Qi Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qi Yuan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Xiaowei Song
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications Chengzhang Guo
Wuhan National High Magnetic Field Center, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications- Hao Zhang
Wuhan National High Magnetic Field Center, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Quanliang Cao
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Benzhe Zhou
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China
1 shared publication - Gang Li
Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, China
1 shared publication
Latest Publications
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (2) , 1-13
Possible Overestimation of I c Value of REBCO Tapes Due to the Narrow Bridge Fabricated by Laser Etching During Transport Measurements
Etching a narrow bridge on REBa2Cu3O7-x (REBCO, RE = Rare Earth) tape is a widely applied procedure during transport measurements of critical current (Ic), aiming to mitigate significant Lorentz forces. However, the microbridge can influence the measurement accuracy, and understanding this influence is crucial because it can bias the extrapolation of Ic to the full tape width. In this article, we reveal that the microbridge could result in an overestimation when extrapolating the full-width Ic values from microbridge ones. We identified two primary sources of this overestimation by systematically comparing the directly measured full-width Ic values with those extrapolated from narrow bridges under varying temperatures, applied magnetic fields, and field orientations. The first source arises from inaccuracies in the assumed cross-sectional geometry and area of the narrow bridge. Specifically, assuming a rectangular cross-section when the actual geometry is trapezoidal leads to significant overestimations. The second factor is the nonuniform pinning effect across the thickness of the REBCO layer. Although this effect is negligible at low magnetic fields and higher temperatures, it becomes significant at lower temperatures, high magnetic fields, and when the field is nearly parallel to the tape surface. Based on these findings, we propose an improved procedure for transport measurements using narrow bridges to achieve more accurate determinations of Ic.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (2) , 1-13
Possible Overestimation of I c Value of REBCO Tapes Due to the Narrow Bridge Fabricated by Laser Etching During Transport Measurements
Etching a narrow bridge on REBa2Cu3O7-x (REBCO, RE = Rare Earth) tape is a widely applied procedure during transport measurements of critical current (Ic), aiming to mitigate significant Lorentz forces. However, the microbridge can influence the measurement accuracy, and understanding this influence is crucial because it can bias the extrapolation of Ic to the full tape width. In this article, we reveal that the microbridge could result in an overestimation when extrapolating the full-width Ic values from microbridge ones. We identified two primary sources of this overestimation by systematically comparing the directly measured full-width Ic values with those extrapolated from narrow bridges under varying temperatures, applied magnetic fields, and field orientations. The first source arises from inaccuracies in the assumed cross-sectional geometry and area of the narrow bridge. Specifically, assuming a rectangular cross-section when the actual geometry is trapezoidal leads to significant overestimations. The second factor is the nonuniform pinning effect across the thickness of the REBCO layer. Although this effect is negligible at low magnetic fields and higher temperatures, it becomes significant at lower temperatures, high magnetic fields, and when the field is nearly parallel to the tape surface. Based on these findings, we propose an improved procedure for transport measurements using narrow bridges to achieve more accurate determinations of Ic.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Development of a Critical Current Measurement Platform for REBCO Tapes with Micro-Bridges Based on High-Frequency Pulse Current Injection
The critical current (Ic) of high-temperature superconducting (HTS) tapes is typically measured under steady-state magnetic fields using DC power supply. However, such fields are generally limited below 35 T, and generating higher steady-state magnetic fields requires considerable time and resources. In contrast, pulsed-field magnets enable shorter testing time and can exceed 50 T. Thus, we developed a high-frequency pulsed current injection platform for measuring Ic of HTS tapes under pulsed magnetic fields. Additionally, etched micro-bridges were employed to proportionally reduce the applied current and mitigate thermal effects that could degrade measurement accuracy. Taking the 50 T, 100-ms flat-top pulsed magnetic fields at the Wuhan National High Magnetic Field Center (WHMFC) as a potential application scenario, the proposed platform integrates a 20 kHz / 6.5-digit multimeter and a mixed-signal oscilloscope for synchronized acquisition. We investigated the effects of injection frequencies (2 kHz to 100 Hz), magnetic fields (0 T to 2 T), and temperatures (65 K to 83 K) on platform performance. The proposed platform was further validated against the conventional DC measurement method at 77 K, self-field.
