A confocal laser scanning microscope (CLSM) enables us to capture images from a biological specimen in different depths and obtain a series of precisely registered fluorescent images. However, images captured from deep layers of the specimen may be darker than images from the topmost layers because of light loss distortions. This effect causes difficulties in subsequent analysis of biological objects. We propose a solution using two approaches: either an online method working already during image acquisition or an offline method assisting as a postprocessing step. In the online method, the gain value of a photomultiplier tube of a CLSM is controlled according to the difference of mean image intensities between the reference and currently acquired image. The offline method consists of two stages. In the first stage, a standard histogram maintaining relative frequencies of gray levels and improving brightness and contrast is created from all images in the series. In the second stage, individual image histograms are warped according to this standard histogram. The methods were tested on real confocal image data captured from human placenta and rat skeletal muscle specimens. It was shown that both approaches diminish the light attenuation in images captured from deep layers of the specimen. Microsc. Res. Tech., 2006.Keywords
This publication has 20 references indexed in Scilit:
- Improvement in volume estimation from confocal sections after image deconvolutionMicroscopy Research and Technique, 2004
- Robust incremental compensation of the light attenuation with depth in 3D fluorescence microscopyJournal of Microscopy, 2004
- Topological Properties and Spatial Organization of Villous Capillaries in Normal and Diabetic PlacentasJournal of Vascular Research, 2002
- Image Restoration for Confocal Microscopy: Improving the Limits of Deconvolution, with Application to the Visualization of the Mammalian Hearing OrganBiophysical Journal, 2001
- New variants of a method of MRI scale standardizationIEEE Transactions on Medical Imaging, 2000
- Fluorescence photobleaching‐based shading correction for fluorescence microscopyJournal of Microscopy, 1998
- Revised definition of optical flow: integration of radiometric and geometric cues for dynamic scene analysisIEEE Transactions on Pattern Analysis and Machine Intelligence, 1998
- A precise light attenuation correction for confocal scanning microscopy withO(n4/3)computing time andO(n)memory requirements fornvoxelsJournal of Microscopy, 1996
- A method to compensate for light attenuation with depth in three‐dimensional DNA image cytometry using a confocal scanning laser microscopeJournal of Microscopy, 1995
- Handbook of Biological Confocal Microscopy1995