Sung-Min Sohn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sung-Min Sohn has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Zachary A. Colwell
School of Biomedical and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
4 shared publications - Sri Kirthi Kandala
School of Biomedical and Health Systems Engineering, Arizona State University, Tempe, AZ, USA
3 shared publications Chavalchart Herabut
School of Biological and Health Systems Engineering Arizona State University Tempe Arizona USA
2 shared publications- Seyedamin Hashemi
Affiliation School of Electrical, Computer and Energy Engineering, Arizona State University, Tempe, Arizona, United States of America
2 shared publications Sri Kirthi Kandala
School of Biological and Health Systems Engineering, Arizona State University, Tempe, USA
2 shared publicationsAnand Gopinath
Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, USA
1 shared publication
Latest Publications
- 18 June 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (8) , e70337
AeroCoil: Pneumatically Controlled Dual‐Tunable RF Coil for Proton ( 1 H) and Deuterium ( 2 H)
In specific MRI applications, RF coils must operate at multiple resonance frequencies to support multinuclear imaging and spectroscopy. Designing such coils that can either resonate at or switch between multiple frequencies presents considerable technical challenges. Traditional multituned coils typically suffer from strong electromagnetic (EM) coupling due to limited physical space and the interaction between multiple resonating structures. Frequency‐switchable coils offer an alternative by adjusting circuit capacitance or inductance to tune for different nuclei, typically relying on PIN diodes or similar electronic switches. However, these designs require frequency‐sensitive bias circuitry, dedicated drivers, and long DC control lines, all of which are prone to RF interference within the MRI environment. Furthermore, PIN diodes introduce inherent RF leakage and nonlinearities that can significantly degrade image quality. This study introduces a pneumatically actuated frequency‐switchable RF coil, termed AeroCoil, that enables resonance switching without electrical biasing. The AeroCoil design utilizes air pressure to mechanically adjust capacitance, enabling transitions between the 1 H and 2 H Larmor frequencies at 9.4 T. This pneumatic mechanism eliminates the need for local electrical components near the imaging volume, thereby reducing RF noise, eliminating EM interference, and simplifying the coil's circuit architecture. The AeroCoil's performance was benchmarked against single‐tuned coils, representing optimal performance at each frequency, and a PIN diode‐based switchable coil. Bench measurements evaluated return losses and quality factors, whereas MRI experiments assessed SNR and image artifacts. The AeroCoil retained 88.2%–91.9% of the SNR compared with a single‐tuned 1 H coil, whereas the PIN diode‐based 1 H coil achieved only 68.3%–75%. At the 2 H frequency, AeroCoil performance was further emphasized, retaining 71.7%–74.6% SNR, whereas the PIN diode‐based design dropped sharply to 27.1%–28.8%.
- 18 June 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (8) , e70337
AeroCoil: Pneumatically Controlled Dual‐Tunable RF Coil for Proton ( 1 H) and Deuterium ( 2 H)
In specific MRI applications, RF coils must operate at multiple resonance frequencies to support multinuclear imaging and spectroscopy. Designing such coils that can either resonate at or switch between multiple frequencies presents considerable technical challenges. Traditional multituned coils typically suffer from strong electromagnetic (EM) coupling due to limited physical space and the interaction between multiple resonating structures. Frequency‐switchable coils offer an alternative by adjusting circuit capacitance or inductance to tune for different nuclei, typically relying on PIN diodes or similar electronic switches. However, these designs require frequency‐sensitive bias circuitry, dedicated drivers, and long DC control lines, all of which are prone to RF interference within the MRI environment. Furthermore, PIN diodes introduce inherent RF leakage and nonlinearities that can significantly degrade image quality. This study introduces a pneumatically actuated frequency‐switchable RF coil, termed AeroCoil, that enables resonance switching without electrical biasing. The AeroCoil design utilizes air pressure to mechanically adjust capacitance, enabling transitions between the 1 H and 2 H Larmor frequencies at 9.4 T. This pneumatic mechanism eliminates the need for local electrical components near the imaging volume, thereby reducing RF noise, eliminating EM interference, and simplifying the coil's circuit architecture. The AeroCoil's performance was benchmarked against single‐tuned coils, representing optimal performance at each frequency, and a PIN diode‐based switchable coil. Bench measurements evaluated return losses and quality factors, whereas MRI experiments assessed SNR and image artifacts. The AeroCoil retained 88.2%–91.9% of the SNR compared with a single‐tuned 1 H coil, whereas the PIN diode‐based 1 H coil achieved only 68.3%–75%. At the 2 H frequency, AeroCoil performance was further emphasized, retaining 71.7%–74.6% SNR, whereas the PIN diode‐based design dropped sharply to 27.1%–28.8%.
