Effect of Various Retentive Element Materials on Retention of Mandibular Implant-Retained Overdentures
Open Access
Abstract
This study aimed to examine the retentive characteristics of each retentive element material and the effects from thermocycling using the two implant-retained mandibular overdenture model. Two stud abutments and three retentive element materials; nylon, polyetheretherketone (PEEK) and polyvinylsiloxane (PVS) were used in this study. Four tested groups, with a total of 40 overdentures, were fabricated, including a Locator® abutment with nylon retention insert (NY), Novaloc® abutment with PEEK retention insert (PK), Locator® abutment with PVS retention insert (RL), and Novaloc® abutment with PVS retention insert (RN). The retentive force (N) was measured before thermocycling, and at 2500, 5000, and 10,000 cycles after thermocycling. Significant changes in the percentage of retention loss were found in the NY and PK groups (p < 0.05) at 6 and 12 months for the RL group (p < 0.05) after artificial aging. The RN group exhibited a constant retentive force (p > 0.05). The tendency of the percentage of retention loss significantly increased for PEEK, nylon, and PVS silicone over time. The results of the present study implied that retentive element materials tend to lose their retentive capability as a result of thermal undulation and water dispersion. Nylon and PEEK, comprising strong polar groups in polymer chains, showed a higher rate of retention loss than polyvinylsiloxane.Keywords
This publication has 39 references indexed in Scilit:
- Refusal of implant supported mandibular overdentures by elderly patientsGerodontology, 2011
- Effect of simulated masticatory loading on the retention of stud attachments for implant overdenturesJournal of Oral Rehabilitation, 2010
- A Comparison of Three Different Attachment Systems for Mandibular Two‐Implant Overdentures: One‐Year ReportClinical Implant Dentistry and Related Research, 2010
- Effect of thermocycling and treatment with monomer on mechanical properties of soft denture liner Molloplast BInternational Journal of Adhesion and Adhesives, 2009
- Is there a certain number of implants needed to retain an overdenture?Journal of Oral Rehabilitation, 2007
- Influence of attachment wear on retention of mandibular overdentureJournal of Oral Rehabilitation, 2006
- Attachment Systems for Implant Retained Overdentures: A Literature ReviewImplant Dentistry, 2006
- Tribology of polymers: Adhesion, friction, wear, and mass-transferTribology International, 2005
- Retention Characteristics of Attachment Systems for Implant OverdenturesJournal of Prosthodontics, 2004
- Effect of water absorption in polymers at low and high temperaturesPolymer, 1999