Hao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hao Zhang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Xiaowei Song
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications Chengzhang Guo
Wuhan National High Magnetic Field Center, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications- Jian Zhang
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
2 shared publications - Qi Yuan
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan, China
2 shared publications Ao Feng
Wuhan National High Magnetic Field Center, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publicationHe Qi
School of Electrical Engineering Southwest Jiaotong University Chengdu China
1 shared publication
Latest Publications
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4697-4706
Fast Excitation Control System Design and AC Loss Evaluation for HTS Synchronous Condenser in Renewable Energy Systems
Distributed dynamic synchronous condensers (DSCs) offer fast response and high overload capacity, making them widely used for reactive power support and inertia response in distributed renewable energy systems (DRES). A 10 Mvar-class high temperature superconducting (HTS) DSC is currently under development. To meet the grid-code requirements for fast dynamic response and enhance the transient reactive support of the HTS DSC, a fast DC excitation power topology and control method are proposed to improve its performance. A Simulink model, based on the IEEE standard four-machine two-area test system, is established to simulate five typical operating scenarios: no-load excitation, rated excitation, dynamic excitation, forced excitation, and de-excitation. The simulation results successfully verify the dynamic reactive power support capability of the 10-Mvar HTS DSC. Additionally, a 30-kW prototype of the DC exci-tation power supply is developed to experimentally validate the performance of the fast dynamic excitation system. Finally, AC losses under these five operating scenarios are calculated using a finite element method (FEM) based on the T-A formulation.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (3) , 4697-4706
Fast Excitation Control System Design and AC Loss Evaluation for HTS Synchronous Condenser in Renewable Energy Systems
Distributed dynamic synchronous condensers (DSCs) offer fast response and high overload capacity, making them widely used for reactive power support and inertia response in distributed renewable energy systems (DRES). A 10 Mvar-class high temperature superconducting (HTS) DSC is currently under development. To meet the grid-code requirements for fast dynamic response and enhance the transient reactive support of the HTS DSC, a fast DC excitation power topology and control method are proposed to improve its performance. A Simulink model, based on the IEEE standard four-machine two-area test system, is established to simulate five typical operating scenarios: no-load excitation, rated excitation, dynamic excitation, forced excitation, and de-excitation. The simulation results successfully verify the dynamic reactive power support capability of the 10-Mvar HTS DSC. Additionally, a 30-kW prototype of the DC exci-tation power supply is developed to experimentally validate the performance of the fast dynamic excitation system. Finally, AC losses under these five operating scenarios are calculated using a finite element method (FEM) based on the T-A formulation.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Development of a Critical Current Measurement Platform for REBCO Tapes with Micro-Bridges Based on High-Frequency Pulse Current Injection
The critical current (Ic) of high-temperature superconducting (HTS) tapes is typically measured under steady-state magnetic fields using DC power supply. However, such fields are generally limited below 35 T, and generating higher steady-state magnetic fields requires considerable time and resources. In contrast, pulsed-field magnets enable shorter testing time and can exceed 50 T. Thus, we developed a high-frequency pulsed current injection platform for measuring Ic of HTS tapes under pulsed magnetic fields. Additionally, etched micro-bridges were employed to proportionally reduce the applied current and mitigate thermal effects that could degrade measurement accuracy. Taking the 50 T, 100-ms flat-top pulsed magnetic fields at the Wuhan National High Magnetic Field Center (WHMFC) as a potential application scenario, the proposed platform integrates a 20 kHz / 6.5-digit multimeter and a mixed-signal oscilloscope for synchronized acquisition. We investigated the effects of injection frequencies (2 kHz to 100 Hz), magnetic fields (0 T to 2 T), and temperatures (65 K to 83 K) on platform performance. The proposed platform was further validated against the conventional DC measurement method at 77 K, self-field.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Development of a Critical Current Measurement Platform for REBCO Tapes with Micro-Bridges Based on High-Frequency Pulse Current Injection