- 27 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (1) , 780-786
Nonoverlapped Decoupling Technique With Flexible and Stretchable Dielectric-Loaded Coil Elements for Wearable Multichannel RF Coils
Radio frequency (RF) coils are RF front-end components in magnetic resonance imaging (MRI) system, which serve a significant role in determining image quality. This article introduces a novel decoupling technique using dielectric-loaded coils and evaluates their performance through bench tests, full-wave electromagnetic (EM) simulations, and MR imaging experiments at 9.4 T, thus at the Larmor frequency of 400 MHz. The proposed technique addresses the challenge of coupling between adjacent coil elements in an array and offers potential advantages for wearable multichannel RF coils. The results demonstrate comparable decoupling performance between a dielectric-loaded coil using a nonoverlapping method and a conventional coil with a 20% overlapped decoupling method. MR imaging experiments indicate improvements of 0.86%, 27.72%, and 8.94% in signal-to-noise ratio (SNR) at the near-surface region, center, and overall area encompassing both regions, respectively. Furthermore, the utilization of a dielectric-loaded coil resulted in an 89.8% enhancement in signal uniformity compared to the conventional overlapping technique. The proposed decoupling technique opens new opportunities for the development of flexible and stretchable coil structure toward wearable multichannel RF coils.
- 27 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 72 (1) , 780-786
Nonoverlapped Decoupling Technique With Flexible and Stretchable Dielectric-Loaded Coil Elements for Wearable Multichannel RF Coils
Radio frequency (RF) coils are RF front-end components in magnetic resonance imaging (MRI) system, which serve a significant role in determining image quality. This article introduces a novel decoupling technique using dielectric-loaded coils and evaluates their performance through bench tests, full-wave electromagnetic (EM) simulations, and MR imaging experiments at 9.4 T, thus at the Larmor frequency of 400 MHz. The proposed technique addresses the challenge of coupling between adjacent coil elements in an array and offers potential advantages for wearable multichannel RF coils. The results demonstrate comparable decoupling performance between a dielectric-loaded coil using a nonoverlapping method and a conventional coil with a 20% overlapped decoupling method. MR imaging experiments indicate improvements of 0.86%, 27.72%, and 8.94% in signal-to-noise ratio (SNR) at the near-surface region, center, and overall area encompassing both regions, respectively. Furthermore, the utilization of a dielectric-loaded coil resulted in an 89.8% enhancement in signal uniformity compared to the conventional overlapping technique. The proposed decoupling technique opens new opportunities for the development of flexible and stretchable coil structure toward wearable multichannel RF coils.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (4) , 432-439
Flexible, Stretchable, and MR-Invisible Dielectric Material for Magnetic Resonance Imaging
Flexible, stretchable, and MR-invisible dielectric materials were studied to increase the local magnetic field (B 1 ) and signal-to-noise ratio (SNR) in magnetic resonance imaging. An electromagnetic simulation was performed with different dielectric constants and physical structures to measure the effects on the magnetic field (H) distribution and the specific absorption rate (SAR). After flexible and stretchable dielectric pads composed of silicon carbide (SiC)- and barium titanate (BaTiO 3 )-based polymer mixtures were fabricated, MR imaging tests with two isotropic phantoms and an oxtail sample were performed in a preclinical 7 T scanner (BioSpec scanner, Bruker). The B 1 field intensities and SNR were compared with a reference image. Also, additional noise and image artifacts were evaluated. Simulation results show that wrapping an object with a dielectric material is the most effective method to increase the intensity and uniformity of the H field. The results of MR imaging consistently show a higher B 1 field intensity and SNR when utilizing dielectric materials. An improvement of 25.78% and 18.27% in SNR was observed when SiC- and BaTiO 3 -based dielectric pads were wrapped around an oxtail, respectively. In this work, the first stretchable dielectric materials with MR-invisibility were developed, and their performance was demonstrated with 7 T MR imaging.
