Abstract
The critical properties of REBa1Cu3O7-x (REBCO, RE = Rare Earth) tapes bring essential information about the construction of high field superconducting magnets. Typically, the magnetic field dependence of the critical current (Ic) in REBCO tapes is measured under steady-state magnetic fields using direct current measurements (DCMs). However, this method becomes time-consuming and generates significant heating. Pulsed current measurements (PCMs) can reduce current duty cycles and shorten the measuring time, but the accompanying high dI/dt may introduce bias in the measurement accuracy. In this study, both direct current and pulsed current were applied on the same samples at temperatures ranging from 20 K to 77 K and magnetic fields up to 18 T (steady-state). A two-dimensional (2-D) finite-element model based on the H-formulation was developed to analyze the current responses in REBCO tapes. The loss and temperature rise were also calculated. The results show that the critical currents measured by PCM and DCM exhibit consistent temperature and magnetic-field dependence. With the Ic extracted until the voltage is stabilized (during the period of dI/dt≈0), the PCM agrees with DCM generally within 10%. The simulation demonstrates that PCM is helpful in reducing the time-averaged loss.
Funding Information
  • National Key R&D Program of China (2023YFA1607303)
  • Synergetic Extreme Condition User Facility of the Institute of Physics, Chinese Academy of Sciences

This publication has 32 references indexed in Scilit: