George C. O'NEill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
George C. O'NEill has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Gareth Robert Barnes
Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, WC1N 3AR, London, UK
10 shared publications Tim M. Tierney
Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom
8 shared publicationsGareth R. Barnes
Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK
6 shared publications- Matthew J. Brookes
Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom
6 shared publications - Nicholas A. Alexander
Functional Imaging Laboratory (FIL), Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology University College London London UK
6 shared publications Stephanie Mellor
Department of Imaging Neuroscience, UCL Queen Square Institute of Neurology, University College London, London, UK
6 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Model-based cardiac field artefact correction for OP-MEG
Each heartbeat creates an electro-magnetic field that propagates throughout the body and is superimposed on measured brain activity in electroencephalography (EEG) and magnetoencephalography (MEG) recordings. Being several orders of magnitude larger than a typical evoked response in the brain, the Cardiac Field Artefact (CFA) is especially problematic in studies where cortical activity time locked to the cardiac cycle is of interest, such as in interoception research. In this work, we develop a model-based CFA correction method, which exploits the fact that the magnetic field propagates relatively evenly through the mostly diamagnetic tissue of the human body, and that in studies using wearable optically pumped magnetometers (OP-MEG), participants are free to rotate their head. Free head rotation decouples the heart’s magnetic field from that of the brain, allowing for the creation of a cardiac dipole moment (CDM) estimate, that is, an estimate of the electrical current flow in the heart, which is minimally confounded by concurrent neuronal activity in the brain. We show in simulations that, given information about the relative position and orientation of head and chest, this CDM estimate can be used to predict and correct the sensor-level CFA by dynamically accounting for the spatial relationship between heart, brain, and sensors. We further provide an empirical proof-of-principle demonstration of the pipeline in a single participant using recordings with intermittent head movement, tracked by optical motion capture, as well as an established auditory response paradigm with well-characterized response pattern.
- 3 September 2026
- Published by MIT Press in Imaging Neuroscience
- Vol. 4
Open AccessModel-based cardiac field artefact correction for OP-MEG
Each heartbeat creates an electro-magnetic field that propagates throughout the body and is superimposed on measured brain activity in electroencephalography (EEG) and magnetoencephalography (MEG) recordings. Being several orders of magnitude larger than a typical evoked response in the brain, the Cardiac Field Artefact (CFA) is especially problematic in studies where cortical activity time locked to the cardiac cycle is of interest, such as in interoception research. In this work, we develop a model-based CFA correction method, which exploits the fact that the magnetic field propagates relatively evenly through the mostly diamagnetic tissue of the human body, and that in studies using wearable optically pumped magnetometers (OP-MEG), participants are free to rotate their head. Free head rotation decouples the heart’s magnetic field from that of the brain, allowing for the creation of a cardiac dipole moment (CDM) estimate, that is, an estimate of the electrical current flow in the heart, which is minimally confounded by concurrent neuronal activity in the brain. We show in simulations that, given information about the relative position and orientation of head and chest, this CDM estimate can be used to predict and correct the sensor-level CFA by dynamically accounting for the spatial relationship between heart, brain, and sensors. We further provide an empirical proof-of-principle demonstration of the pipeline in a single participant using recordings with intermittent head movement, tracked by optical motion capture, as well as an established auditory response paradigm with well-characterized response pattern.
- Open Access
- 19 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 26258
Volume conductor models for magnetospinography
The recent development of small, wearable, magnetic field sensors allow for the investigation of biomagnetic fields with a flexibility previously unavailable. We carry out forward computations to describe how current flow in the spinal cord and thorax gives rise to measurable magnetic fields outside the torso. We compare various open-access volume conductor models, in order to select the most parsimonious and accurate descriptor of the magnetic fields due to source current in the spinal cord. We find that fields produced due to current flow along the superior–inferior axis of the cord are relatively insensitive to the choice of volume conductor model. However, fields produced by current flow in predominantly left–right or anterior–posterior direction are significantly attenuated by the presence of bone in the forward model. Furthermore, volume conductors with bone demonstrate larger differences in field topographies for nearby sources compared to bone-free models. These findings suggest that precise modelling of spinal cord location and surrounding vertebrae will be important a-priori knowledge going forward.
