Output ratio in air for MLC shaped irregular fields
Authors:
- Timothy C. ZhuTZTimothy C. Zhu
- Bengt E. BjärngardBBBengt E. Bjärngard
- Ying XiaoYXYing Xiao
- Mike BiedaMBMike Bieda
- 20 August 2004
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (9) , 2480-2490
Abstract
For accurate monitor unit calculation, it is important to calculate the output ratio in air, Sc, for an irregular field shaped by MLC. We have developed an algorithm to calculate Sc based on an empirical model [Med. Phys. 28, 925-937 (2001)] by projecting each leaf position to the isocenter plane. Thus it does not require the exact knowledge of the head geometry. Comparisons were made for three different types of MLC: those with MLC replacing the inner collimator jaws; those with MLC replacing the outer collimator jaws; and those with MLC as a tertiary attachment. When the MLC leaf positions are substantially different from the secondary collimators (or the rectangular field encompassing the irregular field), one observes an up to 5% difference in the value of head-scatter correction factor, HCF, defined as the ratio of output ratio in air between the MLC shaped irregular field and that of the rectangular field encompassing the irregular field. No collimator exchange effect was observed for rectangular fields shaped by MLC (e.g., 5x30 and 30x5 cm2 diagonal) when the secondary collimators are fixed, unlike that for the rectangular fields shaped by the inner and outer collimator jaws, where it can be 1-2%. For the same MLC shaped irregular field, the value of Sc increases from the Elekta, to the Siemens, to the Varian accelerators, with an up to 4% difference. The calculation agrees with measurement to within 1.2% for points both on and off the central-axis. The fitting parameters used in the algorithm are derived from measurements for square field sizes on the central-axis.Keywords
This publication has 27 references indexed in Scilit:
- Modeling the output ratio in air for megavoltage photon beamsMedical Physics, 2001
- Two-effective-source method for the calculation of in-air output at various source-to-detector distances in wedged fieldsMedical Physics, 1999
- A generalized solution for the calculation of in‐air output factors in irregular fieldsMedical Physics, 1998
- Scattered photons from wedges in high-energy x-ray beamsMedical Physics, 1995
- The relation between wedge factors in air and waterMedical Physics, 1994
- Wedge factor constituents of high energy photon beams: field size and depth dependenceRadiotherapy and Oncology, 1994
- How is photon head scatter in a linear accelerator related to the concept of a virtual source?Physics in Medicine & Biology, 1993
- On the field-size dependence of relative output from a linear acceleratorMedical Physics, 1992
- Head-scatter factors and effective x-ray source positions in a 25-MV linear acceleratorMedical Physics, 1992
- Scattered photons produced by beam‐modifying filtersMedical Physics, 1986