An Adaptive Reclosing Scheme for MMC-HVDC Systems Based on Pulse Injection From Parallel Energy Absorption Module
- 10 August 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1809-1818
Abstract
Modular multilevel converter (MMC) based high voltage direct current (HVDC) transmission system is one of the important development trends of DC power grid. After fault isolation, the traditional reclosing method of MMC-HVDC system is directly reclosing DC circuit breaker (DCCB). Once the fault point still exists, DCCB will be tripped again. This method will make the DC system suffer from the secondary strike of fault in a short time, and seriously endanger the service life of DCCB. In order to overcome the drawbacks of the traditional reclosing schemes, this paper proposes a novel adaptive reclosing scheme based on pulse injection from parallel energy absorption module. When dc fault current is interrupted by DCCB, the fault energy stored in current-limiting reactors (CLR) and dc lines is transferred to energy absorption module automatically. By switching on IGBTs embedded in absorption module for a short time, a voltage pulse is injected directly into the faulty line without interference from CLR. Then the nature of fault is identified and the fault distance can also be calculated in the case of permanent faults. The simulation results verify the effectiveness of the proposed scheme.Keywords
Funding Information
- National Key R&D Program of China (2018YFB0904600)
This publication has 18 references indexed in Scilit:
- Analysis of the characteristics of fault‐induced travelling waves in MMC‐HVDC gridThe Journal of Engineering, 2018
- Transient Characteristics Under Ground and Short-Circuit Faults in a ${\pm \text{500}\,\text{kV}}$ MMC-Based HVDC System With Hybrid DC Circuit BreakersIEEE Transactions on Power Delivery, 2018
- Temporary overvoltage mitigation in symmetrical monopole VSC-MMC HVDC links2017
- Comparison of secondary arcs for reclosing applicationsIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- A Pole-to-Pole Short-Circuit Fault Current Calculation Method for DC GridsIEEE Transactions on Power Systems, 2017
- Sequential auto-reclosing method for hybrid HVDC breaker in VSC HVDC links2017
- Time-domain analysis of electromagnetic fields using the fast inverse Laplace transform2016
- Equivalent Electromagnetic Transient Simulation Model and Fast Recovery Control of Overhead VSC-HVDC Based on SB-MMCIEEE Transactions on Power Delivery, 2016
- Research on HVDC single-ended fault traveling wave location method based on FastICA2016
- Implementation and Application of Practical Traveling-Wave-Based Directional Protection in UHV Transmission LinesIEEE Transactions on Power Delivery, 2015