- 19 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 26258
Open AccessVolume conductor models for magnetospinography
The recent development of small, wearable, magnetic field sensors allow for the investigation of biomagnetic fields with a flexibility previously unavailable. We carry out forward computations to describe how current flow in the spinal cord and thorax gives rise to measurable magnetic fields outside the torso. We compare various open-access volume conductor models, in order to select the most parsimonious and accurate descriptor of the magnetic fields due to source current in the spinal cord. We find that fields produced due to current flow along the superior–inferior axis of the cord are relatively insensitive to the choice of volume conductor model. However, fields produced by current flow in predominantly left–right or anterior–posterior direction are significantly attenuated by the presence of bone in the forward model. Furthermore, volume conductors with bone demonstrate larger differences in field topographies for nearby sources compared to bone-free models. These findings suggest that precise modelling of spinal cord location and surrounding vertebrae will be important a-priori knowledge going forward.
- Open Access
Using Wearable MEG to Study the Neural Control of Human Stepping
A central challenge in movement neuroscience is developing methods for non-invasive spatiotemporal imaging of brain activity during natural, whole-body movement. We test the utility of a new brain imaging modality, optically pumped magnetoencephalography (OP-MEG), as an instrument to study the spatiotemporal dynamics of human walking. Specifically, we ask whether known physiological signals can be recovered during discrete steps involving large-scale, whole-body translation. Our findings show that by using OP-MEG, we can image the brain during large-scale, natural movements. We provide proof-of-principle evidence for movement-related changes in beta band activity during stepping vs. standing, which are source-localized to the sensorimotor cortex. This work supports the significant potential of the OP-MEG modality for addressing fundamental questions in human gait research relevant to both the physiological and pathological mechanisms of walking.
Open AccessUsing Wearable MEG to Study the Neural Control of Human Stepping
A central challenge in movement neuroscience is developing methods for non-invasive spatiotemporal imaging of brain activity during natural, whole-body movement. We test the utility of a new brain imaging modality, optically pumped magnetoencephalography (OP-MEG), as an instrument to study the spatiotemporal dynamics of human walking. Specifically, we ask whether known physiological signals can be recovered during discrete steps involving large-scale, whole-body translation. Our findings show that by using OP-MEG, we can image the brain during large-scale, natural movements. We provide proof-of-principle evidence for movement-related changes in beta band activity during stepping vs. standing, which are source-localized to the sensorimotor cortex. This work supports the significant potential of the OP-MEG modality for addressing fundamental questions in human gait research relevant to both the physiological and pathological mechanisms of walking.
- Top Cited PapersOpen Access
- 27 June 2025
- Published by The Open Journal in Journal of Open Source Software
- Vol. 10 (110) , 8103
SPM 25: open source neuroimaging analysis software
Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.
- 27 June 2025
- Published by The Open Journal in Journal of Open Source Software
- Vol. 10 (110) , 8103
Top Cited PapersOpen AccessSPM 25: open source neuroimaging analysis software
Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.
- Open Access
- 13 March 2025
- Published by Wiley in European Journal of Neuroscience
- Vol. 61 (5) , e70060
Anatomically Veridical On‐Scalp Sensor Topographies
When working with sensor‐level data recorded using on‐scalp neuroimaging methods such as electroencephalography (EEG), it is common practice to use two‐dimensional (2D) representations of sensor positions to aid interpretation. Positioning of sensors relative to anatomy, as in the classic 10–20 system of EEG electrode placement, enables the use of 2D topographies that are familiar to many researchers and clinicians. However, when using another increasingly popular on‐scalp neuroimaging method, optically pumped magnetometer–based magnetoencephalography (OP‐MEG), bespoke sensor arrays are much more common, and these are not prepared according to any standard principle. Consequently, polar projection is often used to produce individual sensor topographies that are not directly related to anatomy and cannot be averaged across people simply. Given the current proliferation of OP‐MEG facilities globally, this issue will become an increasing hindrance when visualising OP‐MEG data, particularly for group studies. To address this problem, we adapted and extended the 10–20 system to build a flexible, anatomical projection method applied to digitised head shape, fiducials and sensor positions. We demonstrate that the method maintains spatially veridical representations across individuals improving on standard polar projections at varying OPM sensor array densities. By applying our projection method, the benefits of anatomically veridical 2D topographies can now be enjoyed when visualising data, such as those from OP‐MEG, regardless of variation in sensor placement as in sparse or focal arrays.
