Abstract
The image quality and spectral accuracy of magnetic resonance imaging (MRI) are highly dependent on the homogeneity of the static magnetic field (B0). In compact 3 T animal MRI systems, susceptibility effects and geometric constraints tend to amplify magnetic field distortions, making efficient shimming particularly essential. Passive shimming corrects field inhomogeneity by strategically placing ferromagnetic materials in shim trays, offering advantages such as structural simplicity and low cost. However, the relative performance of various passive shimming strategies has not been systematically evaluated. In this study, we compared two typical passive shimming methods using a 3 T animal MRI superconducting magnet: 1) Odd-even progressive shimming method, in which the odd and even shim trays are adjusted alternatively in two successive rounds (method I), and 2) overall iterative shimming method, where all shim trays are optimized simultaneously in each round with iterative refinement based on prior results (method II). Magnetic field mapping and quantitative analysis were used to assess shimming performance. The results indicate that the overall iterative method provides higher efficiency. After two rounds, field inhomogeneity decreased from 1174.63 ppm to 87.37 ppm using method I, while method II achieved 54.30 ppm—a 37.8% improvement. Theoretically, method II can reduce residual inhomogeneity to approximately 5.91 ppm, indicating higher theoretical shimming potential for the present compact small-bore magnet. The overall iterative method is recommended as an effective and practical solution for improving magnetic field homogeneity and image quality in compact animal MRI systems.Keywords
Funding Information
- Beijing Key Laboratory of Applied Superconductivity
- National Natural Science Foundation of China (52277031)
- National Natural Science Foundation of China (52293420)
- National Natural Science Foundation of China (52293421)
- National Natural Science Foundation of China (52293422)
- National Natural Science Foundation of China (52293423)
- National Natural Science Foundation of China (51777205)
This publication has 25 references indexed in Scilit:
- Structural design and analysis of 7 T active-shield animal MRI magnet systemPhysica C: Superconductivity and its Applications, 2024
- Ultrahigh-field animal MRI system with advanced technological updatenpj Imaging, 2024
- A hybrid, nonlinear programming approach for optimizing passive shimming in MRIMedical Physics, 2024
- An easy-built Halbach magnet for LF-NMR with high homogeneity using optimized target-field passive shimming methodJournal of Magnetic Resonance, 2023
- On the passive shimming of a 7 T whole‐body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force controlMedical Physics, 2023
- Hybrid active and passive local shimming (HAPLS) for two‐region MRIMagnetic Resonance in Medicine, 2022
- Electromagnetic computation and modeling in MRIMedical Physics, 2017
- A Ferromagnetic Shimming Method for NMR/MRI Magnets Adopting Two Consecutive Optimization Techniques: Linear Programming and Evolution StrategyJournal of Superconductivity and Novel Magnetism, 2010
- Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fieldsJournal of Magnetic Resonance, 2006
- Sample-specific diamagnetic and paramagnetic passive shimmingJournal of Magnetic Resonance, 2006