Mechanism of Low-Frequency Oscillation When Electric Multiple Units Pass Neutral Zone, and Suppression Method
Open Access
Abstract
This article addresses the problem of the contact voltage increase caused by the low-frequency oscillation of the train-grid system in the phase-separation process of EMUs. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and ascertains the relationship between the phase angle when the pantograph leaves the line, and low-frequency oscillations. Methods to suppress overvoltage during the low-frequency oscillation are proposed. The research indicated that a significant voltage amplitude was observed in the neutral zone, when the phase angle of the pantograph to the contact line separation power supply fell within the range of 60–90° and 240–270°. The maximum voltage amplitude reached 69.75 kV, and there was an occurrence of low-frequency oscillation in the neutral zone, where electrical phase separation takes place. During this oscillation, the voltage of the contact network in the neutral zone mainly operated at one-third of the power frequency (16.7 Hz). However, after installing an RC suppression device in the neutral zone, when low-frequency oscillation occurred, the absolute value of the peak voltage dropped below 37 kV as soon as the EMU entered electric phase separation. Furthermore, compared to situations without a connected suppression device, there was nearly a 30% reduction in the absolute value of the peak voltage. The study provides a basis for the design of the neutral zone of the contact line, and the selection of high-voltage equipment for the EMU.Keywords
All Related Versions
Funding Information
- Fundamental Research Funds for the Central Universities (2021JBM025, 51907003, SHSN-22-05, SHTL-21-08)
- National Natural Science Foundation of China (2021JBM025, 51907003, SHSN-22-05, SHTL-21-08)
- Science and Technology Project of National Energy Group (2021JBM025, 51907003, SHSN-22-05, SHTL-21-08)
This publication has 32 references indexed in Scilit:
- Duality Derived Transformer Models for Low-Frequency Electromagnetic Transients—Part I: Topological ModelsIEEE Transactions on Power Delivery, 2016
- Researches on DC modulation to damp low frequency oscillation in China Southern Power Grid2015
- A survey on hysteresis modeling, identification and controlMechanical Systems and Signal Processing, 2014
- Over-Voltage Suppression of Electric Railway Articulated Neutral InsulatorAdvanced Materials Research, 2013
- Comparing the T and $\pi$ Equivalent Circuits for the Calculation of Transformer Inrush CurrentsIEEE Transactions on Power Delivery, 2012
- A New Method to Model the Harmonic Generation Characteristics of the Thyristor Controlled Reactors2007
- Transformer Modeling for Low- and Mid-Frequency Transients—A ReviewIEEE Transactions on Power Delivery, 2005
- Hysteresis modeling in the MATLAB/Power System BlocksetMathematics and Computers in Simulation, 2003
- Hydraulic turbine and turbine control models for system dynamic studiesIEEE Transactions on Power Systems, 1992
- Quasi-static limit for the propagating mode along a thin wire in a circular tunnelIEEE Transactions on Antennas and Propagation, 1977