- 16 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (4) , 432-439
Flexible, Stretchable, and MR-Invisible Dielectric Material for Magnetic Resonance Imaging
Flexible, stretchable, and MR-invisible dielectric materials were studied to increase the local magnetic field (B 1 ) and signal-to-noise ratio (SNR) in magnetic resonance imaging. An electromagnetic simulation was performed with different dielectric constants and physical structures to measure the effects on the magnetic field (H) distribution and the specific absorption rate (SAR). After flexible and stretchable dielectric pads composed of silicon carbide (SiC)- and barium titanate (BaTiO 3 )-based polymer mixtures were fabricated, MR imaging tests with two isotropic phantoms and an oxtail sample were performed in a preclinical 7 T scanner (BioSpec scanner, Bruker). The B 1 field intensities and SNR were compared with a reference image. Also, additional noise and image artifacts were evaluated. Simulation results show that wrapping an object with a dielectric material is the most effective method to increase the intensity and uniformity of the H field. The results of MR imaging consistently show a higher B 1 field intensity and SNR when utilizing dielectric materials. An improvement of 25.78% and 18.27% in SNR was observed when SiC- and BaTiO 3 -based dielectric pads were wrapped around an oxtail, respectively. In this work, the first stretchable dielectric materials with MR-invisibility were developed, and their performance was demonstrated with 7 T MR imaging.
- Open Access
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 303-316
Hawkeye: Hectometer-range Subcentimeter Localization for Large-scale mmWave Backscatter
- 18 June 2023
- Published by Association for Computing Machinery (ACM)
- p. 303-316
Open AccessHawkeye: Hectometer-range Subcentimeter Localization for Large-scale mmWave Backscatter
- 12 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 610-620
Standalone RF Self-Interference Cancellation System for In-Vivo Simultaneous Transmit and Receive (STAR) MRI
Demonstrated is a standalone RF self-interference canceller for simultaneous transmit and receive (STAR) magnetic resonance imaging (MRI) at 1.5T. Standalone STAR cancels the leakage signal directly coupled between transmit and receive RF coils. A cancellation signal, introduced by tapping the input of a transmit coil with a power divider, is manipulated with voltage-controlled attenuators and phase shifters to match the leakage signal in amplitude, 180° out of phase, to exhibit high isolation between the transmitter and receiver. The cancellation signal is initially generated by a voltage-controlled oscillator (VCO); therefore, it does not require any external RF or synchronization signals from the MRI console for calibration. The system employs a field programmable gate array (FPGA) with an on-board analog to digital converter (ADC) to calibrate the cancellation signal by tapping the receive signal, which contains the leakage signal. Once calibrated, the VCO is disabled and the transmit signal path switches to the MRI console for STAR MR imaging. To compensate for the changes of parameters in RF sequences after the automatic calibration and to further improve isolation, a wireless user board that uses an ESP32 microcontroller was built to communicate with the FPGA for final fine-tuning of the output state. The standalone STAR system achieved 74.2 dB of isolation with a 94 second calibration time. With such high isolation, in-vivo MR images were obtained with approximately 40 mW of RF peak power.
- 12 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 610-620
Standalone RF Self-Interference Cancellation System for In-Vivo Simultaneous Transmit and Receive (STAR) MRI
Demonstrated is a standalone RF self-interference canceller for simultaneous transmit and receive (STAR) magnetic resonance imaging (MRI) at 1.5T. Standalone STAR cancels the leakage signal directly coupled between transmit and receive RF coils. A cancellation signal, introduced by tapping the input of a transmit coil with a power divider, is manipulated with voltage-controlled attenuators and phase shifters to match the leakage signal in amplitude, 180° out of phase, to exhibit high isolation between the transmitter and receiver. The cancellation signal is initially generated by a voltage-controlled oscillator (VCO); therefore, it does not require any external RF or synchronization signals from the MRI console for calibration. The system employs a field programmable gate array (FPGA) with an on-board analog to digital converter (ADC) to calibrate the cancellation signal by tapping the receive signal, which contains the leakage signal. Once calibrated, the VCO is disabled and the transmit signal path switches to the MRI console for STAR MR imaging. To compensate for the changes of parameters in RF sequences after the automatic calibration and to further improve isolation, a wireless user board that uses an ESP32 microcontroller was built to communicate with the FPGA for final fine-tuning of the output state. The standalone STAR system achieved 74.2 dB of isolation with a 94 second calibration time. With such high isolation, in-vivo MR images were obtained with approximately 40 mW of RF peak power.