- 13 March 2025
- Published by Wiley in European Journal of Neuroscience
- Vol. 61 (5) , e70060
Open AccessAnatomically Veridical On‐Scalp Sensor Topographies
When working with sensor‐level data recorded using on‐scalp neuroimaging methods such as electroencephalography (EEG), it is common practice to use two‐dimensional (2D) representations of sensor positions to aid interpretation. Positioning of sensors relative to anatomy, as in the classic 10–20 system of EEG electrode placement, enables the use of 2D topographies that are familiar to many researchers and clinicians. However, when using another increasingly popular on‐scalp neuroimaging method, optically pumped magnetometer–based magnetoencephalography (OP‐MEG), bespoke sensor arrays are much more common, and these are not prepared according to any standard principle. Consequently, polar projection is often used to produce individual sensor topographies that are not directly related to anatomy and cannot be averaged across people simply. Given the current proliferation of OP‐MEG facilities globally, this issue will become an increasing hindrance when visualising OP‐MEG data, particularly for group studies. To address this problem, we adapted and extended the 10–20 system to build a flexible, anatomical projection method applied to digitised head shape, fiducials and sensor positions. We demonstrate that the method maintains spatially veridical representations across individuals improving on standard polar projections at varying OPM sensor array densities. By applying our projection method, the benefits of anatomically veridical 2D topographies can now be enjoyed when visualising data, such as those from OP‐MEG, regardless of variation in sensor placement as in sparse or focal arrays.
- Open Access
- 3 March 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Combining video telemetry and wearable MEG for naturalistic imaging
Neuroimaging studies have typically relied on rigorously controlled experimental paradigms to probe cognition, in which movement is restricted, primitive, an afterthought or merely used to indicate a subject’s choice. Whilst powerful, these paradigms do not often resemble how we behave in everyday life, so a new generation of ecologically valid experiments are being developed. Magnetoencephalography (MEG) measures neural activity by sensing extracranial magnetic fields. It has recently been transformed from a large, static imaging modality to a wearable method where participants can move freely. This makes wearable MEG systems a prime candidate for naturalistic experiments going forward. However, these experiments will also require novel methods to capture and integrate information about behaviour executed during neuroimaging, and it is not yet clear how this could be achieved. Here, we use video recordings of multi-limb dance moves, processed with open-source machine learning methods, to automatically identify time windows of interest in concurrent, wearable MEG data. In a first step, we compare a traditional, block-designed analysis of limb movements, where the times of interest are based on stimulus presentation, to an analysis pipeline based on hidden Markov model states derived from the video telemetry. Next, we show that it is possible to identify discrete modes of neuronal activity related to specific limbs and body posture by processing the participants’ choreographed movement in a dancing paradigm. This demonstrates the potential of combining video telemetry with mobile magnetoencephalography and other legacy imaging methods for future studies of complex and naturalistic behaviours.
