Improving Xenon‐129 lung ventilation image SNR with deep‐learning based image reconstruction
Open Access
- 18 August 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
Abstract
Purpose: To evaluate the feasibility and utility of a deep learning (DL)‐based reconstruction for improving the SNR of hyperpolarized 129Xe lung ventilation MRI.Methods: 129Xe lung ventilation MRI data acquired from patients with asthma and/or chronic obstructive pulmonary disease (COPD) were retrospectively reconstructed with a commercial DL reconstruction pipeline at five different denoising levels. Quantitative imaging metrics of lung ventilation including ventilation defect percentage (VDP) and ventilation heterogeneity index (VHI) were compared between each set of DL‐reconstructed images and alternative denoising strategies including: filtering, total variation denoising and higher‐order singular value decomposition. Structural similarity between the denoised and original images was assessed. In a prospective study, the feasibility of using SNR gains from DL reconstruction to allow natural‐abundance xenon MRI was evaluated in healthy volunteers.Results: 129Xe ventilation image SNR was improved with DL reconstruction when compared with conventionally reconstructed images. In patients with asthma and/or COPD, DL‐reconstructed images exhibited a slight positive bias in ventilation defect percentage (1.3% at 75% denoising) and ventilation heterogeneity index (˜1.4) when compared with conventionally reconstructed images. Additionally, DL‐reconstructed images preserved structural similarity more effectively than data denoised using alternative approaches. DL reconstruction greatly improved image SNR (greater than threefold), to a level that 129Xe ventilation imaging using natural‐abundance xenon appears feasible.Conclusion: DL‐based image reconstruction significantly improves 129Xe ventilation image SNR, preserves structural similarity, and leads to a minor bias in ventilation metrics that can be attributed to differences in the image sharpness. This tool should help facilitate cost‐effective 129Xe ventilation imaging with natural‐abundance xenon in the future.Keywords
Funding Information
- UK Research and Innovation (MR/W008556/1)
- Engineering and Physical Sciences Research Council (EP/X025187/1)
This publication has 28 references indexed in Scilit:
- A 3D stack‐of‐spirals approach for rapid hyperpolarized 129Xe ventilation mapping in pediatric cystic fibrosis lung diseaseMagnetic Resonance in Medicine, 2022
- Fast T2‐Weighted Imaging With Deep Learning‐Based Reconstruction: Evaluation of Image Quality and Diagnostic Performance in Patients Undergoing Radical ProstatectomyJournal of Magnetic Resonance Imaging, 2021
- Dissolved 129Xe lung MRI with four‐echo 3D radial spectroscopic imaging: Quantification of regional gas transfer in idiopathic pulmonary fibrosisMagnetic Resonance in Medicine, 2020
- Improved pulmonary 129Xe ventilation imaging via 3D‐spiral UTE MRIMagnetic Resonance in Medicine, 2019
- Fast and accurate reconstruction of human lung gas MRI with deep learningMagnetic Resonance in Medicine, 2019
- Single breath‐held acquisition of coregistered 3D 129Xe lung ventilation and anatomical proton images of the human lung with compressed sensingMagnetic Resonance in Medicine, 2019
- Single‐breath clinical imaging of hyperpolarized 129xe in the airspaces, barrier, and red blood cells using an interleaved 3D radial 1‐point Dixon acquisitionMagnetic Resonance in Medicine, 2015
- Feasibility of human lung ventilation imaging using highly polarized naturally abundant xenon and optimized three‐dimensional steady‐state free precessionMagnetic Resonance in Medicine, 2015
- 32‐channel phased‐array receive with asymmetric birdcage transmit coil for hyperpolarized xenon‐129 lung imagingMagnetic Resonance in Medicine, 2012
- The rician distribution of noisy mri dataMagnetic Resonance in Medicine, 1995