- Open Access
Hawkeye: Hectometer-range Subcentimeter Localization for Large-scale mmWave Backscatter
Accurate localization of a large number of objects over a wide area is one of the keys to the pervasive interaction with the Internet of Things. This paper presents Hawkeye, a new mmWave backscatter that, for the first time, offers over (i) hundred-scale simultaneous 3D localization at (ii) subcentimeter accuracy for over an (iii) hectometer distance. Hawkeye generally applies to indoors and outdoors as well as under mobility. Hawkeye tag's Van Atta Array design with retro-reflectivity in both elevation and azimuth planes offers 3D localization and effectively suppresses the multipath. Hawkeye localization algorithm is a lightweight signal processing compatible with the commodity FMCW radar. It uniquely leverages the interplay between the tag signal and clutter, and leverages the spetral leakage for fine-grained positioning. Prototype evaluations in corridor, lecture room, and soccer field reveal 6.7 mm median accuracy at 160 m range, and simultaneously localizes 100 tags in only 33.2 ms. Hawkeye is reliable under temperature change with significant oscillator frequency offset.
Open AccessHawkeye: Hectometer-range Subcentimeter Localization for Large-scale mmWave Backscatter
Accurate localization of a large number of objects over a wide area is one of the keys to the pervasive interaction with the Internet of Things. This paper presents Hawkeye, a new mmWave backscatter that, for the first time, offers over (i) hundred-scale simultaneous 3D localization at (ii) subcentimeter accuracy for over an (iii) hectometer distance. Hawkeye generally applies to indoors and outdoors as well as under mobility. Hawkeye tag's Van Atta Array design with retro-reflectivity in both elevation and azimuth planes offers 3D localization and effectively suppresses the multipath. Hawkeye localization algorithm is a lightweight signal processing compatible with the commodity FMCW radar. It uniquely leverages the interplay between the tag signal and clutter, and leverages the spetral leakage for fine-grained positioning. Prototype evaluations in corridor, lecture room, and soccer field reveal 6.7 mm median accuracy at 160 m range, and simultaneously localizes 100 tags in only 33.2 ms. Hawkeye is reliable under temperature change with significant oscillator frequency offset.
- Open Access
- 14 December 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Design of standalone wireless impedance matching (SWIM) system for RF coils in MRI
The radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise ratio (SNR) at the receive signal chain are directly dependent on the impedance matching condition presented by a loaded coil, tuned to the Larmor frequency. Sub-optimal impedance condition of receive coils significantly reduces coil sensitivity and image quality. In this study we propose a Standalone Wireless Impedance Matching (SWIM) system for RF coils to automatically compensate for the impedance mismatch caused by the loading effect at the target frequency. SWIM uses a built-in RF generator to produce a calibration signal, measure reflected power as feedback for loading change, and determine an optimal impedance. The matching network consists of a capacitor array with micro-electromechanical system (MEMS) RF switches to electronically cycle through different input impedance conditions. Along with automatic calibration, SWIM can also perform software detuning of RF receive coils. An Android mobile application was developed for real-time reflected power monitoring and controlling the SWIM system via Bluetooth. The SWIM system can automatically calibrate an RF coil in 3 s and the saline sample SNR was improved by 24% when compared to a loaded coil without retuning. Four different tomatoes were imaged to validate the performance of SWIM.
