Use of Low-Glucose Alerts and Their Impact on Continuous Glucose Monitoring Outcomes in Real-World Use of the MiniMed 780G System.
- 15 July 2026
- journal article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
Abstract
Hypoglycemia remains a major concern in insulin therapy and has limited intensive glycemic control. Although automated insulin delivery substantially reduces hypoglycemia risk, relatively high low-glucose alert (LA) thresholds (LGAT) remain commonly used. This study evaluated the impact of user-set LGAT on glycemic outcomes. This retrospective cohort study analyzed anonymized real-world data from 169,487 MiniMed 780G users with type 1 diabetes across Europe, the Middle East, and Africa (August 1, 2024-July 31, 2025). Use of LAs, user-set thresholds, and glycemic metrics was evaluated. Most users (96%) enabled LGAT, and 36% enabled predictive LGAT. Median, 25th and 75th percentiles of time below 54 and 70 mg/dL remained low and within recommended targets across all alert thresholds overall, in users aged ≤15 years, and overnight. Hypoglycemia targets were achieved by >82% and >90% of users with thresholds <60 and ≥60 mg/dL, respectively. In contrast, time in range (TIR) 70-180 mg/dL and hyperglycemia targets were more frequently achieved with LGAT <60 mg/dL, with 70% and 61% meeting these targets, respectively. Overall, 43% of users with LGAT 80 mg/dL. A LGAT below 60 mg/dL is generally recommended, as it is associated with increased TIR, reduced hyperglycemia, and low time in hypoglycemia. A threshold between 60 and 70 mg/dL may provide a balanced option for those with greater hypoglycemia concerns. These recommendations can optimize system usability and glycemic outcomes while maintaining safety and minimizing alarm burden.Keywords
Funding Information
- Medtronic Europe
This publication has 14 references indexed in Scilit:
- The interdependence of targets for continuous glucose monitoring outcomes in type 1 diabetes with automated insulin deliveryDiabetes, Obesity and Metabolism, 2024
- Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic ControlDiabetes Technology & Therapeutics, 2024
- Celebrating the Data from 100,000 Real-World Users of the MiniMed™ 780G System in Europe, Middle East, and Africa Collected Over 3 Years: From Data to Clinical EvidenceDiabetes Technology & Therapeutics, 2024
- A Peek Under the Hood: Explaining the MiniMed™ 780G Algorithm with Meal Detection TechnologyDiabetes Technology & Therapeutics, 2024
- Intermittent-scanned continuous glucose monitoring with low glucose alarms decreases hypoglycemia incidence in middle-aged adults with type 1 diabetes in real-life settingJournal of Diabetes and its Complications, 2022
- ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Glucose monitoringPediatric Diabetes, 2022
- Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trialThe Lancet Diabetes & Endocrinology, 2019
- Hypoglycemia: New Definitions and Regulatory ImplicationsDiabetes Technology & Therapeutics, 2018
- Characterizing sudden death and dead‐in‐bed syndrome in Type 1 diabetes: analysis from two childhood‐onset Type 1 diabetes registriesDiabetic Medicine, 2010
- Establishing a Continuous Glucose Monitoring ProgramJournal of Diabetes Science and Technology, 2008