NANicholas A. Alexander

Nicholas A. Alexander

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nicholas A. Alexander has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Neuro‐XR Primer: Blending Neuroscience and Extended Reality to Facilitate Cognitive Investigation

    by Clíona L. Murray, Nicholas A. Alexander, Paola Pinti, Samantha E. A. Gregory, Ulrike Senftleben

    Neuro‐XR refers to the amalgamation of neuroimaging and extended reality (XR) including augmented, mixed and virtual reality. Both sets of technology have developed rapidly and in isolation, and here, we show that they have great potential when combined. Mobile neuroimaging technology is becoming increasingly available, offering researchers greater flexibility. Similarly, XR devices are now affordable and lightweight and can be coupled with open‐source software for developing experiments. We are now at a time where neuroimaging and XR are paired to investigate new cognitive questions but also to replicate seminal research. Neuro‐XR provides cognitive neuroscience and XR‐based applications such as medicine, quantitative understanding (through behaviour and neural data) and analysis of real‐time interactions. In this primer, we introduce the term ‘Neuro‐XR’ and define the scope of the technique through a concept‐driven synthesis based on the literature and driven by the authors' expertise. More generally, we discuss the current research in the field and explore some potential future applications. Finally, we provide suggestions and guidance for practising Neuro‐XR based on our combined experience across these modalities.

  • Open Access

    Model-based cardiac field artefact correction for OP-MEG

    by Sascha P. Woelk, Nicholas A. Alexander, George C. O’NEill, Sarah N. Garfinkel, Gareth R. Barnes

    Each heartbeat creates an electro-magnetic field that propagates throughout the body and is superimposed on measured brain activity in electroencephalography (EEG) and magnetoencephalography (MEG) recordings. Being several orders of magnitude larger than a typical evoked response in the brain, the Cardiac Field Artefact (CFA) is especially problematic in studies where cortical activity time locked to the cardiac cycle is of interest, such as in interoception research. In this work, we develop a model-based CFA correction method, which exploits the fact that the magnetic field propagates relatively evenly through the mostly diamagnetic tissue of the human body, and that in studies using wearable optically pumped magnetometers (OP-MEG), participants are free to rotate their head. Free head rotation decouples the heart’s magnetic field from that of the brain, allowing for the creation of a cardiac dipole moment (CDM) estimate, that is, an estimate of the electrical current flow in the heart, which is minimally confounded by concurrent neuronal activity in the brain. We show in simulations that, given information about the relative position and orientation of head and chest, this CDM estimate can be used to predict and correct the sensor-level CFA by dynamically accounting for the spatial relationship between heart, brain, and sensors. We further provide an empirical proof-of-principle demonstration of the pipeline in a single participant using recordings with intermittent head movement, tracked by optical motion capture, as well as an established auditory response paradigm with well-characterized response pattern.


  • Open Access

    Modular Arrays for High Precision Wearable MEG

    by Nicholas A. Alexander, Alberto Mariola, Sahitya Puvvada, Yulia Bezsudnova, Tim M. Tierney, Gareth R. Barnes, Martina F. Callaghan

    Optically pumped magnetometers (OPMs) can be used for magnetoencephalography (MEG) with equivalent or improved signal to noise ratio, relative to cryogenic MEG, when sensors are placed close to the scalp. OPM-based MEG can also be used in mobile contexts if sensors are placed in lightweight, wearable arrays. Individually tailored, rigid helmets known as scannercasts are currently the only method capable of achieving on-scalp, mobile recordings with high precision. However, these scannercasts are expensive to produce, require structural imaging in advance of the experiment, and can incur lengthy downtime while sensors are transferred between scannercasts. Here, we introduce a solution to these challenges that retains the advantages of scannercasts. We provide detailed steps for constructing a modular, cap-based design, suitable for all head sizes. Using simulations, we compare the leadfield power of this array against an idealised array and a commercially available mobile solution. We then validate our proposed solution empirically, in five participants, and provide a complete data preparation and analysis pipeline. Our design expands the accessibility of OPM-based MEG, and increases participant throughput to levels comparable to other imaging modalities. Crucially, it removes the trade-off between signal quality, mobility and practicality, promoting the unique potential of OPM-based MEG as a tool for studying naturalistic behaviour, and clinical assessment with high precision.

  • Open Access

    Using Wearable MEG to Study the Neural Control of Human Stepping

    by Meaghan E. Spedden, George C. O’neill, Timothy O. West, Tim M. Tierney, Stephanie Mellor, Nicholas A. Alexander, Robert Seymour, Jesper Lundbye-Jensen, Jens Bo Nielsen, Simon F. Farmer, et al.

    A central challenge in movement neuroscience is developing methods for non-invasive spatiotemporal imaging of brain activity during natural, whole-body movement. We test the utility of a new brain imaging modality, optically pumped magnetoencephalography (OP-MEG), as an instrument to study the spatiotemporal dynamics of human walking. Specifically, we ask whether known physiological signals can be recovered during discrete steps involving large-scale, whole-body translation. Our findings show that by using OP-MEG, we can image the brain during large-scale, natural movements. We provide proof-of-principle evidence for movement-related changes in beta band activity during stepping vs. standing, which are source-localized to the sensorimotor cortex. This work supports the significant potential of the OP-MEG modality for addressing fundamental questions in human gait research relevant to both the physiological and pathological mechanisms of walking.


  • Top Cited Papers
    Open Access

    SPM 25: open source neuroimaging analysis software

    by Tim M. Tierney, Nicholas A. Alexander, John Ashburner, Nicole Labra Avila, Yaël Balbastre, Gareth Barnes, Yulia Bezsudnova, Mikael Brudfors, Korbinian Eckstein, Guillaume Flandin, et al.