- 3 March 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessCombining video telemetry and wearable MEG for naturalistic imaging
Neuroimaging studies have typically relied on rigorously controlled experimental paradigms to probe cognition, in which movement is restricted, primitive, an afterthought or merely used to indicate a subject’s choice. Whilst powerful, these paradigms do not often resemble how we behave in everyday life, so a new generation of ecologically valid experiments are being developed. Magnetoencephalography (MEG) measures neural activity by sensing extracranial magnetic fields. It has recently been transformed from a large, static imaging modality to a wearable method where participants can move freely. This makes wearable MEG systems a prime candidate for naturalistic experiments going forward. However, these experiments will also require novel methods to capture and integrate information about behaviour executed during neuroimaging, and it is not yet clear how this could be achieved. Here, we use video recordings of multi-limb dance moves, processed with open-source machine learning methods, to automatically identify time windows of interest in concurrent, wearable MEG data. In a first step, we compare a traditional, block-designed analysis of limb movements, where the times of interest are based on stimulus presentation, to an analysis pipeline based on hidden Markov model states derived from the video telemetry. Next, we show that it is possible to identify discrete modes of neuronal activity related to specific limbs and body posture by processing the participants’ choreographed movement in a dancing paradigm. This demonstrates the potential of combining video telemetry with mobile magnetoencephalography and other legacy imaging methods for future studies of complex and naturalistic behaviours.
- Open Access
Volume conductor models for magnetospinography
The recent development of small, wearable, magnetic field sensors allow for the investigation of biomagnetic fields with a flexibility previously unavailable. We carry out forward computations to describe how current flow in the spinal cord and thorax gives rise to measurable magnetic fields outside the torso. We compare various open-access volume conductor models, in order to select the most parsimonious and accurate descriptor of the magnetic fields due to source current in the spinal cord. We find that fields produced due to current flow along the superior-inferior axis of the cord are relatively insensitive to the choice of volume conductor model. However, fields produced by current flow in predominantly left-right or anterior-posterior direction are significantly attenuated by the presence of bone in the forward model. Furthermore, volume conductors with bone demonstrate larger differences in field topographies for nearby sources compared to bone-free models. These findings suggest that precise modelling of spinal cord location and surrounding vertebrae will be important a-priori knowledge going forward.
Open AccessVolume conductor models for magnetospinography
The recent development of small, wearable, magnetic field sensors allow for the investigation of biomagnetic fields with a flexibility previously unavailable. We carry out forward computations to describe how current flow in the spinal cord and thorax gives rise to measurable magnetic fields outside the torso. We compare various open-access volume conductor models, in order to select the most parsimonious and accurate descriptor of the magnetic fields due to source current in the spinal cord. We find that fields produced due to current flow along the superior-inferior axis of the cord are relatively insensitive to the choice of volume conductor model. However, fields produced by current flow in predominantly left-right or anterior-posterior direction are significantly attenuated by the presence of bone in the forward model. Furthermore, volume conductors with bone demonstrate larger differences in field topographies for nearby sources compared to bone-free models. These findings suggest that precise modelling of spinal cord location and surrounding vertebrae will be important a-priori knowledge going forward.
- Open Access
Is high-frequency activity evidence of an anterior temporal lobe network or micro-saccades?
There is renewed interest in electrical activity that extends beyond the typical electrophysiological 100 Hz bandwidth. This activity, often in the anterior temporal lobe, has been attributed to processes ranging from memory consolidation to epileptiform activity. Here, using an open-access resting state magnetoencephalography (MEG) dataset (n = 89), and a second task-based MEG dataset, we could reliably localise high-frequency power to the temporal lobes across multiple bands up to 300–400 Hz. A functional connectivity analysis of this activity revealed a robust resting state bilateral network between the temporal lobes. However, we also found robust coherence in the 100–200 and 200–300 Hz bands between source reconstructed MEG data and the electrooculography (EOG) localised to within the temporal poles. Additional denoising schemes applied to the data could reduce power localisation to the temporal poles but the topography of the functional network did not drastically alter. Whilst it is clear that this network is biological and robust to established denoising methods, we cannot definitively rule yet on whether this is of neural or myogenic origin.
Open AccessIs high-frequency activity evidence of an anterior temporal lobe network or micro-saccades?
