Effects of the Metallic Port in Tissue Expanders on Dose Distribution in Postmastectomy Radiotherapy
- 1 January 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 80 (1) , 67-70
Abstract
The purpose of this research was to develop an experimental model of dosimetry using a breast phantom and evaluate the effects of the metallic port in tissue expanders on dose distribution in postmastectomy radiotherapy. Dose distribution was assessed using an experimental acrylic dosimetry simulator in the absence and presence of a metallic disc (MD), which is similar to that used in tissue expanders containing a magnetic port, by collecting coronal and sagittal radiochromic films. Dosimetry film analysis did not show any changes in dose distribution, except for a MD shadow in the sagittal film where the dose distribution rate was on average 14% lower than in other areas. This model very closely resembled actual breast reconstruction with a tissue expander containing a magnetic port. Scattering or attenuation of the irradiation dose due to interference of the MD was not evident in areas that could jeopardize the effectiveness of radiation therapy. Therefore, the presence of the MD inside the tissue expander does not likely have an impact on radiotherapy effectiveness during immediate breast reconstruction.Keywords
This publication has 12 references indexed in Scilit:
- In vivo dosimetric impact of breast tissue expanders on post‐mastectomy radiotherapyJournal of Medical Imaging and Radiation Oncology, 2015
- Evaluation of the Radiotherapy Treatment Planning in the Presence of a Magnetic Valve Tissue ExpanderPLOS ONE, 2015
- Dosimetric impact of the AeroForm tissue expander in postmastectomy radiation therapy: An ex vivo analysisPractical Radiation Oncology, 2015
- Impact of Internal Metallic Ports in Temporary Tissue Expanders on Postmastectomy Radiation Dose DistributionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- Influence of the Presence of Tissue Expanders on Energy Deposition for Post-Mastectomy RadiotherapyPLOS ONE, 2013
- Do metallic ports in tissue expanders affect postmastectomy radiation delivery?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Postmastectomy RadiotherapyClinical Oncology, 2006
- Investigation into dosimetric effect of a MAGNA‐SITE™ tissue expander on post‐mastectomy radiotherapyMedical Physics, 2005
- Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluationMedical Dosimetry, 2004
- Twenty-Year Follow-up of a Randomized Trial Comparing Total Mastectomy, Lumpectomy, and Lumpectomy plus Irradiation for the Treatment of Invasive Breast CancerThe New England journal of medicine, 2002