Model-based cardiac field artefact correction for OP-MEG
Open Access
- 3 September 2026
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Abstract
Each heartbeat creates an electro-magnetic field that propagates throughout the body and is superimposed on measured brain activity in electroencephalography (EEG) and magnetoencephalography (MEG) recordings. Being several orders of magnitude larger than a typical evoked response in the brain, the Cardiac Field Artefact (CFA) is especially problematic in studies where cortical activity time locked to the cardiac cycle is of interest, such as in interoception research. In this work, we develop a model-based CFA correction method, which exploits the fact that the magnetic field propagates relatively evenly through the mostly diamagnetic tissue of the human body, and that in studies using wearable optically pumped magnetometers (OP-MEG), participants are free to rotate their head. Free head rotation decouples the heart’s magnetic field from that of the brain, allowing for the creation of a cardiac dipole moment (CDM) estimate, that is, an estimate of the electrical current flow in the heart, which is minimally confounded by concurrent neuronal activity in the brain. We show in simulations that, given information about the relative position and orientation of head and chest, this CDM estimate can be used to predict and correct the sensor-level CFA by dynamically accounting for the spatial relationship between heart, brain, and sensors. We further provide an empirical proof-of-principle demonstration of the pipeline in a single participant using recordings with intermittent head movement, tracked by optical motion capture, as well as an established auditory response paradigm with well-characterized response pattern.Keywords
Funding Information
- Wellcome Trust (226793/Z/22/Z)
- Medical Research Council (MR/X012409/1)
- Wellcome Trust (226778/Z/22/Z)
This publication has 59 references indexed in Scilit:
- Interpretability of deep neural networks: A review of methods, classification and hardwareNeurocomputing, 2024
- Perceived time expands and contracts within each heartbeatCurrent Biology, 2023
- Towards a comprehensive assessment of interoception in a multi-dimensional frameworkBiological Psychology, 2022
- Systematic review and meta-analysis of the relationship between the heartbeat-evoked potential and interoceptionNeuroscience & Biobehavioral Reviews, 2021
- Removing Cardiac Artefacts in Magnetoencephalography with Resampled Moving Average SubtractionBrain Topography, 2016
- Rhythm makes the world go round: An MEG-TMS study on the role of right TPJ theta oscillations in embodied perspective takingCortex, 2016
- Semi-automatic identification of independent components representing EEG artifactClinical Neurophysiology, 2009
- The functional anatomy of the MMN: A DCM study of the roving paradigmNeuroImage, 2008
- Improving MEG source localizations: An automated method for complete artifact removal based on independent component analysisNeuroImage, 2008
- Signal-space projection method for separating MEG or EEG into componentsMedical & Biological Engineering & Computing, 1997