Compensation of inhomogeneous fluorescence signal distribution in 2D images acquired by confocal microscopy
- 3 December 2010
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (9) , 831-838
Abstract
In images acquired by confocal laser scanning microscopy (CLSM), regions corresponding to the same concentration of fluorophores in the specimen should be mapped to the same grayscale levels. However, in practice, due to multiple distortion effects, CLSM images of even homogeneous specimen regions suffer from irregular brightness variations, e.g., darkening of image edges and lightening of the center. The effects are yet more pronounced in images of real biological specimens. A spatially varying grayscale map complicates image postprocessing, e.g., in alignment of overlapping regions of two images and in 3D reconstructions, since measures of similarity usually assume a spatially independent grayscale map. We present a fast correction method based on estimating a spatially variable illumination gain, and multiplying acquired CLSM images by the inverse of the estimated gain. The method does not require any special calibration of reference images since the gain estimate is extracted from the CLSM image being corrected itself. The proposed approach exploits two types of morphological filters: the median filter and the upper Lipschitz cover. The presented correction method, tested on images of both artificial (homogeneous fluorescent layer) and real biological specimens, namely sections of a rat embryo and a rat brain, proved to be very fast and yielded a significant visual improvement. Microsc. Res. Tech., 2011.Keywords
This publication has 13 references indexed in Scilit:
- High-LET Radiation-Induced Response of Microvessels in the HippocampusRadiation Research, 2010
- Volume reconstruction of large tissue specimens from serial physical sections using confocal microscopy and correction of cutting deformations by elastic registrationMicroscopy Research and Technique, 2009
- A statistical approach for intensity loss compensation of confocal microscopy imagesJournal of Microscopy, 2008
- Image heterogeneity correction in large-area, three-dimensional multiphoton microscopy.Optics Express, 2008
- Median Filtering in Constant TimeIEEE Transactions on Image Processing, 2007
- Methods for compensation of the light attenuation with depth of images captured by a confocal microscopeMicroscopy Research and Technique, 2006
- Intensity correction of fluorescent confocal laser scanning microscope images by mean‐weight filteringJournal of Microscopy, 2006
- Three-dimensional reconstructions from non-deparaffinized tissue sectionsBrain Structure and Function, 2005
- Three‐dimensional computer reconstruction of large tissue volumes based on composing series of high‐resolution confocal images by GlueMRC and LinkMRC softwareMicroscopy Research and Technique, 2003
- Methods for large data volumes from confocal scanning laser microscopy of lungJournal of Microscopy, 1993