Irwin H. Suffet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Irwin H. Suffet has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
A. Bruchet
Centre International de Recherche Sur l'Eau et l'Environnement, Suez Environment, Le Pecq, France
4 shared publications- Michael K. Stenstrom
Department of Civil and Environmental Engineering, University of California Los Angeles, Los Angeles, California
4 shared publications - Yubin Zhou
UCLA Department of Environmental Health Sciences, School of Public Health, Los Angeles, CA 90095
4 shared publications - Gary A. Burlingame
Bureau of Laboratory Services, Philadelphia Water Department, 1500 E. Hunting Park Avenue, Philadelphia, PA 19124, United States
3 shared publications - K.E. Wiesenthal
Department of Environmental Health and Science, School of Public Health, University of California at Los Angeles, Los Angeles, CA 90095-1772, USA
3 shared publications - Tadeo Vitko
Orange County Sanitation District, 10844 Ellis Ave., Fountain Valley, CA 92708
3 shared publications
Latest Publications
- Open Access
- 9 April 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (4) , 472
The Use of the Odor Profile Method with an “Odor Patrol” Panel to Evaluate an Odor Impacted Site near a Landfill
A third-party-trained “Odor Patrol” program was conducted at a school that is about a one-mile distance from a landfill to clarify the odor nuisance problems from the landfill. Every 20 min from 6 to 9 a.m. on school days, the “Odor Profile Method” (OPM) was used with the landfill odor wheel to identify the odor type and intensity of each odor type. This study showed that an Odor Patrol using the OPM can accurately define odor nuisance changes over time and can be used as a method to confirm changes of odor nuisances in a field study. The Odor Patrol only found 13 data inputs of the 1000 data inputs (1.3%) for the 100-day odor monitoring with a landfill odor or trash odor that could cause odor complaints. The Odor Patrol data and the Odor Complaint data compared well. The OPM by an “Odor Patrol” could determine the contribution of the nuisance odors from 6 to 9 a.m. at the school site, about one mile away from the landfill. The study demonstrated a novel approach for odor monitoring by using the Odor Profile Method with an Odor Patrol. The OPM not only confirmed the mitigation of a landfill odor problem, but it also determined odor character, odor intensity, odor frequency and odor duration during this study period. “Landfill gas” was determined to be primarily a rotten vegetable odor with a secondary sewery/fecal odor of lower intensity, and “trash odors” were primarily a rancid and sweet odor with a secondary sewery/fecal and/or rotten vegetable odor of lower intensities generated from trash reaching the landfill. The order of intensity observed from high to low was: Trash odor (Rancid–Sweet) > Rotten vegetable > Sewery/Fecal > Rancid. Thus, trash odor is the major problematic odor from the landfill site. Quality assurance methods were used to remove local odors from the evaluation.
- 9 April 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (4) , 472
Open AccessThe Use of the Odor Profile Method with an “Odor Patrol” Panel to Evaluate an Odor Impacted Site near a Landfill
A third-party-trained “Odor Patrol” program was conducted at a school that is about a one-mile distance from a landfill to clarify the odor nuisance problems from the landfill. Every 20 min from 6 to 9 a.m. on school days, the “Odor Profile Method” (OPM) was used with the landfill odor wheel to identify the odor type and intensity of each odor type. This study showed that an Odor Patrol using the OPM can accurately define odor nuisance changes over time and can be used as a method to confirm changes of odor nuisances in a field study. The Odor Patrol only found 13 data inputs of the 1000 data inputs (1.3%) for the 100-day odor monitoring with a landfill odor or trash odor that could cause odor complaints. The Odor Patrol data and the Odor Complaint data compared well. The OPM by an “Odor Patrol” could determine the contribution of the nuisance odors from 6 to 9 a.m. at the school site, about one mile away from the landfill. The study demonstrated a novel approach for odor monitoring by using the Odor Profile Method with an Odor Patrol. The OPM not only confirmed the mitigation of a landfill odor problem, but it also determined odor character, odor intensity, odor frequency and odor duration during this study period. “Landfill gas” was determined to be primarily a rotten vegetable odor with a secondary sewery/fecal odor of lower intensity, and “trash odors” were primarily a rancid and sweet odor with a secondary sewery/fecal and/or rotten vegetable odor of lower intensities generated from trash reaching the landfill. The order of intensity observed from high to low was: Trash odor (Rancid–Sweet) > Rotten vegetable > Sewery/Fecal > Rancid. Thus, trash odor is the major problematic odor from the landfill site. Quality assurance methods were used to remove local odors from the evaluation.
