Amir Nezamdoost
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amir Nezamdoost has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kevin Van Den Wymelenberg
Institute for Health in the Built Environment, University of Oregon, Eugene, Oregon
3 shared publications Alen Mahic
1 shared publicationDamon Woods
University of Idaho, Integrated Design Lab, Boise, ID, United States
1 shared publication- Elizabeth Cooper
University College London
1 shared publication
Latest Publications
- 1 August 2018
- Published by Elsevier in Automation in Construction
- Vol. 92, 133-150
Assessing the energy and daylighting impacts of human behavior with window shades, a life-cycle comparison of manual and automated blinds
- 1 August 2018
- Published by Elsevier in Automation in Construction
- Vol. 92, 133-150
Assessing the energy and daylighting impacts of human behavior with window shades, a life-cycle comparison of manual and automated blinds
- 1 January 2018
- Published by Elsevier in Energy and Buildings
- Vol. 159, 319-331
Using a passive design toolset to evaluate low-cost cooling strategies for an industrial facility in a hot and dry climate
- 1 January 2018
- Published by Elsevier in Energy and Buildings
- Vol. 159, 319-331
Using a passive design toolset to evaluate low-cost cooling strategies for an industrial facility in a hot and dry climate
- 18 November 2016
- Published by Taylor & Francis in LEUKOS
- Vol. 13 (2) , 107-123
Revisiting the Daylit Area: Examining Daylighting Performance Using Subjective Human Evaluations and Simulated Compliance with the LEED Version 4 Daylight Credit
The IES Lighting Measurement 83-12 Approved Method: IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE) (LM-83) codifies annual climate–based daylighting metrics and performance criteria, yet interpretation and application of the metrics and criteria are not fully substantiated. This article reports “daylit area” drawings prepared in the field by architecture students and compares these drawings to corresponding point-in-time and annual daylighting simulations. The point-in-time simulations without blinds showed less discrepancy between student daylit area evaluations than did annual simulations with blinds operated per LM-83. The daylit area drawings and point-in-time simulations together suggest a horizontal illuminance of 100 lx differentiating between non-daylit and partially daylit areas and 250 lx differentiating between partially and fully daylit areas. For 18 annual simulations that employed the LM-83 protocol, half were characterized similar to the field assessments. The other half consistently underpredicted daylight ratings; students found the spaces to be fully or partially daylit when the annual simulation predicted the spaces to be non-daylit. This study suggests that the spatial daylight autonomy (sDA) and ASE criteria in LM-83 may warrant refinement.
- 18 November 2016
- Published by Taylor & Francis in LEUKOS
- Vol. 13 (2) , 107-123
Revisiting the Daylit Area: Examining Daylighting Performance Using Subjective Human Evaluations and Simulated Compliance with the LEED Version 4 Daylight Credit
The IES Lighting Measurement 83-12 Approved Method: IES Spatial Daylight Autonomy (sDA) and Annual Sunlight Exposure (ASE) (LM-83) codifies annual climate–based daylighting metrics and performance criteria, yet interpretation and application of the metrics and criteria are not fully substantiated. This article reports “daylit area” drawings prepared in the field by architecture students and compares these drawings to corresponding point-in-time and annual daylighting simulations. The point-in-time simulations without blinds showed less discrepancy between student daylit area evaluations than did annual simulations with blinds operated per LM-83. The daylit area drawings and point-in-time simulations together suggest a horizontal illuminance of 100 lx differentiating between non-daylit and partially daylit areas and 250 lx differentiating between partially and fully daylit areas. For 18 annual simulations that employed the LM-83 protocol, half were characterized similar to the field assessments. The other half consistently underpredicted daylight ratings; students found the spaces to be fully or partially daylit when the annual simulation predicted the spaces to be non-daylit. This study suggests that the spatial daylight autonomy (sDA) and ASE criteria in LM-83 may warrant refinement.
- 23 September 2016
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 10 (5-6) , 471-483
A daylighting field study using human feedback and simulations to test and improve recently adopted annual daylight performance metrics
With the latest published annual climate-based daylighting metrics and performance criteria, annual daylighting simulation has become more important to the design professions, but interpretation and application of these data are still relatively novel. This paper documents an eight-year human factors daylighting field research project using students' qualitative assessments of daylight sufficiency and corresponding point-in-time and annual climate-based daylighting simulation in a variety of commercial spaces (n = 22) in order to provide insight to the building performance simulation community about application of these new annual daylighting metrics. The sensitivity analysis on horizontal illuminance thresholds consistently represents high correlation with students' subjective responses and annual simulation results at 250 lx, whereas point-in-time analyses produces a range of best-fitting thresholds from 200 to 300 lx for daylight sufficiency. Additionally, the study reveals that ASE 1000 lx 250 hours at 10% threshold warrants refinement, and perhaps temporal or space type sensitivity should be applied to these criteria.
- 23 September 2016
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 10 (5-6) , 471-483
A daylighting field study using human feedback and simulations to test and improve recently adopted annual daylight performance metrics
With the latest published annual climate-based daylighting metrics and performance criteria, annual daylighting simulation has become more important to the design professions, but interpretation and application of these data are still relatively novel. This paper documents an eight-year human factors daylighting field research project using students' qualitative assessments of daylight sufficiency and corresponding point-in-time and annual climate-based daylighting simulation in a variety of commercial spaces (n = 22) in order to provide insight to the building performance simulation community about application of these new annual daylighting metrics. The sensitivity analysis on horizontal illuminance thresholds consistently represents high correlation with students' subjective responses and annual simulation results at 250 lx, whereas point-in-time analyses produces a range of best-fitting thresholds from 200 to 300 lx for daylight sufficiency. Additionally, the study reveals that ASE 1000 lx 250 hours at 10% threshold warrants refinement, and perhaps temporal or space type sensitivity should be applied to these criteria.