There is renewed interest in electrical activity that extends beyond the typical electrophysiological 100 Hz bandwidth. This activity, often in the anterior temporal lobe, has been attributed to processes ranging from memory consolidation to epileptiform activity. Here, using an open-access resting state magnetoencephalography (MEG) dataset (n = 89), and a second task-based MEG dataset, we could reliably localise high-frequency power to the temporal lobes across multiple bands up to 300–400 Hz. A functional connectivity analysis of this activity revealed a robust resting state bilateral network between the temporal lobes. However, we also found robust coherence in the 100–200 and 200–300 Hz bands between source reconstructed MEG data and the electrooculography (EOG) localised to within the temporal poles. Additional denoising schemes applied to the data could reduce power localisation to the temporal poles but the topography of the functional network did not drastically alter. Whilst it is clear that this network is biological and robust to established denoising methods, we cannot definitively rule yet on whether this is of neural or myogenic origin.
- Open Access
Improved non-invasive detection of ictal and interictal epileptiform activity using Optically Pumped Magnetometers
Magneto- and Electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and consequently the sensitivity to, and localisation accuracy of, epileptiform activity. In addition, recording during seizures becomes feasible with these wearable sensors. We aimed to demonstrate these advantages of OPMs in a clinical population. Three adults with known weak sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system. Performance of the two systems was compared in terms of IED-rate and SNR. In one patient the OPMs detected IEDs that were not found with the SQUID-system. In one patient the spike yield was higher for the OPM data (9.00 versus 6.76), with negligible difference in SNR compared to the SQUID data (3.85 versus 3.93; U = -2.86, d = -0.14). This was also the case for a patient with a spike yield that was comparable to that for the SQUID data (after accounting for unilateral coverage with the OPMs; SNR 4.47 versus 4.57; U = -3.81, d = -0.14). For one patient the spike yield (11.03 versus 24.50) and SNR (4.39 versus 4.05; U = 9.53, d = -0.36) were both lower for the OPMs. In two patients no IEDs were found with either system. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. Overall, OPM data were very much comparable to those obtained with a cryogenic system: OPMs outperformed SQUIDs for two of the four patients with IEDs, with either a higher spike yield, or an ability to detect IEDs that were not observable in the SQUID data. For three patients the SNRs of IEDs were (slightly) lower in the OPM data than in the SQUID data, but with negligible effect sizes for two of these patients. The relatively cheap technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure.
Open AccessImproved non-invasive detection of ictal and interictal epileptiform activity using Optically Pumped Magnetometers
Magneto- and Electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and consequently the sensitivity to, and localisation accuracy of, epileptiform activity. In addition, recording during seizures becomes feasible with these wearable sensors. We aimed to demonstrate these advantages of OPMs in a clinical population. Three adults with known weak sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system. Performance of the two systems was compared in terms of IED-rate and SNR. In one patient the OPMs detected IEDs that were not found with the SQUID-system. In one patient the spike yield was higher for the OPM data (9.00 versus 6.76), with negligible difference in SNR compared to the SQUID data (3.85 versus 3.93; U = -2.86, d = -0.14). This was also the case for a patient with a spike yield that was comparable to that for the SQUID data (after accounting for unilateral coverage with the OPMs; SNR 4.47 versus 4.57; U = -3.81, d = -0.14). For one patient the spike yield (11.03 versus 24.50) and SNR (4.39 versus 4.05; U = 9.53, d = -0.36) were both lower for the OPMs. In two patients no IEDs were found with either system. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. Overall, OPM data were very much comparable to those obtained with a cryogenic system: OPMs outperformed SQUIDs for two of the four patients with IEDs, with either a higher spike yield, or an ability to detect IEDs that were not observable in the SQUID data. For three patients the SNRs of IEDs were (slightly) lower in the OPM data than in the SQUID data, but with negligible effect sizes for two of these patients. The relatively cheap technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure.
- Open Access
- 27 May 2022
- Published by Elsevier in NeuroImage
- Vol. 258, 119338
Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs
- 27 May 2022
- Published by Elsevier in NeuroImage
- Vol. 258, 119338
Open AccessSpherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs