was conducted based on the type of ablation (catheter and surgical). Slow‐conducting anatomical isthmus (SCAI)‐based catheter ablation (CA) was also analyzed separately. The secondary outcome was the risk factors for the pre‐ablation history of VT.Results: Fifteen cohort studies with 1459 patients were included, 21.4% exhibited VTs. SCAI was found in 30.4% of the population, with 3.7% of non‐inducible VT. Factors significantly associated with VT before ablation included a history of ventriculostomy, QRS duration ≥180 ms, fragmented QRS, moderate to severe pulmonary regurgitation, high premature ventricular contractions burden, late gadolinium enhancement, and SCAI. Ablation was only beneficial in reducing VTs recurrence in SCAI‐based CA (risk ratio (RR) 0.11; 95% CI 0.03 to 0.33. p < 0.001; I2 = 0%) with no recurrence in patients with preventive ablation (mean follow‐up time 91.14 ± 77.81 months). The outcomes of VT ablation indicated a favorable trend concerning SCD and all‐cause mortality (RR 0.49 and 0.44, respectively); however, they were statistically insignificant.Conclusions: SCAI‐based CA has significant advantages in reducing VT recurrence in rTOF patients. Risk stratification plays a key role in determining the decision to perform ablation.
- 12 June 2024
- Published by Wiley in Journal of Arrhythmia
- Vol. 40 (4) , 935-947
Open AccessLong‐term outcomes of ventricular tachycardia ablation in repaired tetralogy of Fallot: Systematic review and meta‐analysis
Background: Ventricular tachycardia (VT) remains a risk in repaired Tetralogy of Fallot (rTOF); however, long‐term benefits of VT ablation have not been established. This study compares the outcomes of rTOF patients with and without VT ablation.Methods: We searched multiple databases examining the outcomes of rTOF patients who had undergone VT ablation compared to those without ablation. Primary outcomes were VT recurrence, sudden cardiac death (SCD), and all‐cause mortality. Subgroup analysis was conducted based on the type of ablation (catheter and surgical). Slow‐conducting anatomical isthmus (SCAI)‐based catheter ablation (CA) was also analyzed separately. The secondary outcome was the risk factors for the pre‐ablation history of VT.Results: Fifteen cohort studies with 1459 patients were included, 21.4% exhibited VTs. SCAI was found in 30.4% of the population, with 3.7% of non‐inducible VT. Factors significantly associated with VT before ablation included a history of ventriculostomy, QRS duration ≥180 ms, fragmented QRS, moderate to severe pulmonary regurgitation, high premature ventricular contractions burden, late gadolinium enhancement, and SCAI. Ablation was only beneficial in reducing VTs recurrence in SCAI‐based CA (risk ratio (RR) 0.11; 95% CI 0.03 to 0.33. p < 0.001; I2 = 0%) with no recurrence in patients with preventive ablation (mean follow‐up time 91.14 ± 77.81 months). The outcomes of VT ablation indicated a favorable trend concerning SCD and all‐cause mortality (RR 0.49 and 0.44, respectively); however, they were statistically insignificant.Conclusions: SCAI‐based CA has significant advantages in reducing VT recurrence in rTOF patients. Risk stratification plays a key role in determining the decision to perform ablation.
- Open Access
- 16 May 2024
- Published by Wiley in Journal of Arrhythmia
- Vol. 40 (4) , 913-934
Safety and feasibility of 3D‐electroanatomical mapping‐guided zero or near‐zero fluoroscopy catheter ablation for pediatric arrhythmias: Meta‐analysis
Background: Catheter ablation in the pediatric population using fluoroscopy has been known to cause adverse events. This study aims to assess the effectiveness and safety of zero fluoroscopy (ZF) and near‐ZF‐guided catheter ablation for the treatment of arrhythmias in the pediatric population.Methods: The PubMed, Embase, and Cochrane library databases were searched and reviewed for relevant studies. Outcomes of interest include safety, short‐term, and long‐term effectiveness. We classified patients ≤21 years old who underwent ZF or near‐ZF ablation with fluoroscopy time ≤1.5 min as our study group and patients within the same age range who underwent conventional fluoroscopy and/or near‐ZF ablation with a mean fluoroscopy time >1.5 min as our control group. Both ZF and near‐ZF ablation utilized 3D‐electroanatomical mapping (3D‐EAM).Results: Ten studies composed of 2279 patients were included in this study. Total fluoroscopy time (MD –15.93 min, 95% CI (−22.57 – (−9.29), p < .001; I2 = 84%)) and total procedural time (MD –22.06 min, 95% CI (−44.39 – (−0.28), p < .001; I2 = 88%)) were significantly lower in the near‐ZF group. Both ZF and near‐ZF demonstrated a trend towards improved success rates compared to conventional fluoroscopy but did not achieve statistical significance for all subgroup analyses. Ablation in the study group also decreased incidence of complication compared to the control (RR 0.35; 95% CI (0.14–0.90); p = .03; I2 = 0%).Conclusion: ZF and near‐ZF ablation reduced the overall duration, compares in effectiveness, and shows a superior safety profile compared to control group.