- 14 December 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Open AccessDesign of standalone wireless impedance matching (SWIM) system for RF coils in MRI
The radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise ratio (SNR) at the receive signal chain are directly dependent on the impedance matching condition presented by a loaded coil, tuned to the Larmor frequency. Sub-optimal impedance condition of receive coils significantly reduces coil sensitivity and image quality. In this study we propose a Standalone Wireless Impedance Matching (SWIM) system for RF coils to automatically compensate for the impedance mismatch caused by the loading effect at the target frequency. SWIM uses a built-in RF generator to produce a calibration signal, measure reflected power as feedback for loading change, and determine an optimal impedance. The matching network consists of a capacitor array with micro-electromechanical system (MEMS) RF switches to electronically cycle through different input impedance conditions. Along with automatic calibration, SWIM can also perform software detuning of RF receive coils. An Android mobile application was developed for real-time reflected power monitoring and controlling the SWIM system via Bluetooth. The SWIM system can automatically calibrate an RF coil in 3 s and the saline sample SNR was improved by 24% when compared to a loaded coil without retuning. Four different tomatoes were imaged to validate the performance of SWIM.
- 3 August 2022
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 15 (5) , 805-809
Miniaturized tunable extended eight-port hybrid coupler for 1.5 T MRI
This paper presents a miniaturized, tunable, high-power, eight-port hybrid coupler, based on a lumped element hybrid coupler topology. The 90° hybrid couplers are ubiquitous elements used for feeding RF coils in quadrature in magnetic resonance imaging (MRI) systems. Due to the low Larmor frequency (64 MHz) of 1.5 T MRI, distributed elements are too large for practical circuits to drive multi-port RF coils. Thus, miniaturization with MRI-compatible, non-magnetic, and high-power components is necessary. First, a miniaturized hybrid coupler is proposed for MRI systems with non-magnetic variable capacitors. Afterwards, the miniaturization methodology is applied to develop an eight-port coupler, capable of supporting both a transmit and a receive quadrature RF coil system. The high-power (up to 1 kilowatt) extended coupler measures 10 cm × 6 cm. Test results show that each port has a return loss of more than 16 dB, each input-isolated port is isolated by more than 24 dB, and each output has an insertion loss of less than 2.5 dB and output phases of 0.0°, 90.8°, 182.1°, and 278.7°.
- 3 August 2022
- Published by Cambridge University Press (CUP) in International Journal of Microwave and Wireless Technologies
- Vol. 15 (5) , 805-809
Miniaturized tunable extended eight-port hybrid coupler for 1.5 T MRI
This paper presents a miniaturized, tunable, high-power, eight-port hybrid coupler, based on a lumped element hybrid coupler topology. The 90° hybrid couplers are ubiquitous elements used for feeding RF coils in quadrature in magnetic resonance imaging (MRI) systems. Due to the low Larmor frequency (64 MHz) of 1.5 T MRI, distributed elements are too large for practical circuits to drive multi-port RF coils. Thus, miniaturization with MRI-compatible, non-magnetic, and high-power components is necessary. First, a miniaturized hybrid coupler is proposed for MRI systems with non-magnetic variable capacitors. Afterwards, the miniaturization methodology is applied to develop an eight-port coupler, capable of supporting both a transmit and a receive quadrature RF coil system. The high-power (up to 1 kilowatt) extended coupler measures 10 cm × 6 cm. Test results show that each port has a return loss of more than 16 dB, each input-isolated port is isolated by more than 24 dB, and each output has an insertion loss of less than 2.5 dB and output phases of 0.0°, 90.8°, 182.1°, and 278.7°.
- Open Access
- 2 August 2022
- Published by Springer Nature in Research Square
Design of Standalone Wireless Impedance Matching (SWIM) System for RF Coils in MRI
The radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise ratio (SNR) at the receive signal chain are directly dependent on the impedance matching condition presented by a loaded coil, tuned to the Larmor frequency. Sub-optimal impedance condition of receive coils significantly reduce coil sensitivity and image quality. In this study we propose a Standalone Wireless Impedance Matching (SWIM) system for RF coils to automatically compensate for the impedance mismatch caused by the loading effect at the target frequency. SWIM uses a built-in RF generator to produce a calibration signal, measure reflected power as feedback for loading change, and determine an optimal impedance. The matching network consists of a capacitor array with micro-electromechanical system (MEMS) RF switches to electronically cycle through different input impedance conditions. Along with automatic calibration, SWIM can also perform software detuning of RF receive coils. An Android mobile application was developed to monitor reflected power in real-time and control the SWIM system wirelessly via Bluetooth. The SWIM system can automatically calibrate the coil to a 33 dB return loss in 3 seconds and the SNR was improved by 24% (26.85 dB to 34.15 dB) when compared to a loaded coil without retuning.
