Shengchun Yan
Research Subjects
Shengchun Yan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jiyong Liu
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
6 shared publications - Jixing Sun
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
5 shared publications - Kaixuan Hu
School of Electrical Engineering, Beijing Jiaotong University, No. 3 Shangyuancun in Haidian District, Beijing 100044, China
4 shared publications - Yan Zhang
Shuohuang Railway Development Co., Ltd. of National Energy, Cangzhou 062350, China
4 shared publications - Kun Zhang
School of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
3 shared publications - Yongzhi Fan
Institute of Electrical Engineering, Beijing Jiaotong University, Haidian District, Beijing 100044, China
3 shared publications
Latest Publications
- Open Access
Characterization of the Airflow Distribution near a Circuit Breaker’s Cu-Ag-Alloy Electrode Surface during and after Breakdown
Circuit breakers, affected by multiple lightning strikes after the breaker has been tripped, can break down again, which will reduce the life of the circuit breaker and threaten the stable operation of the power system. Aiming at this problem, this research obtained the temperature diffusion process of the inrush current process of the circuit breaker’s opening and breaking, using the Schlieren technique combined with existing image recognition technology to obtain the temperature characteristics of the airflow in the air gap of the contact, as well as the characteristics of the flow of air itself. The results of the study show that the circuit breaker breakdown process generates a shock wave with a velocity approximately equal to the speed of sound under the same conditions. The maximum velocity of the airflow boundary diffusion is about one-quarter of the speed of sound under the same condition, and it decays very fast, reducing to the airflow drift velocity within 10 ms after breakdown. The maximum temperature of the thermals is concentrated between 6000 K and 8000 K, and the temperature change is approximately inversely proportional to the square of the time. This research provides the basis for the design of a circuit breaker’s contact structure, opening speed optimization method, interrupter chamber, and insulation design optimization.
Open AccessCharacterization of the Airflow Distribution near a Circuit Breaker’s Cu-Ag-Alloy Electrode Surface during and after Breakdown
Circuit breakers, affected by multiple lightning strikes after the breaker has been tripped, can break down again, which will reduce the life of the circuit breaker and threaten the stable operation of the power system. Aiming at this problem, this research obtained the temperature diffusion process of the inrush current process of the circuit breaker’s opening and breaking, using the Schlieren technique combined with existing image recognition technology to obtain the temperature characteristics of the airflow in the air gap of the contact, as well as the characteristics of the flow of air itself. The results of the study show that the circuit breaker breakdown process generates a shock wave with a velocity approximately equal to the speed of sound under the same conditions. The maximum velocity of the airflow boundary diffusion is about one-quarter of the speed of sound under the same condition, and it decays very fast, reducing to the airflow drift velocity within 10 ms after breakdown. The maximum temperature of the thermals is concentrated between 6000 K and 8000 K, and the temperature change is approximately inversely proportional to the square of the time. This research provides the basis for the design of a circuit breaker’s contact structure, opening speed optimization method, interrupter chamber, and insulation design optimization.
- Open Access
Mechanism of Low-Frequency Oscillation When Electric Multiple Units Pass Neutral Zone, and Suppression Method
This article addresses the problem of the contact voltage increase caused by the low-frequency oscillation of the train-grid system in the phase-separation process of EMUs. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and ascertains the relationship between the phase angle when the pantograph leaves the line, and low-frequency oscillations. Methods to suppress overvoltage during the low-frequency oscillation are proposed. The research indicated that a significant voltage amplitude was observed in the neutral zone, when the phase angle of the pantograph to the contact line separation power supply fell within the range of 60–90° and 240–270°. The maximum voltage amplitude reached 69.75 kV, and there was an occurrence of low-frequency oscillation in the neutral zone, where electrical phase separation takes place. During this oscillation, the voltage of the contact network in the neutral zone mainly operated at one-third of the power frequency (16.7 Hz). However, after installing an RC suppression device in the neutral zone, when low-frequency oscillation occurred, the absolute value of the peak voltage dropped below 37 kV as soon as the EMU entered electric phase separation. Furthermore, compared to situations without a connected suppression device, there was nearly a 30% reduction in the absolute value of the peak voltage. The study provides a basis for the design of the neutral zone of the contact line, and the selection of high-voltage equipment for the EMU.
Open AccessMechanism of Low-Frequency Oscillation When Electric Multiple Units Pass Neutral Zone, and Suppression Method
This article addresses the problem of the contact voltage increase caused by the low-frequency oscillation of the train-grid system in the phase-separation process of EMUs. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and ascertains the relationship between the phase angle when the pantograph leaves the line, and low-frequency oscillations. Methods to suppress overvoltage during the low-frequency oscillation are proposed. The research indicated that a significant voltage amplitude was observed in the neutral zone, when the phase angle of the pantograph to the contact line separation power supply fell within the range of 60–90° and 240–270°. The maximum voltage amplitude reached 69.75 kV, and there was an occurrence of low-frequency oscillation in the neutral zone, where electrical phase separation takes place. During this oscillation, the voltage of the contact network in the neutral zone mainly operated at one-third of the power frequency (16.7 Hz). However, after installing an RC suppression device in the neutral zone, when low-frequency oscillation occurred, the absolute value of the peak voltage dropped below 37 kV as soon as the EMU entered electric phase separation. Furthermore, compared to situations without a connected suppression device, there was nearly a 30% reduction in the absolute value of the peak voltage. The study provides a basis for the design of the neutral zone of the contact line, and the selection of high-voltage equipment for the EMU.
