Direct His Bundle and Parahisian Cardiac Pacing
Authors:
- 26 April 2012
- journal article
- review article
- Published by Wiley in Annals of Noninvasive Electrocardiology
- Vol. 17 (2) , 70-78
Abstract
The success rate of direct His bundle pacing (DHBP) and paraHisian pacing has improved remarkably in the last 3–5 years with the advent of dedicated fixation systems that have reduced procedural duration, dislodgement rate, and fluoroscopy time. The methodology of DBHP remains still more complex than paraHisian pacing and is associated with high‐pacing thresholds. Thus, DHBP entails greater battery current drain and reduced device longevity. A shift toward paraHisian pacing (which is fusion pacing of myocardium and His bundle) has occurred because its implementation is easier and the electrical parameters are superior to those of DBHP. Currently, an additional safety lead is inserted at the RV apex or outflow tract to prevent asystole, especially in patients with pure DHBP. It is often possible to avoid a safety lead with paraHisian pacing because ventricular pacing is virtually assured on a long‐term basis via myocardial capture. DBHP and paraHisian pacing can be achieved in a substantial proportion of patients with varying grades of narrow QRS AV block or after AV junctional ablation and in some patients with the ECG manifestation of bundle branch block caused by an intraHisian lesion. Preliminary observations suggest that DHBP may be useful in some patients requiring cardiac resynchronization if it produces a narrow QRS complex because the site of an intraHisian lesion responsible for left bundle branch block is above the site of DHBP.Keywords
This publication has 32 references indexed in Scilit:
- Electrical and Mechanical Cardiac Resynchronisation by Novel Direct His-bundle Pacing in a Heart Failure PatientHeart, Lung and Circulation, 2011
- Future easy and physiological cardiac pacingWorld Journal of Cardiology, 2011
- Ventricular Resynchronization by Implementation of Direct His Bundle Pacing in a Patient with Congenital Complete AV Block and Newly Diagnosed CardiomyopathyJournal of Cardiovascular Electrophysiology, 2010
- Physiologic Resynchronization Therapy: A Case of His Bundle Pacing Reversing Physiologic Conduction in a Patient with CHF and LBBB During 2 Years of ObservationJournal of Cardiovascular Electrophysiology, 2010
- Safety and Performance of a System Specifically Designed for Selective Site PacingPacing and Clinical Electrophysiology, 2010
- Electrical resynchronization induced by direct His-bundle pacingHeart Rhythm, 2010
- Normalization of bundle branch block patterns by distal His bundle pacing. Clinical and experimental evidence of longitudinal dissociation in the pathologic his bundle.Circulation, 1978
- Longitudinal dissociation in the His bundle. Bundle branch block due to asynchronous conduction within the His bundle in man.Circulation, 1977
- Fine Structure of the His BundleCirculation, 1971
- Pervenous Pacing of the Specialized Conducting System in ManCirculation, 1970