    Mechanism of Low-Frequency Oscillation When Electric Multiple Units Pass Neutral Zone, and Suppression Method

    by Jixing Sun, Kun Zhang, Jiyong Liu, Kaixuan Hu, Jindong Huo, Shengchun Yan, Yan Zhang

    This article addresses the problem of the contact voltage increase caused by the low-frequency oscillation of the train-grid system in the phase-separation process of EMUs. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and ascertains the relationship between the phase angle when the pantograph leaves the line, and low-frequency oscillations. Methods to suppress overvoltage during the low-frequency oscillation are proposed. The research indicated that a significant voltage amplitude was observed in the neutral zone, when the phase angle of the pantograph to the contact line separation power supply fell within the range of 60–90° and 240–270°. The maximum voltage amplitude reached 69.75 kV, and there was an occurrence of low-frequency oscillation in the neutral zone, where electrical phase separation takes place. During this oscillation, the voltage of the contact network in the neutral zone mainly operated at one-third of the power frequency (16.7 Hz). However, after installing an RC suppression device in the neutral zone, when low-frequency oscillation occurred, the absolute value of the peak voltage dropped below 37 kV as soon as the EMU entered electric phase separation. Furthermore, compared to situations without a connected suppression device, there was nearly a 30% reduction in the absolute value of the peak voltage. The study provides a basis for the design of the neutral zone of the contact line, and the selection of high-voltage equipment for the EMU.

  • Open Access

    Mechanism of Low Frequency Oscillation When EMUs Passing Neutral Zone and Suppression Method

    by Jixing Sun, Kun Zhang, Jiyong Liu, Kaixuan Hu, Shengchun Yan, Yan Zhang, Jindong Huo

    This article addresses the problem of contact voltage increase caused by the low frequency oscillation of the train-grid system in the phase-separation process of the EMU. The article establishes the EMU-contact line-traction substation model, reveals the mechanism of low-frequency oscillation, and obtains the relationship between the separation phase angle of the pantograph with line and low-frequency oscillations. Methods to suppress the over-voltage during the low-frequency oscillation are proposed. The study shows that when the power phase angle of the pantograph-line separation is within the range of 60°~90° and 240°~270°, the voltage amplitude in the neutral zone is larger, the maximum amplitude can reach 52.2kV, and low-frequency oscillation will occur in the neutral zone. When low frequency oscillation occurs, the contact line voltage in the neutral zone is mainly 1/3 power frequency (16.7Hz). After installing an RC suppression device in the neutral zone, when the EMU enters the neutral zone, the absolute value of the voltage peak drops to below 20 kV. Compared with the situation where the suppression device is not connected, the absolute value of the voltage peak is reduced by nearly 60%. The study provides a basis for the design of the neutral zone of the contact line and the selection of the high-voltage equipment of the EMU.

  • Open Access

    Evolution of Elements on Electrode Surfaces in Gas-Insulated Systems under Electrical Heating

    by Jixing Sun, Kun Zhang, Kaixuan Hu, Jiyong Liu, Yu Tian, Xin Wang, Shengchun Yan

    Accidents always occur in gas-insulated switchgears (GIS) and gas-insulated lines (GIL) since filmed joint electrodes are produced when internal gases react with the electrode’s surface when there is a discharge or when internal electricals overheat. To solve the problem, this paper analyzed the evolution of elements on the contact electrode. The reaction of the SF6 and electrode’s surface under breakdown currents and overheating conditions was obtained, and the discharge time and discharge current effects upon the transfer of the element were proposed. It was found that the mobility of the F element on the electrode’s surface typically increases after electrical heating. The number of interruptions and short-circuit currents are important factors affecting the transfer of the F element to the electrode. The flashover current is the essential factor that accelerates the transfer of the F element to insulating materials. Frequent switching is a main factor that accelerates the transfer of the F element to the contact. It was also found that Al has little correlations with the breaking process, and metal fluorides become the main components on the electrode’s surface under discharge heating. The research provides a theoretical basis and data support for GIS/GIL surface optimization treatments and the improvement of fault detection methods.


  • Open Access

    Modeling and Experimental Analysis of Overvoltage and Inrush Current Characteristics of the Electric Rail Traction Power Supply System

    by Jixing Sun, Kaixuan Hu, Yongzhi Fan, Jiyong Liu, Shengchun Yan, Yan Zhang

    High-speed EMUs (electric multiple-units) frequently pass through the phase-separation zone during operation. Overvoltage generated during the operation of the vehicle-mounted circuit breaker has a long duration and high waveform steepness, which accelerates the service life of the vehicle-mounted equipment and is likely to cause insulation failures. For the above-mentioned problems, the operating overvoltage characteristics of high-speed EMU were obtained by traction substation-catenary-EMUs system (SCES) analysis and experiments, thus deriving the influences of the closed phase angle and the residual magnetism of the vehicle-mounted transformer on operating overvoltage. The results showed that the voltage phase of the catenary significantly affected the operating overvoltage, and the closed switching overvoltage was small at 0–40°, 140–210° and 320–350°. The voltage on the primary side of the vehicle-mounted transformer was 60.78 kV, with the transient impact of high-frequency oscillation overvoltage of 22.71 kV, and an initial period of oscillation of 0.01 ms. Then, the period became longer, and it took 0.5 ms for the high-frequency oscillation from attenuation to disappearance. Finally, a scheme of series reactance suppression devices was proposed to protect vehicle-mounted voltage transformers. This work is to provide data support for the insulation design and system protection of a traction power supply system.