The Orange County Sanitation District (OCSD) scheduled an update of its 2002 Odor Control Master Plan for 2014. The Engineering Planning Division began the assessment project in July 2013, which is to be completed in two separate phases. Phase I will collect the necessary information about the odors present at the different treatment processes at its two plants, and Phase II will evaluate the data through an air dispersion model, write the findings, and propose alternative Level of Service and associated costs in a comprehensive report. This paper discusses Phase I of the project. Odor samples were collected and analyzed chemically and by sensory methods. Chemical analyses included reduced sulfur, carboxylic acids, ammonia, and amines. Sensory analyses by Dilution to Threshold (D/T) provide useful design information only if it can be correlated with a complete set of chemical results. The odor threshold concentration of many odorants is below the method reporting limit of its chemical analyses. Results from the Odor Profile Method (OPM) provide the necessary information gap to identify the key odorants present and direct further efforts to identify hard to detect odorants. Odorants at each of the treatment plant process areas must be identified in order to apply the most effective foul air scrubbing technology to remove them. Odors at OCSD wastewater treatment processes were found to evolve from fecal and sulfur compounds (dominated by H2S) at the headworks and primary treatment, to a complex and hard to define musty, moldy at secondary treatment, and to a prominence of ammonia and amines in solids processing. When H2S is removed by foul air treatment systems, other odorants become dominant, which are challenging for odor treatment.