Evaluation of Solvents for Dissolution and Electrochemical Detection of Common Lead Forms in Test Drinking Water
Open Access
- 1 December 2025
- journal article
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 4 (4) , 044602
Abstract
Lead contamination in drinking water is a global human health concern. Total lead measurement requires lead dissolution of insoluble lead particles. Standard methods use extensive sample preparation and laboratory-based analysis, unfeasible for point-of-use sensors. Square wave stripping voltammetry using a bismuth-coated electrode has been proposed as a fast, safe, and accurate alternative to standard methods. However, point-of-use lead sensors are limited by a lack of lead dissolution. Lead dissolution of different lead forms in standardized test water with nitric acid at pH 2, hydrochloric acid at pH 2, and acetate buffer at pH 4.5 was investigated. Lead forms common in drinking water were tested and compared to lead nitrate, a form commonly used in laboratory-based studies. The lead dissolution solvents tested were used simultaneously as electrolyte solutions. Measurements were verified by inductively coupled plasma-mass spectrometry. Nitric acid and hydrochloric acid had comparable lead dissolution and sensing for lead forms common in drinking water and real tap water samples. The acids achieved low limits of detection, 1.38 μg l −1 in nitric acid, 6.06 μg l −1 in hydrochloric acid. We conclude nitric acid and hydrochloric acid have the potential to dissolve lead and act as an electrolyte for square wave stripping voltammetry sensing.Keywords
Funding Information
- Social Science Research Council (Sloan Scholars Mentoring Network of the Social Sci)
This publication has 102 references indexed in Scilit:
- Lead pipe andlead–tinsolder scale formation and structure: A conceptual modelAWWA Water Science, 2021
- Water quality–pipe deposit relationships in Midwestern lead pipesAWWA Water Science, 2019
- Performance of a Bismuth Bulk Rotating Disk Electrode for Heavy Metal Analysis: Determination of Lead in Environmental SamplesElectroanalysis, 2012
- Adsorptive Stripping Voltammetry of Nickel at an In Situ Plated Bismuth Film ElectrodeElectroanalysis, 2010
- The Fabrication and Characterization of a Bismuth Nanoparticle Modified Boron Doped Diamond Electrode and Its Application to the Simultaneous Determination of Cadmium(II) And Lead(II)Electroanalysis, 2008
- Effects of Electroplating Variables on the Voltammetric Properties of Bismuth Deposits Plated PotentiostaticallyElectroanalysis, 2006
- Stripping Analysis at Bismuth Electrodes: A ReviewElectroanalysis, 2005
- A Study on Operational Parameters for Advanced Use of Bismuth Film Electrode in Anodic Stripping VoltammetryElectroanalysis, 2002
- A Novelty in Potentiometric Stripping Analysis: Total Replacement of Mercury by BismuthElectroanalysis, 2002
- Response of lead solubility to dissolved carbonate in drinking waterJournal AWWA, 1980