Yubin Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yubin Zhou has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Irwin H. Suffet
Department of Environmental Health Science, UCLA, School of Public Health, Los Angeles, CA 90095, USA
4 shared publications - Tadeo Vitko
Orange County Sanitation District, 10844 Ellis Ave., Fountain Valley, CA 92708
3 shared publications Carla Dillon
Orange County Sanitation District, 10844 Ellis Ave., Fountain Valley, CA 92708
2 shared publicationsJay Witherspoon
CH2M 6 Hutton Center Drive, Suite 700, Santa Ana, CA 92707
2 shared publicationsZeynep Erdal
CH2M 6 Hutton Center Drive, Suite 700, Santa Ana, CA 92707
2 shared publicationsIrwin H. (Mel) Suffet
Department of Environmental Health Sciences, School of Public Health, University of California, Los Angeles, 650Charles E. Young Drive South, 61-296 CHS, Los Angeles, CA, 90095, USA
1 shared publication
Latest Publications
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 September 2016
- Published by Elsevier in Journal of Environmental Management
- Vol. 180, 257-263
Identification, quantification and treatment of fecal odors released into the air at two wastewater treatment plants
- 1 September 2016
- Published by Elsevier in Journal of Environmental Management
- Vol. 180, 257-263
Identification, quantification and treatment of fecal odors released into the air at two wastewater treatment plants
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 October 2014
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2014 (3) , 1-17
2014 OCSD Odor Control Master Plan
The Orange County Sanitation District (OCSD) scheduled an update of its 2002 Odor Control Master Plan for 2014. The Engineering Planning Division began the assessment project in July 2013, which is to be completed in two separate phases. Phase I will collect the necessary information about the odors present at the different treatment processes at its two plants, and Phase II will evaluate the data through an air dispersion model, write the findings, and propose alternative Level of Service and associated costs in a comprehensive report. This paper discusses Phase I of the project. Odor samples were collected and analyzed chemically and by sensory methods. Chemical analyses included reduced sulfur, carboxylic acids, ammonia, and amines. Sensory analyses by Dilution to Threshold (D/T) provide useful design information only if it can be correlated with a complete set of chemical results. The odor threshold concentration of many odorants is below the method reporting limit of its chemical analyses. Results from the Odor Profile Method (OPM) provide the necessary information gap to identify the key odorants present and direct further efforts to identify hard to detect odorants. Odorants at each of the treatment plant process areas must be identified in order to apply the most effective foul air scrubbing technology to remove them. Odors at OCSD wastewater treatment processes were found to evolve from fecal and sulfur compounds (dominated by H2S) at the headworks and primary treatment, to a complex and hard to define musty, moldy at secondary treatment, and to a prominence of ammonia and amines in solids processing. When H2S is removed by foul air treatment systems, other odorants become dominant, which are challenging for odor treatment.
- 1 October 2014
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2014 (3) , 1-17
2014 OCSD Odor Control Master Plan
The Orange County Sanitation District (OCSD) scheduled an update of its 2002 Odor Control Master Plan for 2014. The Engineering Planning Division began the assessment project in July 2013, which is to be completed in two separate phases. Phase I will collect the necessary information about the odors present at the different treatment processes at its two plants, and Phase II will evaluate the data through an air dispersion model, write the findings, and propose alternative Level of Service and associated costs in a comprehensive report. This paper discusses Phase I of the project. Odor samples were collected and analyzed chemically and by sensory methods. Chemical analyses included reduced sulfur, carboxylic acids, ammonia, and amines. Sensory analyses by Dilution to Threshold (D/T) provide useful design information only if it can be correlated with a complete set of chemical results. The odor threshold concentration of many odorants is below the method reporting limit of its chemical analyses. Results from the Odor Profile Method (OPM) provide the necessary information gap to identify the key odorants present and direct further efforts to identify hard to detect odorants. Odorants at each of the treatment plant process areas must be identified in order to apply the most effective foul air scrubbing technology to remove them. Odors at OCSD wastewater treatment processes were found to evolve from fecal and sulfur compounds (dominated by H2S) at the headworks and primary treatment, to a complex and hard to define musty, moldy at secondary treatment, and to a prominence of ammonia and amines in solids processing. When H2S is removed by foul air treatment systems, other odorants become dominant, which are challenging for odor treatment.