Abstract
Input-series-output-parallel (ISOP) LLC-Buck converters are widely used in energy storage systems for their high efficiency and wide voltage gain range. However, parameter mismatches among parallel modules often cause power imbalance and degraded current sharing. This article proposes a model predictive control (MPC) based current sharing strategy for multiphase LLC-Buck converters. A current-sharing error model is established to analyze the impact of mismatched parameters, including resonant components, magnetizing inductance, switch characteristics, and Buck inductor resistance. Based on this, a fixed-frequency, single-step MPC algorithm is developed, incorporating real-time reference updates and an observer to correct model deviations. Compared with the widely used average current control, the proposed method enhances dynamic response, robustness, and current balance. A 500 W two-phase LLC-Buck prototype (48 V to 3.2 V) is built, and both simulation and experimental results validate the approach, achieving current sharing errors of 0.84% at half-load and 0.27% at full-load.
Funding Information
  • National Natural Science Foundation of China (62371233)
  • Jiangsu Provincial Excellent Youth Fund (BK20250179)
  • Fundamental Research Funds for the Central Universities (NE2025003)
  • Postgraduate Research and Practice Innovation Program of NUAA (xcxjh20240313)
  • Jiangsu Provincial Scientific Research and Practice Innovation Program (KYCX250577)