- 2 August 2022
- Published by Springer Nature in Research Square
Open AccessDesign of Standalone Wireless Impedance Matching (SWIM) System for RF Coils in MRI
The radio frequency (RF) power transfer efficiency of transmit coils and the signal-to-noise ratio (SNR) at the receive signal chain are directly dependent on the impedance matching condition presented by a loaded coil, tuned to the Larmor frequency. Sub-optimal impedance condition of receive coils significantly reduce coil sensitivity and image quality. In this study we propose a Standalone Wireless Impedance Matching (SWIM) system for RF coils to automatically compensate for the impedance mismatch caused by the loading effect at the target frequency. SWIM uses a built-in RF generator to produce a calibration signal, measure reflected power as feedback for loading change, and determine an optimal impedance. The matching network consists of a capacitor array with micro-electromechanical system (MEMS) RF switches to electronically cycle through different input impedance conditions. Along with automatic calibration, SWIM can also perform software detuning of RF receive coils. An Android mobile application was developed to monitor reflected power in real-time and control the SWIM system wirelessly via Bluetooth. The SWIM system can automatically calibrate the coil to a 33 dB return loss in 3 seconds and the SNR was improved by 24% (26.85 dB to 34.15 dB) when compared to a loaded coil without retuning.
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 21 (10) , 2075-2079
Flexible Metamaterial Wrap for Improved Head Imaging at 3 T MRI With Low-Cost and Easy Fabrication Method
Magnetic resonance imaging requires spatial uniformity of the radiofrequency (RF) field inside the subject for maximum signal-to-noise ratio and image contrast. Bulky high permittivity dielectric pads (HPDPs) focus magnetic fields into the region of interest (ROI) and increase RF field uniformity when placed between the patient and RF coils in the MR scanner. Metamaterials could replace HPDPs and reduce system bulkiness, but those in the literature often require a complicated fabrication process and cannot conform to patient body shape. Proposed is a flexible metamaterial for brain imaging made with a scalable fabrication process using conductive paint and a plastic laminate substrate. The effects of single and double-sided placement of the metamaterial around a human head phantom were investigated in a 3 T scanner. When two metamaterial sheets were wrapped around a head phantom (double-sided placement), the total average signal in the resulting image increased by 10.14% compared to placing a single metamaterial sheet underneath the phantom (single-sided placement). The difference between the maximum and minimum signal intensity values decreased by 57% in six different ROIs with double-sided placement compared to single-sided placement.
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 21 (10) , 2075-2079
Flexible Metamaterial Wrap for Improved Head Imaging at 3 T MRI With Low-Cost and Easy Fabrication Method
Magnetic resonance imaging requires spatial uniformity of the radiofrequency (RF) field inside the subject for maximum signal-to-noise ratio and image contrast. Bulky high permittivity dielectric pads (HPDPs) focus magnetic fields into the region of interest (ROI) and increase RF field uniformity when placed between the patient and RF coils in the MR scanner. Metamaterials could replace HPDPs and reduce system bulkiness, but those in the literature often require a complicated fabrication process and cannot conform to patient body shape. Proposed is a flexible metamaterial for brain imaging made with a scalable fabrication process using conductive paint and a plastic laminate substrate. The effects of single and double-sided placement of the metamaterial around a human head phantom were investigated in a 3 T scanner. When two metamaterial sheets were wrapped around a head phantom (double-sided placement), the total average signal in the resulting image increased by 10.14% compared to placing a single metamaterial sheet underneath the phantom (single-sided placement). The difference between the maximum and minimum signal intensity values decreased by 57% in six different ROIs with double-sided placement compared to single-sided placement.