A daylighting field study using human feedback and simulations to test and improve recently adopted annual daylight performance metrics
- 23 September 2016
- journal article
- research article
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 10 (5-6) , 471-483
Abstract
With the latest published annual climate-based daylighting metrics and performance criteria, annual daylighting simulation has become more important to the design professions, but interpretation and application of these data are still relatively novel. This paper documents an eight-year human factors daylighting field research project using students' qualitative assessments of daylight sufficiency and corresponding point-in-time and annual climate-based daylighting simulation in a variety of commercial spaces (n = 22) in order to provide insight to the building performance simulation community about application of these new annual daylighting metrics. The sensitivity analysis on horizontal illuminance thresholds consistently represents high correlation with students' subjective responses and annual simulation results at 250 lx, whereas point-in-time analyses produces a range of best-fitting thresholds from 200 to 300 lx for daylight sufficiency. Additionally, the study reveals that ASE 1000 lx 250 hours at 10% threshold warrants refinement, and perhaps temporal or space type sensitivity should be applied to these criteria.Keywords
This publication has 7 references indexed in Scilit:
- Revisiting the Daylit Area: Examining Daylighting Performance Using Subjective Human Evaluations and Simulated Compliance with the LEED Version 4 Daylight CreditLEUKOS, 2016
- Opinion: Climate-based daylighting metrics in LEEDv4 – A fragile progressLighting Research & Technology, 2015
- Visual Comfort, Discomfort Glare, and Occupant Fenestration Control: Developing a Research AgendaLEUKOS, 2014
- Predicting the Daylit Area—A Comparison of Students Assessments and Simulations at Eleven Schools of ArchitectureLEUKOS, 2014
- A validation of the Radiance three-phase simulation method for modelling annual daylight performance of optically complex fenestration systemsJournal of Building Performance Simulation, 2013
- The daylit area – Correlating architectural student assessments with current and emerging daylight availability metricsBuilding and Environment, 2012
- On the Effects of Non-Normality on the Distribution of the Sample Product-Moment Correlation CoefficientJournal of the Royal Statistical Society Series C: Applied Statistics, 1972