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (4) , 547-562
Characteristics of Nuisance Odor Emissions from the Sludge Drying Process
Sludge drying from wastewater treatment can cause an odor nuisance for neighboring communities. This study characterized the nuisance odor emissions to...
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (4) , 547-562
Characteristics of Nuisance Odor Emissions from the Sludge Drying Process
Sludge drying from wastewater treatment can cause an odor nuisance for neighboring communities. This study characterized the nuisance odor emissions to...
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 December 2016
- Published by Elsevier in Waste Management
- Vol. 58, 52-61
Identification and quantification of nuisance odors at a trash transfer station
- 1 December 2016
- Published by Elsevier in Waste Management
- Vol. 58, 52-61
Identification and quantification of nuisance odors at a trash transfer station
- 1 October 2016
- Published by Elsevier in Water Research
- Vol. 102, 607-618
Predicting runoff induced mass loads in urban watersheds: Linking land use and pyrethroid contamination
- 1 October 2016
- Published by Elsevier in Water Research
- Vol. 102, 607-618
Predicting runoff induced mass loads in urban watersheds: Linking land use and pyrethroid contamination
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 October 2014
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2014 (3) , 1-17
2014 OCSD Odor Control Master Plan
The Orange County Sanitation District (OCSD) scheduled an update of its 2002 Odor Control Master Plan for 2014. The Engineering Planning Division began the assessment project in July 2013, which is to be completed in two separate phases. Phase I will collect the necessary information about the odors present at the different treatment processes at its two plants, and Phase II will evaluate the data through an air dispersion model, write the findings, and propose alternative Level of Service and associated costs in a comprehensive report. This paper discusses Phase I of the project. Odor samples were collected and analyzed chemically and by sensory methods. Chemical analyses included reduced sulfur, carboxylic acids, ammonia, and amines. Sensory analyses by Dilution to Threshold (D/T) provide useful design information only if it can be correlated with a complete set of chemical results. The odor threshold concentration of many odorants is below the method reporting limit of its chemical analyses. Results from the Odor Profile Method (OPM) provide the necessary information gap to identify the key odorants present and direct further efforts to identify hard to detect odorants. Odorants at each of the treatment plant process areas must be identified in order to apply the most effective foul air scrubbing technology to remove them. Odors at OCSD wastewater treatment processes were found to evolve from fecal and sulfur compounds (dominated by H2S) at the headworks and primary treatment, to a complex and hard to define musty, moldy at secondary treatment, and to a prominence of ammonia and amines in solids processing. When H2S is removed by foul air treatment systems, other odorants become dominant, which are challenging for odor treatment.
- 1 October 2014
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2014 (3) , 1-17
2014 OCSD Odor Control Master Plan
The Orange County Sanitation District (OCSD) scheduled an update of its 2002 Odor Control Master Plan for 2014. The Engineering Planning Division began the assessment project in July 2013, which is to be completed in two separate phases. Phase I will collect the necessary information about the odors present at the different treatment processes at its two plants, and Phase II will evaluate the data through an air dispersion model, write the findings, and propose alternative Level of Service and associated costs in a comprehensive report. This paper discusses Phase I of the project. Odor samples were collected and analyzed chemically and by sensory methods. Chemical analyses included reduced sulfur, carboxylic acids, ammonia, and amines. Sensory analyses by Dilution to Threshold (D/T) provide useful design information only if it can be correlated with a complete set of chemical results. The odor threshold concentration of many odorants is below the method reporting limit of its chemical analyses. Results from the Odor Profile Method (OPM) provide the necessary information gap to identify the key odorants present and direct further efforts to identify hard to detect odorants. Odorants at each of the treatment plant process areas must be identified in order to apply the most effective foul air scrubbing technology to remove them. Odors at OCSD wastewater treatment processes were found to evolve from fecal and sulfur compounds (dominated by H2S) at the headworks and primary treatment, to a complex and hard to define musty, moldy at secondary treatment, and to a prominence of ammonia and amines in solids processing. When H2S is removed by foul air treatment systems, other odorants become dominant, which are challenging for odor treatment.
- 1 September 2011
- Published by Elsevier in Science of The Total Environment
- Vol. 409 (19) , 4010-4015
A field studies and modeling approach to develop organochlorine pesticide and PCB total maximum daily load calculations: Case study for Echo Park Lake, Los Angeles, CA
- 1 September 2011
- Published by Elsevier in Science of The Total Environment
- Vol. 409 (19) , 4010-4015
A field studies and modeling approach to develop organochlorine pesticide and PCB total maximum daily load calculations: Case study for Echo Park Lake, Los Angeles, CA