- 5 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Development of a Critical Current Measurement Platform for REBCO Tapes with Micro-Bridges Based on High-Frequency Pulse Current Injection
The critical current (Ic) of high-temperature superconducting (HTS) tapes is typically measured under steady-state magnetic fields using DC power supply. However, such fields are generally limited below 35 T, and generating higher steady-state magnetic fields requires considerable time and resources. In contrast, pulsed-field magnets enable shorter testing time and can exceed 50 T. Thus, we developed a high-frequency pulsed current injection platform for measuring Ic of HTS tapes under pulsed magnetic fields. Additionally, etched micro-bridges were employed to proportionally reduce the applied current and mitigate thermal effects that could degrade measurement accuracy. Taking the 50 T, 100-ms flat-top pulsed magnetic fields at the Wuhan National High Magnetic Field Center (WHMFC) as a potential application scenario, the proposed platform integrates a 20 kHz / 6.5-digit multimeter and a mixed-signal oscilloscope for synchronized acquisition. We investigated the effects of injection frequencies (2 kHz to 100 Hz), magnetic fields (0 T to 2 T), and temperatures (65 K to 83 K) on platform performance. The proposed platform was further validated against the conventional DC measurement method at 77 K, self-field.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Experimental and Numerical Analysis of Critical Current Measurement of REBCO Tapes Using Pulsed and Direct Currents
The critical properties of REBa1Cu3O7-x (REBCO, RE = Rare Earth) tapes bring essential information about the construction of high field superconducting magnets. Typically, the magnetic field dependence of the critical current (Ic) in REBCO tapes is measured under steady-state magnetic fields using direct current measurements (DCMs). However, this method becomes time-consuming and generates significant heating. Pulsed current measurements (PCMs) can reduce current duty cycles and shorten the measuring time, but the accompanying high dI/dt may introduce bias in the measurement accuracy. In this study, both direct current and pulsed current were applied on the same samples at temperatures ranging from 20 K to 77 K and magnetic fields up to 18 T (steady-state). A two-dimensional (2-D) finite-element model based on the H-formulation was developed to analyze the current responses in REBCO tapes. The loss and temperature rise were also calculated. The results show that the critical currents measured by PCM and DCM exhibit consistent temperature and magnetic-field dependence. With the Ic extracted until the voltage is stabilized (during the period of dI/dt≈0), the PCM agrees with DCM generally within 10%. The simulation demonstrates that PCM is helpful in reducing the time-averaged loss.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Experimental and Numerical Analysis of Critical Current Measurement of REBCO Tapes Using Pulsed and Direct Currents
The critical properties of REBa1Cu3O7-x (REBCO, RE = Rare Earth) tapes bring essential information about the construction of high field superconducting magnets. Typically, the magnetic field dependence of the critical current (Ic) in REBCO tapes is measured under steady-state magnetic fields using direct current measurements (DCMs). However, this method becomes time-consuming and generates significant heating. Pulsed current measurements (PCMs) can reduce current duty cycles and shorten the measuring time, but the accompanying high dI/dt may introduce bias in the measurement accuracy. In this study, both direct current and pulsed current were applied on the same samples at temperatures ranging from 20 K to 77 K and magnetic fields up to 18 T (steady-state). A two-dimensional (2-D) finite-element model based on the H-formulation was developed to analyze the current responses in REBCO tapes. The loss and temperature rise were also calculated. The results show that the critical currents measured by PCM and DCM exhibit consistent temperature and magnetic-field dependence. With the Ic extracted until the voltage is stabilized (during the period of dI/dt≈0), the PCM agrees with DCM generally within 10%. The simulation demonstrates that PCM is helpful in reducing the time-averaged loss.