ZWZheng Wang

Zheng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zheng Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Practical Two-Stage Passive Shimming Approach for HTS MRI Magnet

    by Jiahao Li, Qiuliang Wang, Jianhua Liu, Kangshuai Wang, Zheng Wang, Tianyang Feng, Zili Zhang, Lei Wang, Lei Qi

  • Enhancement of Low-Field Neck MRI Using a Two-Turn Solenoid Coil Integrated With a Conformal Spiral Metasurface

    by Ce Xiang, Hongyan He, Lei Li, Chengwei Lu, Shufeng Wei, Huixian Wang, Zheng Wang, Qiuliang Wang, Wenhui Yang

  • Comparison of Passive Shimming Strategies: Overall versus Odd-Even Shim Tray Operation in a 3T Animal MRI Superconducting Magnet

    by Haotian Miao, Wenchen Wang, Guyue Zhou, Shunzhong Chen, Hui Wang, Wenhui Yang, Zheng Wang, Haoran Chen, Feng Liu, Xiaowei Song, et al.

    The image quality and spectral accuracy of magnetic resonance imaging (MRI) are highly dependent on the homogeneity of the static magnetic field (B0). In compact 3 T animal MRI systems, susceptibility effects and geometric constraints tend to amplify magnetic field distortions, making efficient shimming particularly essential. Passive shimming corrects field inhomogeneity by strategically placing ferromagnetic materials in shim trays, offering advantages such as structural simplicity and low cost. However, the relative performance of various passive shimming strategies has not been systematically evaluated. In this study, we compared two typical passive shimming methods using a 3 T animal MRI superconducting magnet: 1) Odd-even progressive shimming method, in which the odd and even shim trays are adjusted alternatively in two successive rounds (method I), and 2) overall iterative shimming method, where all shim trays are optimized simultaneously in each round with iterative refinement based on prior results (method II). Magnetic field mapping and quantitative analysis were used to assess shimming performance. The results indicate that the overall iterative method provides higher efficiency. After two rounds, field inhomogeneity decreased from 1174.63 ppm to 87.37 ppm using method I, while method II achieved 54.30 ppm—a 37.8% improvement. Theoretically, method II can reduce residual inhomogeneity to approximately 5.91 ppm, indicating higher theoretical shimming potential for the present compact small-bore magnet. The overall iterative method is recommended as an effective and practical solution for improving magnetic field homogeneity and image quality in compact animal MRI systems.

  • A hybrid gradient coil design method generating ultra-high gradient magnetic field for micro-MRI utilization

    by Hongyan He, Yaohui Wang, Zheng Wang, Shufeng Wei, Huixian Wang, Feng Liu, Wenhui Yang, Qiuliang Wang

    Ultra-high gradient strength is crucial for achieving high spatial resolution in advanced magnetic resonance imaging (MRI) applications. However, it is challenging to design gradient coils to generate ultra-high gradient strengths with superior coil operational efficiency in a limited space. In this work, we propose an innovative hybrid gradient coil design approach that synergistically integrates the discrete wire scheme with the current density technique. The primary coils are configured using a discrete wire technique that achieves a compact and high-density winding structure, generating exceptional gradient field intensity. Concurrently, the shielding layer utilizes the current density method and stream function to effectively constrain stray magnetic fields and eddy current effects. Comparative analysis with conventional gradient coils demonstrates that the hybrid design approach achieves a doubling of gradient strength (e.g., 2450 vs 1000 mT/m) and a quadrupling of efficiency (e.g., 49 vs 12 mT/m/A). Furthermore, the mechanical design is also analyzed to ensure structural integrity and manufacturability. This novel design method provides new insights into overcoming the trade-offs among gradient performance metrics, establishing a promising approach for developing new-generation high-resolution MRI systems.

  • 2-D and 3-D Analytical Calculation of the Magnetic Field and Levitation Force Between Two Halbach Permanent Magnet Arrays

    by Wenbing Tang, Liye Xiao, Dong Xia, Wenhui Yang, Zheng Wang

    As we know, the analytical calculation of magnetic field and magnetic force has important guiding significance for the optimal design of the size and structure of a magnet. At present, the magnetic field and magnetic force between two permanent magnet (PM) monomers have been described by effective analytical models. However, the magnetic field strength and magnetic force generated by two PM monomers are limited and cannot meet the requirements of a PM levitation system with high magnetic field strength and large levitation force. To this end, this article establishes analytical calculation models of magnetic field and levitation force between two Halbach PM arrays. First, on the basis of Ampere molecular circulation hypothesis, the 2-D analytical model of magnetic field was established based on the surface current method; on the basis of magnetic charge theory, the 3-D analytical model of magnetic field was established based on the magnetic charge method. Second, based on the analytical models of magnetic field, the 2-D and 3-D analytic models of levitation force were derived by virtual work method, respectively. Numerically, the results of two analytical models of magnetic field and two analytical models of levitation force have been compared to verify the accuracy of the models. At the same time, the 2-D and 3-D finite element simulation models of magnetic field and levitation force were established, respectively, and the accuracy of the analytical models were verified again. The results show that the analytical models established in this article is effective and can be used to guide the design and optimization of the magnet composed of two Halbach arrays.