Design of a Six-Story Teaching Building: A Comprehensive Approach to Safety and Structural Efficiency
Open Access
- 1 September 2024
- journal article
- Published by AMO Publisher in European Journal of Theoretical and Applied Sciences
- Vol. 2 (5) , 593-619
Abstract
This paper describes teaching building design. The project, designed for the teaching building, prioritizes safety in its main structure, a reinforced concrete frame with six floors above ground. The story heights are 4.2m, 3.9m, 3.9m, 3.9m, 3.9m and 3.9m, respectively, and the building's total height is 27.6m. The construction site category is classified as type II, and the first group's seismic fortification intensity is 7 degrees. The process includes architectural design, structural design, and PKPM checking calculation. Architectural design mainly consists of a general description. The plan, elevation, section, and draft of the corresponding building are drawn according to the relevant information and requirements provided by the design task book. Structural design mainly includes load statistics, calculation of internal force and displacement of the frame, a combination of internal force, and calculation of staircase, slab roof, floor slab and frame structure. The calculation of displacement, internal force, and reinforcement of the whole frame structure is carried. Out using PKPM. In the course of architectural design, safety is a paramount consideration, in line with the principles of safety, applicability, beauty, economy, and energy-saving requirements, referring to national standards and relevant materials, and strictly following the requirements of relevant architectural design standards, the design of each link is not only a comprehensive scientific consideration of its own but also a related discussion with teachers, as detailed in the construction plan. The frame structure is adopted,in this structural type. It mainly includes structure layout and calculation sketch determination, load calculation, internal force calculation, internal force combination, main beam section design, and reinforcement calculation, frame column section design and reinforcement calculation, secondary beam section design and reinforcement calculation, floor and roof design, staircase design etc. Among them, the D-value method is used to calculate the internal force of the structure under horizontal load, and the distribution method is used to calculate the internal force of the structure under vertical load (dead load and live load).Keywords
This publication has 18 references indexed in Scilit:
- Structural response of modular buildings – An overviewJournal of Building Engineering, 2018
- Experimental study on interior connections in modular steel buildingsEngineering Structures, 2017
- Application of Modular Construction in High-Rise BuildingsJournal of Architectural Engineering, 2012
- An effective component-based method to model semi-rigid connections for the global analysis of steel and composite structuresEngineering Structures, 2006
- Post-limit stiffness and ductility of end-plate beam-to-column steel jointsComputers & Structures, 2002
- ANALYTICAL MODELLING OF THE SEISMIC BEHAVIOUR OF PRECAST CONCRETE FRAMES DESIGNED WITH DUCTILE CONNECTIONSJournal of Earthquake Engineering, 2001
- Non-linear analysis of steel plane frames with semirigid connectionsJournal of Constructional Steel Research, 1998
- Frame analysis with panel zone deformationInternational Journal of Solids and Structures, 1986
- Mechanistic Seismic Damage Model for Reinforced ConcreteJournal of Structural Engineering, 1985
- Shear Requirements for Load Reversals on RC MembersJournal of the Structural Division, 1977