The critical current (Ic) of high-temperature superconducting (HTS) tapes is typically measured under steady-state magnetic fields using DC power supply. However, such fields are generally limited below 35 T, and generating higher steady-state magnetic fields requires considerable time and resources. In contrast, pulsed-field magnets enable shorter testing time and can exceed 50 T. Thus, we developed a high-frequency pulsed current injection platform for measuring Ic of HTS tapes under pulsed magnetic fields. Additionally, etched micro-bridges were employed to proportionally reduce the applied current and mitigate thermal effects that could degrade measurement accuracy. Taking the 50 T, 100-ms flat-top pulsed magnetic fields at the Wuhan National High Magnetic Field Center (WHMFC) as a potential application scenario, the proposed platform integrates a 20 kHz / 6.5-digit multimeter and a mixed-signal oscilloscope for synchronized acquisition. We investigated the effects of injection frequencies (2 kHz to 100 Hz), magnetic fields (0 T to 2 T), and temperatures (65 K to 83 K) on platform performance. The proposed platform was further validated against the conventional DC measurement method at 77 K, self-field.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Experimental and Numerical Analysis of Critical Current Measurement of REBCO Tapes Using Pulsed and Direct Currents
The critical properties of REBa1Cu3O7-x (REBCO, RE = Rare Earth) tapes bring essential information about the construction of high field superconducting magnets. Typically, the magnetic field dependence of the critical current (Ic) in REBCO tapes is measured under steady-state magnetic fields using direct current measurements (DCMs). However, this method becomes time-consuming and generates significant heating. Pulsed current measurements (PCMs) can reduce current duty cycles and shorten the measuring time, but the accompanying high dI/dt may introduce bias in the measurement accuracy. In this study, both direct current and pulsed current were applied on the same samples at temperatures ranging from 20 K to 77 K and magnetic fields up to 18 T (steady-state). A two-dimensional (2-D) finite-element model based on the H-formulation was developed to analyze the current responses in REBCO tapes. The loss and temperature rise were also calculated. The results show that the critical currents measured by PCM and DCM exhibit consistent temperature and magnetic-field dependence. With the Ic extracted until the voltage is stabilized (during the period of dI/dt≈0), the PCM agrees with DCM generally within 10%. The simulation demonstrates that PCM is helpful in reducing the time-averaged loss.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Experimental and Numerical Analysis of Critical Current Measurement of REBCO Tapes Using Pulsed and Direct Currents
The critical properties of REBa1Cu3O7-x (REBCO, RE = Rare Earth) tapes bring essential information about the construction of high field superconducting magnets. Typically, the magnetic field dependence of the critical current (Ic) in REBCO tapes is measured under steady-state magnetic fields using direct current measurements (DCMs). However, this method becomes time-consuming and generates significant heating. Pulsed current measurements (PCMs) can reduce current duty cycles and shorten the measuring time, but the accompanying high dI/dt may introduce bias in the measurement accuracy. In this study, both direct current and pulsed current were applied on the same samples at temperatures ranging from 20 K to 77 K and magnetic fields up to 18 T (steady-state). A two-dimensional (2-D) finite-element model based on the H-formulation was developed to analyze the current responses in REBCO tapes. The loss and temperature rise were also calculated. The results show that the critical currents measured by PCM and DCM exhibit consistent temperature and magnetic-field dependence. With the Ic extracted until the voltage is stabilized (during the period of dI/dt≈0), the PCM agrees with DCM generally within 10%. The simulation demonstrates that PCM is helpful in reducing the time-averaged loss.