- Open Access
- 19 June 2023
- Published by MDPI AG in Preprints.org
Mechanism of Low Frequency Oscillation When EMUs Passing Neutral Zone and Suppression Method
This article addresses the problem of contact voltage increase caused by the low frequency oscillation of the train-grid system in the phase-separation process of the EMU. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and obtains the relationship between the separation phase angle of the pantograph with line and low-frequency oscillations. Methods to suppress the over-voltage during the low-frequency oscillation are proposed. The study shows that when the power phase angle of the pantograph-line separation is within the range of 60°~90° and 240°~270°, the voltage amplitude in the neutral zone is larger, the maximum amplitude can reach 52.2kV, and low-frequency oscillation will occur in the neutral zone. When low frequency oscillation occurs, the contact line voltage in the neutral zone is mainly 1/3 power frequency (16.7Hz). After installing an RC suppression device in the neutral zone, when the EMU enters the neutral zone, the absolute value of the voltage peak drops to below 20 kV. Compared with the situation where the suppression device is not connected, the absolute value of the voltage peak is reduced by nearly 60%. The study provides a basis for the design of the neutral zone of the contact line and the selection of the high-voltage equipment of the EMU.
- 19 June 2023
- Published by MDPI AG in Preprints.org
Open AccessMechanism of Low Frequency Oscillation When EMUs Passing Neutral Zone and Suppression Method
This article addresses the problem of contact voltage increase caused by the low frequency oscillation of the train-grid system in the phase-separation process of the EMU. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and obtains the relationship between the separation phase angle of the pantograph with line and low-frequency oscillations. Methods to suppress the over-voltage during the low-frequency oscillation are proposed. The study shows that when the power phase angle of the pantograph-line separation is within the range of 60°~90° and 240°~270°, the voltage amplitude in the neutral zone is larger, the maximum amplitude can reach 52.2kV, and low-frequency oscillation will occur in the neutral zone. When low frequency oscillation occurs, the contact line voltage in the neutral zone is mainly 1/3 power frequency (16.7Hz). After installing an RC suppression device in the neutral zone, when the EMU enters the neutral zone, the absolute value of the voltage peak drops to below 20 kV. Compared with the situation where the suppression device is not connected, the absolute value of the voltage peak is reduced by nearly 60%. The study provides a basis for the design of the neutral zone of the contact line and the selection of the high-voltage equipment of the EMU.
- Open Access
The Leakage Current Characteristics of High-Gradient MOA Plate and Its Heating Analysis with Coatings under High-Frequency Overvoltage
High-frequency overvoltage generated in railways results in explosions of Electric Multiple Units’ (EMUs) arrestors. To solve this problem, the leakage current characteristics and heat transfer process of high-gradient MOA plates under high-frequency overvoltage has been studied. The leakage current characteristics of arrestor plates under high-frequency voltage was obtained and the element distribution has been analyzed. Heat transfer distribution and the thermal properties of the Metal Oxide Arrestor (MOA) have been modelled. According to the results, for a given voltage, the higher the harmonic frequency, the greater the leakage current of the arrestor valve plate, and the greater the resistive component of the leakage current. The Zn and O elements in high-gradient MOA plates are more uniform. Under the same leakage current as conventional ones, the undertake voltage of a high-gradient MOA plate will increase by 10%. Longtime high-order harmonic action will still significantly improve the core rod temperature when MOA plates are coated. The temperature rise in the power supply section of EMUs during operation is roughly 35 °C. This result will provide a foundation and supporting data for the applicability of high-gradient valve plates in railroads and coating improvements for traditional arrestor plates.
Open AccessThe Leakage Current Characteristics of High-Gradient MOA Plate and Its Heating Analysis with Coatings under High-Frequency Overvoltage
High-frequency overvoltage generated in railways results in explosions of Electric Multiple Units’ (EMUs) arrestors. To solve this problem, the leakage current characteristics and heat transfer process of high-gradient MOA plates under high-frequency overvoltage has been studied. The leakage current characteristics of arrestor plates under high-frequency voltage was obtained and the element distribution has been analyzed. Heat transfer distribution and the thermal properties of the Metal Oxide Arrestor (MOA) have been modelled. According to the results, for a given voltage, the higher the harmonic frequency, the greater the leakage current of the arrestor valve plate, and the greater the resistive component of the leakage current. The Zn and O elements in high-gradient MOA plates are more uniform. Under the same leakage current as conventional ones, the undertake voltage of a high-gradient MOA plate will increase by 10%. Longtime high-order harmonic action will still significantly improve the core rod temperature when MOA plates are coated. The temperature rise in the power supply section of EMUs during operation is roughly 35 °C. This result will provide a foundation and supporting data for the applicability of high-gradient valve plates in railroads and coating improvements for traditional arrestor plates.
