Bingbing Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bingbing Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Guangyao Fan
School of Electrical Engineering, Southeast University, 12579 Nanjing, Jiangsu China
1 shared publication - Jun Mei
School of Electrical Engineering, Southeast University, Nanjing 210096, China
1 shared publication - Lingxiao Yan
School of Electrical Engineering, Southeast University, 12579 Nanjing, Jiangsu China
1 shared publication - Pengfei Zhu
School of Electrical Engineering, Southeast University, 12579 Nanjing, Jiangsu China
1 shared publication - Rui Ge
School of Electrical Engineering, Southeast University, 12579 Nanjing, Jiangsu China
1 shared publication
Latest Publications
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1809-1818
An Adaptive Reclosing Scheme for MMC-HVDC Systems Based on Pulse Injection From Parallel Energy Absorption Module
Modular multilevel converter (MMC) based high voltage direct current (HVDC) transmission system is one of the important development trends of DC power grid. After fault isolation, the traditional reclosing method of MMC-HVDC system is directly reclosing DC circuit breaker (DCCB). Once the fault point still exists, DCCB will be tripped again. This method will make the DC system suffer from the secondary strike of fault in a short time, and seriously endanger the service life of DCCB. In order to overcome the drawbacks of the traditional reclosing schemes, this paper proposes a novel adaptive reclosing scheme based on pulse injection from parallel energy absorption module. When dc fault current is interrupted by DCCB, the fault energy stored in current-limiting reactors (CLR) and dc lines is transferred to energy absorption module automatically. By switching on IGBTs embedded in absorption module for a short time, a voltage pulse is injected directly into the faulty line without interference from CLR. Then the nature of fault is identified and the fault distance can also be calculated in the case of permanent faults. The simulation results verify the effectiveness of the proposed scheme.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (3) , 1809-1818
An Adaptive Reclosing Scheme for MMC-HVDC Systems Based on Pulse Injection From Parallel Energy Absorption Module
Modular multilevel converter (MMC) based high voltage direct current (HVDC) transmission system is one of the important development trends of DC power grid. After fault isolation, the traditional reclosing method of MMC-HVDC system is directly reclosing DC circuit breaker (DCCB). Once the fault point still exists, DCCB will be tripped again. This method will make the DC system suffer from the secondary strike of fault in a short time, and seriously endanger the service life of DCCB. In order to overcome the drawbacks of the traditional reclosing schemes, this paper proposes a novel adaptive reclosing scheme based on pulse injection from parallel energy absorption module. When dc fault current is interrupted by DCCB, the fault energy stored in current-limiting reactors (CLR) and dc lines is transferred to energy absorption module automatically. By switching on IGBTs embedded in absorption module for a short time, a voltage pulse is injected directly into the faulty line without interference from CLR. Then the nature of fault is identified and the fault distance can also be calculated in the case of permanent faults. The simulation results verify the effectiveness of the proposed scheme.