- Open Access
Hierarchical Operation Optimization for Regenerative Braking Energy Utilizing in Urban Rail Traction Power Supply System
The energy feedback system (EFS) is widely accepted to utilize the regenerative braking energy (RBE) in an urban rail traction power supply system (TPSS). However, the sharing relationship of RBE between EFS, traction trains and on-board braking resistors is not clear. In addition, the impact of EFS operation on the sharing of RBE has been rarely studied. This paper proposed a hierarchical operation optimization method for improving the utilization of shared RBE in TPSS through the EFS. An optimizing model for the dynamic start-up voltage threshold of EFS is established, with the objective of minimizing TPSS power consumption. A fast prediction model of train operation information is developed to analyze the steady-state power flow in advance. The optimal solution is searched using a salp swarm algorithm (SSA) on a per second basis. A microsystem of three traction stations and two trains is analyzed. Compared to the conventional constant voltage operation scheme, the optimal solution achieves a maximum additional energy-saving efficiency improvement of 2.44%. Efficient sharing of RBE is identified as the key to achieving energy savings. Regarding the local control part, system stability analysis is verified. Real-time simulation results indicate that the dynamic operating mode of EFS efficiently distributes RBE.
Open AccessHierarchical Operation Optimization for Regenerative Braking Energy Utilizing in Urban Rail Traction Power Supply System
The energy feedback system (EFS) is widely accepted to utilize the regenerative braking energy (RBE) in an urban rail traction power supply system (TPSS). However, the sharing relationship of RBE between EFS, traction trains and on-board braking resistors is not clear. In addition, the impact of EFS operation on the sharing of RBE has been rarely studied. This paper proposed a hierarchical operation optimization method for improving the utilization of shared RBE in TPSS through the EFS. An optimizing model for the dynamic start-up voltage threshold of EFS is established, with the objective of minimizing TPSS power consumption. A fast prediction model of train operation information is developed to analyze the steady-state power flow in advance. The optimal solution is searched using a salp swarm algorithm (SSA) on a per second basis. A microsystem of three traction stations and two trains is analyzed. Compared to the conventional constant voltage operation scheme, the optimal solution achieves a maximum additional energy-saving efficiency improvement of 2.44%. Efficient sharing of RBE is identified as the key to achieving energy savings. Regarding the local control part, system stability analysis is verified. Real-time simulation results indicate that the dynamic operating mode of EFS efficiently distributes RBE.
- Open Access
- 2 September 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (1) , 110-122
Modelling, simulating and parameter designing for traction power system with bidirectional converter devices
The bidirectional converter device (BCD) can substitute the substation rectifier and the energy feedback system (EFS) by transforming energy between the AC side and DC side. However, the performance of the railway system with BCDs as only converters has not been fully understood. A simulation approach is required to evaluate the system performance and guide the design. In this paper, the traction power supply system considering the capacity constraint of BCDs is modelled first, and the AC/DC power calculating algorithm is studied. A three‐layer double‐loop parameter designing strategy based on the enhanced brute force is proposed, which considers the N −1 principle. In the case study, the power source model for trains and power constraint for BCDs are verified. The boundary configuration set is obtained. The capacity of BCDs is at least 7 MW, while the slope is 0 and the no‐load voltage is between 1730 and 1750 V. Finally, compared with the system with rectifiers and EFSs, the system with BCDs has better performance, which is 46.7 V less of the rail potential, 127.8 V less of network voltage fluctuation, and 735.56 kWh per hour more of the feedback energy.
- 2 September 2021
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 16 (1) , 110-122
Open AccessModelling, simulating and parameter designing for traction power system with bidirectional converter devices
The bidirectional converter device (BCD) can substitute the substation rectifier and the energy feedback system (EFS) by transforming energy between the AC side and DC side. However, the performance of the railway system with BCDs as only converters has not been fully understood. A simulation approach is required to evaluate the system performance and guide the design. In this paper, the traction power supply system considering the capacity constraint of BCDs is modelled first, and the AC/DC power calculating algorithm is studied. A three‐layer double‐loop parameter designing strategy based on the enhanced brute force is proposed, which considers the N −1 principle. In the case study, the power source model for trains and power constraint for BCDs are verified. The boundary configuration set is obtained. The capacity of BCDs is at least 7 MW, while the slope is 0 and the no‐load voltage is between 1730 and 1750 V. Finally, compared with the system with rectifiers and EFSs, the system with BCDs has better performance, which is 46.7 V less of the rail potential, 127.8 V less of network voltage fluctuation, and 735.56 kWh per hour more of the feedback energy.