- Open Access
Evolution of Elements on Electrode Surfaces in Gas-Insulated Systems under Electrical Heating
Accidents always occur in gas-insulated switchgears (GIS) and gas-insulated lines (GIL) since filmed joint electrodes are produced when internal gases react with the electrode’s surface when there is a discharge or when internal electricals overheat. To solve the problem, this paper analyzed the evolution of elements on the contact electrode. The reaction of the SF6 and electrode’s surface under breakdown currents and overheating conditions was obtained, and the discharge time and discharge current effects upon the transfer of the element were proposed. It was found that the mobility of the F element on the electrode’s surface typically increases after electrical heating. The number of interruptions and short-circuit currents are important factors affecting the transfer of the F element to the electrode. The flashover current is the essential factor that accelerates the transfer of the F element to insulating materials. Frequent switching is a main factor that accelerates the transfer of the F element to the contact. It was also found that Al has little correlations with the breaking process, and metal fluorides become the main components on the electrode’s surface under discharge heating. The research provides a theoretical basis and data support for GIS/GIL surface optimization treatments and the improvement of fault detection methods.
Open AccessEvolution of Elements on Electrode Surfaces in Gas-Insulated Systems under Electrical Heating
Accidents always occur in gas-insulated switchgears (GIS) and gas-insulated lines (GIL) since filmed joint electrodes are produced when internal gases react with the electrode’s surface when there is a discharge or when internal electricals overheat. To solve the problem, this paper analyzed the evolution of elements on the contact electrode. The reaction of the SF6 and electrode’s surface under breakdown currents and overheating conditions was obtained, and the discharge time and discharge current effects upon the transfer of the element were proposed. It was found that the mobility of the F element on the electrode’s surface typically increases after electrical heating. The number of interruptions and short-circuit currents are important factors affecting the transfer of the F element to the electrode. The flashover current is the essential factor that accelerates the transfer of the F element to insulating materials. Frequent switching is a main factor that accelerates the transfer of the F element to the contact. It was also found that Al has little correlations with the breaking process, and metal fluorides become the main components on the electrode’s surface under discharge heating. The research provides a theoretical basis and data support for GIS/GIL surface optimization treatments and the improvement of fault detection methods.
- Open Access
Modeling and Experimental Analysis of Overvoltage and Inrush Current Characteristics of the Electric Rail Traction Power Supply System
High-speed EMUs (electric multiple-units) frequently pass through the phase-separation zone during operation. Overvoltage generated during the operation of the vehicle-mounted circuit breaker has a long duration and high waveform steepness, which accelerates the service life of the vehicle-mounted equipment and is likely to cause insulation failures. For the above-mentioned problems, the operating overvoltage characteristics of high-speed EMU were obtained by traction substation-catenary-EMUs system (SCES) analysis and experiments, thus deriving the influences of the closed phase angle and the residual magnetism of the vehicle-mounted transformer on operating overvoltage. The results showed that the voltage phase of the catenary significantly affected the operating overvoltage, and the closed switching overvoltage was small at 0–40°, 140–210° and 320–350°. The voltage on the primary side of the vehicle-mounted transformer was 60.78 kV, with the transient impact of high-frequency oscillation overvoltage of 22.71 kV, and an initial period of oscillation of 0.01 ms. Then, the period became longer, and it took 0.5 ms for the high-frequency oscillation from attenuation to disappearance. Finally, a scheme of series reactance suppression devices was proposed to protect vehicle-mounted voltage transformers. This work is to provide data support for the insulation design and system protection of a traction power supply system.
Open AccessModeling and Experimental Analysis of Overvoltage and Inrush Current Characteristics of the Electric Rail Traction Power Supply System
High-speed EMUs (electric multiple-units) frequently pass through the phase-separation zone during operation. Overvoltage generated during the operation of the vehicle-mounted circuit breaker has a long duration and high waveform steepness, which accelerates the service life of the vehicle-mounted equipment and is likely to cause insulation failures. For the above-mentioned problems, the operating overvoltage characteristics of high-speed EMU were obtained by traction substation-catenary-EMUs system (SCES) analysis and experiments, thus deriving the influences of the closed phase angle and the residual magnetism of the vehicle-mounted transformer on operating overvoltage. The results showed that the voltage phase of the catenary significantly affected the operating overvoltage, and the closed switching overvoltage was small at 0–40°, 140–210° and 320–350°. The voltage on the primary side of the vehicle-mounted transformer was 60.78 kV, with the transient impact of high-frequency oscillation overvoltage of 22.71 kV, and an initial period of oscillation of 0.01 ms. Then, the period became longer, and it took 0.5 ms for the high-frequency oscillation from attenuation to disappearance. Finally, a scheme of series reactance suppression devices was proposed to protect vehicle-mounted voltage transformers. This work is to provide data support for the insulation design and system protection of a traction power supply system.