Elizabeth R. Jacobia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elizabeth R. Jacobia has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Akhenaton-Andrew Dhafir Jones
Department of Civil & Environmental Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708
3 shared publications
Latest Publications
- Open Access
- 13 October 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (4) , 045501
Perspective on Electrochemical Lead Detection: Distributed Sensing to Address Unevenly Distributed Risk
Lead contamination is a global issue and requires detection for risk evaluation and remediation. Standardized testing is accurate and effective for water quality monitoring, however, does not provide real-time results and is not widely accessible. Electrochemical detection methods have been developed with comparable lead sensitivity and selectivity to standard methods. United States Environmental Protection Agency certification of electrochemical lead detection methods and inspectors would allow for readily available and cost-efficient water quality results. Introducing electrochemical lead detection methods in the United States will increase water quality awareness, incentivize mitigation, and provide data for regulation and policy development.
- 13 October 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (4) , 045501
Open AccessPerspective on Electrochemical Lead Detection: Distributed Sensing to Address Unevenly Distributed Risk
Lead contamination is a global issue and requires detection for risk evaluation and remediation. Standardized testing is accurate and effective for water quality monitoring, however, does not provide real-time results and is not widely accessible. Electrochemical detection methods have been developed with comparable lead sensitivity and selectivity to standard methods. United States Environmental Protection Agency certification of electrochemical lead detection methods and inspectors would allow for readily available and cost-efficient water quality results. Introducing electrochemical lead detection methods in the United States will increase water quality awareness, incentivize mitigation, and provide data for regulation and policy development.
- Open Access
- 16 July 2026
- Published by Elsevier in SSRN Electronic Journal
Characterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection
Lead detection is needed to assess water quality risks, evaluate potential human exposure to lead, and guide effective resource allocation. Bismuth-coated electrodes have been employed for trace lead detection in drinking water samples because they can be made portable and are a safer alternative to mercury-based electrodes. Alternative electrolytes to the standard acetate buffer electrolyte can simplify the detection method and ensure the complete dissolution of particulate lead, a substantial portion of total lead, in drinking water samples. Acids are effective in dissolving particulate lead but are not common electrolytes for lead detection using bismuth-coated electrodes because it is hypothesized that they disrupt the coating. We tested this hypothesis in nitric, hydrochloric, acetate buffer, and sodium chloride electrolytes using square wave stripping voltammetry (SWSV), open circuit potential (OCP), cyclic voltammetry (CV), electrochemically active surface area calculations, and electrochemical impedance spectroscopy (EIS) to determine the electrochemical and electrical properties of bismuth-coated rotating disk electrodes in each. Nitric Acid had the lowest percent relative standard deviation (RSD) between lead peak repeated measures of the electrolytes (2.82 ± 0.947%), the highest OCP value (-0.0170 ± 0.0157 V), and moderate calculated electrochemically active surface area (0.0316 ± 0.0136 cm2) and roughness factor values (0.161 ± 0.069 cm2). Uncompensated resistance (168.82 ± 2.22 ohms) and polarization resistance (1387.41 ± 67.75 ohms) in nitric acid was low compared to the other electrolytes tested. Nitric acid had the highest EIS magnitude parameters for electrical surface distribution (5.5x10-4 ± 2.8x10-5 S•sα) and non-ideal capacitor coefficient (0.713 ± 0.006). The bismuth-coated electrode enabled a 60.3% increase in sensitivity compared to the bare electrode in nitric acid. We conclude that nitric acid is an effective alternative electrolyte for lead detection on bismuth-coated glassy carbon electrodes due to its low pH and minimal complexation with lead ions.