    Statistical Parametric Mapping (SPM) is an integrated set of methods for testing hypotheses about the brain's structure and function, using data from imaging devices. These methods are implemented in an open source software package, SPM, which has been in continuous development for more than 30 years by an international community of developers. This paper reports the release of SPM 25.01, a major new version of the software that incorporates novel analysis methods, optimisations of existing methods, as well as improved practices for open science and software development.


  • Open Access

    BSD: A Bayesian Framework for Parametric Models of Neural Spectra

    by Johan Medrano, Nicholas A. Alexander, Robert A. Seymour, Peter Zeidman

    The analysis of neural power spectra plays a crucial role in understanding brain function and dysfunction. While recent efforts have led to the development of methods for decomposing spectral data, challenges remain in performing statistical analysis and group‐level comparisons. Here, we introduce Bayesian spectral decomposition (BSD), a Bayesian framework for analysing neural spectral power. BSD allows for the specification, inversion, comparison and analysis of parametric models of neural spectra, addressing limitations of existing methods. We first establish the face validity of BSD on simulated data and show how it outperforms an established method [fit oscillations and one‐over‐f (FOOOF)] for peak detection on artificial spectral data. We then demonstrate the efficacy of BSD on a group‐level study of electroencephalography (EEG) spectra in 204 healthy subjects from the LEMON dataset. Our results not only highlight the effectiveness of BSD in model selection and parameter estimation but also illustrate how BSD enables straightforward group‐level regression of the effect of continuous covariates such as age. By using Bayesian inference techniques, BSD provides a robust framework for studying neural spectral data and their relationship to brain function and dysfunction.


  • Open Access

    Wearable MEG data recorded during human stepping

    by Meaghan E. Spedden, George C. O’nEill, Timothy O. West, Tim M. Tierney, Stephanie Mellor, Nicholas A. Alexander, Robert Seymour, Jesper Lundbye-Jensen, Jens Bo Nielsen, Simon F. Farmer, et al.


  • Open Access

    Anatomically Veridical On‐Scalp Sensor Topographies

    by Nicholas A. Alexander, Johan Medrano, Robert A. Seymour, Stephanie Mellor, George C. O’nEill, Meaghan E. Spedden, Tim M. Tierney, Eleanor A. Maguire

    When working with sensor‐level data recorded using on‐scalp neuroimaging methods such as electroencephalography (EEG), it is common practice to use two‐dimensional (2D) representations of sensor positions to aid interpretation. Positioning of sensors relative to anatomy, as in the classic 10–20 system of EEG electrode placement, enables the use of 2D topographies that are familiar to many researchers and clinicians. However, when using another increasingly popular on‐scalp neuroimaging method, optically pumped magnetometer–based magnetoencephalography (OP‐MEG), bespoke sensor arrays are much more common, and these are not prepared according to any standard principle. Consequently, polar projection is often used to produce individual sensor topographies that are not directly related to anatomy and cannot be averaged across people simply. Given the current proliferation of OP‐MEG facilities globally, this issue will become an increasing hindrance when visualising OP‐MEG data, particularly for group studies. To address this problem, we adapted and extended the 10–20 system to build a flexible, anatomical projection method applied to digitised head shape, fiducials and sensor positions. We demonstrate that the method maintains spatially veridical representations across individuals improving on standard polar projections at varying OPM sensor array densities. By applying our projection method, the benefits of anatomically veridical 2D topographies can now be enjoyed when visualising data, such as those from OP‐MEG, regardless of variation in sensor placement as in sparse or focal arrays.


  • Open Access

    Oscillatory Neural Correlates of Police Firearms Decision-Making in Virtual Reality

    by Nicholas A. Alexander, Clíona L. Kelly, Hongfang Wang, Robert A. Nash, Shaun Beebe, Matthew J. Brookes, Klaus Kessler

    We investigated the neural signatures of expert decision-making in the context of police training in a virtual reality–based shoot/don’t shoot scenario. Police officers can use stopping force against a perpetrator, which may require using a firearm and each decision made by an officer to discharge their firearm or not has substantial implications. Therefore, it is important to understand the cognitive and underlying neurophysiological processes that lead to such a decision. We used virtual reality–based simulations to elicit ecologically valid behavior from authorized firearms officers (AFOs) in the UK and matched novices in a shoot/don't shoot task and recorded electroencephalography concurrently. We found that AFOs had consistently faster response times than novices, suggesting our task was sensitive to their expertise. To investigate differences in decision-making processes under varying levels of threat and expertise, we analyzed electrophysiological signals originating from the anterior cingulate cortex. In line with similar response inhibition tasks, we found greater increases in preresponse theta power when participants inhibited the response to shoot when under no threat as compared with shooting. Most importantly, we showed that when preparing against threat, theta power increase was greater for experts than novices, suggesting that differences in performance between experts and novices are due to their greater orientation toward threat. Additionally, shorter beta rebounds suggest that experts were “ready for action” sooner. More generally, we demonstrate that the investigation of expert decision-making should incorporate naturalistic stimuli and an appropriate control group to enhance validity.


  • Open Access

    Real-time, model-based magnetic field correction for moving, wearable MEG

    by Stephanie Mellor, Tim M. Tierney, Robert A. Seymour, Ryan C. Timms, George C. O'NEill, Nicholas Alexander, Meaghan E. Spedden, Heather Payne, Gareth R. Barnes