- 16 May 2024
- Published by Wiley in Journal of Arrhythmia
- Vol. 40 (4) , 913-934
Open AccessSafety and feasibility of 3D‐electroanatomical mapping‐guided zero or near‐zero fluoroscopy catheter ablation for pediatric arrhythmias: Meta‐analysis
Background: Catheter ablation in the pediatric population using fluoroscopy has been known to cause adverse events. This study aims to assess the effectiveness and safety of zero fluoroscopy (ZF) and near‐ZF‐guided catheter ablation for the treatment of arrhythmias in the pediatric population.Methods: The PubMed, Embase, and Cochrane library databases were searched and reviewed for relevant studies. Outcomes of interest include safety, short‐term, and long‐term effectiveness. We classified patients ≤21 years old who underwent ZF or near‐ZF ablation with fluoroscopy time ≤1.5 min as our study group and patients within the same age range who underwent conventional fluoroscopy and/or near‐ZF ablation with a mean fluoroscopy time >1.5 min as our control group. Both ZF and near‐ZF ablation utilized 3D‐electroanatomical mapping (3D‐EAM).Results: Ten studies composed of 2279 patients were included in this study. Total fluoroscopy time (MD –15.93 min, 95% CI (−22.57 – (−9.29), p < .001; I2 = 84%)) and total procedural time (MD –22.06 min, 95% CI (−44.39 – (−0.28), p < .001; I2 = 88%)) were significantly lower in the near‐ZF group. Both ZF and near‐ZF demonstrated a trend towards improved success rates compared to conventional fluoroscopy but did not achieve statistical significance for all subgroup analyses. Ablation in the study group also decreased incidence of complication compared to the control (RR 0.35; 95% CI (0.14–0.90); p = .03; I2 = 0%).Conclusion: ZF and near‐ZF ablation reduced the overall duration, compares in effectiveness, and shows a superior safety profile compared to control group.
- Open Access
- 1 November 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (6) , 909-927
Future direction of substrate‐based catheter ablation in Brugada syndrome and other inherited primary arrhythmia syndromes: Systematic review and meta‐analysis
Background: Inherited Primary Arrhythmias Syndromes (IPAS), especially Brugada syndrome (BrS), have been associated with arrhythmogenic substrates that can be targeted through ablation. This meta‐analysis evaluated the outcomes of catheter ablation (CA) in different types of IPAS based on procedural guidance and location.Methods: A systematic search was conducted across multiple databases to identify studies reporting on ventricular arrhythmia (VA) events before and after CA in IPAS, including BrS, Long‐QT syndrome (LQTS), Early repolarization syndrome (ERS), and Idiopathic ventricular fibrillation (IVF). The primary outcomes were VA recurrence and VA burden, evaluated through conditional subgroup analysis. Procedural data were collected as secondary outcomes.Results: A total of 21 studies involving 584 IPAS patients who underwent CA were included. Following a mean follow‐up duration of 33.5 months, substrate‐based ablation demonstrated efficacy in reducing VA recurrence across all types of IPAS [RR 0.23; 95% CI (0.13–0.39); p < .001; I2 = 74%]. However, activation guidance ablation was found to be effective only in IVF cases. Although recurrences still occurred, CA was successful in reducing VA burden [MD –4.70; 95% CI (−6.11–(−3.29); p < .001; I2 = 74%]. The mean size of arrhythmogenic substrate was 15.70 cm2 [95% CI (12.34–19.99 cm2)], predominantly distributed in the epicardial right ventricular outflow tract (RVOT) in BrS cases and LQTS [Proportion 0.99; 95% CI (0.96–1.00) and Proportion 0.82; 95% CI ( 0.59–1.00), respectively].Conclusion: Substrate‐based CA has demonstrated effective prevention of VA and reduction in VA burden in IPAS cases.
- 1 November 2023
- Published by Wiley in Journal of Arrhythmia
- Vol. 39 (6) , 909-927
Open AccessFuture direction of substrate‐based catheter ablation in Brugada syndrome and other inherited primary arrhythmia syndromes: Systematic review and meta‐analysis
Background: Inherited Primary Arrhythmias Syndromes (IPAS), especially Brugada syndrome (BrS), have been associated with arrhythmogenic substrates that can be targeted through ablation. This meta‐analysis evaluated the outcomes of catheter ablation (CA) in different types of IPAS based on procedural guidance and location.Methods: A systematic search was conducted across multiple databases to identify studies reporting on ventricular arrhythmia (VA) events before and after CA in IPAS, including BrS, Long‐QT syndrome (LQTS), Early repolarization syndrome (ERS), and Idiopathic ventricular fibrillation (IVF). The primary outcomes were VA recurrence and VA burden, evaluated through conditional subgroup analysis. Procedural data were collected as secondary outcomes.Results: A total of 21 studies involving 584 IPAS patients who underwent CA were included. Following a mean follow‐up duration of 33.5 months, substrate‐based ablation demonstrated efficacy in reducing VA recurrence across all types of IPAS [RR 0.23; 95% CI (0.13–0.39); p < .001; I2 = 74%]. However, activation guidance ablation was found to be effective only in IVF cases. Although recurrences still occurred, CA was successful in reducing VA burden [MD –4.70; 95% CI (−6.11–(−3.29); p < .001; I2 = 74%]. The mean size of arrhythmogenic substrate was 15.70 cm2 [95% CI (12.34–19.99 cm2)], predominantly distributed in the epicardial right ventricular outflow tract (RVOT) in BrS cases and LQTS [Proportion 0.99; 95% CI (0.96–1.00) and Proportion 0.82; 95% CI ( 0.59–1.00), respectively].Conclusion: Substrate‐based CA has demonstrated effective prevention of VA and reduction in VA burden in IPAS cases.