- 16 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCharacterization of Bismuth-Coated Glassy Carbon Electrodes in Acidic Solvent Electrolytes for Enhanced Lead Detection
Lead detection is needed to assess water quality risks, evaluate potential human exposure to lead, and guide effective resource allocation. Bismuth-coated electrodes have been employed for trace lead detection in drinking water samples because they can be made portable and are a safer alternative to mercury-based electrodes. Alternative electrolytes to the standard acetate buffer electrolyte can simplify the detection method and ensure the complete dissolution of particulate lead, a substantial portion of total lead, in drinking water samples. Acids are effective in dissolving particulate lead but are not common electrolytes for lead detection using bismuth-coated electrodes because it is hypothesized that they disrupt the coating. We tested this hypothesis in nitric, hydrochloric, acetate buffer, and sodium chloride electrolytes using square wave stripping voltammetry (SWSV), open circuit potential (OCP), cyclic voltammetry (CV), electrochemically active surface area calculations, and electrochemical impedance spectroscopy (EIS) to determine the electrochemical and electrical properties of bismuth-coated rotating disk electrodes in each. Nitric Acid had the lowest percent relative standard deviation (RSD) between lead peak repeated measures of the electrolytes (2.82 ± 0.947%), the highest OCP value (-0.0170 ± 0.0157 V), and moderate calculated electrochemically active surface area (0.0316 ± 0.0136 cm2) and roughness factor values (0.161 ± 0.069 cm2). Uncompensated resistance (168.82 ± 2.22 ohms) and polarization resistance (1387.41 ± 67.75 ohms) in nitric acid was low compared to the other electrolytes tested. Nitric acid had the highest EIS magnitude parameters for electrical surface distribution (5.5x10-4 ± 2.8x10-5 S•sα) and non-ideal capacitor coefficient (0.713 ± 0.006). The bismuth-coated electrode enabled a 60.3% increase in sensitivity compared to the bare electrode in nitric acid. We conclude that nitric acid is an effective alternative electrolyte for lead detection on bismuth-coated glassy carbon electrodes due to its low pH and minimal complexation with lead ions.
- Open Access
- 1 December 2025
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 4 (4) , 044602
Evaluation of Solvents for Dissolution and Electrochemical Detection of Common Lead Forms in Test Drinking Water
Lead contamination in drinking water is a global human health concern. Total lead measurement requires lead dissolution of insoluble lead particles. Standard methods use extensive sample preparation and laboratory-based analysis, unfeasible for point-of-use sensors. Square wave stripping voltammetry using a bismuth-coated electrode has been proposed as a fast, safe, and accurate alternative to standard methods. However, point-of-use lead sensors are limited by a lack of lead dissolution. Lead dissolution of different lead forms in standardized test water with nitric acid at pH 2, hydrochloric acid at pH 2, and acetate buffer at pH 4.5 was investigated. Lead forms common in drinking water were tested and compared to lead nitrate, a form commonly used in laboratory-based studies. The lead dissolution solvents tested were used simultaneously as electrolyte solutions. Measurements were verified by inductively coupled plasma-mass spectrometry. Nitric acid and hydrochloric acid had comparable lead dissolution and sensing for lead forms common in drinking water and real tap water samples. The acids achieved low limits of detection, 1.38 μg l −1 in nitric acid, 6.06 μg l −1 in hydrochloric acid. We conclude nitric acid and hydrochloric acid have the potential to dissolve lead and act as an electrolyte for square wave stripping voltammetry sensing.
- 1 December 2025
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 4 (4) , 044602
Open AccessEvaluation of Solvents for Dissolution and Electrochemical Detection of Common Lead Forms in Test Drinking Water
Lead contamination in drinking water is a global human health concern. Total lead measurement requires lead dissolution of insoluble lead particles. Standard methods use extensive sample preparation and laboratory-based analysis, unfeasible for point-of-use sensors. Square wave stripping voltammetry using a bismuth-coated electrode has been proposed as a fast, safe, and accurate alternative to standard methods. However, point-of-use lead sensors are limited by a lack of lead dissolution. Lead dissolution of different lead forms in standardized test water with nitric acid at pH 2, hydrochloric acid at pH 2, and acetate buffer at pH 4.5 was investigated. Lead forms common in drinking water were tested and compared to lead nitrate, a form commonly used in laboratory-based studies. The lead dissolution solvents tested were used simultaneously as electrolyte solutions. Measurements were verified by inductively coupled plasma-mass spectrometry. Nitric acid and hydrochloric acid had comparable lead dissolution and sensing for lead forms common in drinking water and real tap water samples. The acids achieved low limits of detection, 1.38 μg l −1 in nitric acid, 6.06 μg l −1 in hydrochloric acid. We conclude nitric acid and hydrochloric acid have the potential to dissolve lead and act as an electrolyte for square wave stripping voltammetry sensing.