Optimization of Electrode Configuration for 3-D Brain EIT
Open Access
- 6 May 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-8
Abstract
3-D brain electrical impedance tomography (EIT) holds great promise for real-time noninvasive imaging of various brain injuries. However, a reference method for selecting high-performance electrode configurations has not been proposed. In this article, the optimization of electrode layout, stimulation and measurement protocols, and the number of electrodes are sequentially performed. The signal quality and image reconstruction performance of simulated perturbations in four cortical regions are evaluated with various levels of noise taken into consideration. The results showed that, considering cost and convenience, the best number of electrodes is 20, which should be placed in the suboccipital and central vertex regions as needed. Electrodes with large spacing at different heights are mainly the driving electrodes, and the potential is collected in the appropriate adjacent channels. These principles are expected to provide general guidance for the electrode configuration methods of 3-D brain EIT in clinical applications.Keywords
Funding Information
- Key Research and Development Projects of the Science and Technology Committee (2022YFC2404803)
- Key Basic Research Projects of the Basic Strengthening Plan of the Science and Technology Committee (2019-JCJQ-ZD-115-00-02)
- Xijing Hospital Cross-Fusion Project (XJZT24JC37)
This publication has 42 references indexed in Scilit:
- Protracted neuronal recruitment in the temporal lobes of young childrenNature, 2023
- Animal models for epileptic foci localization, seizure detection, and prediction by electrical impedance tomographyWIREs Cognitive Science, 2022
- Noninvasive Cerebral Imaging and Monitoring Using Electrical Impedance Tomography During Total Aortic Arch ReplacementJournal of Cardiothoracic and Vascular Anesthesia, 2018
- A Robust Current Pattern for the Detection of Intraventricular Hemorrhage in Neonates Using Electrical Impedance TomographyAnnals of Biomedical Engineering, 2010
- An electrode addressing protocol for imaging brain function with electrical impedance tomography using a 16-channel semi-parallel systemPhysiological Measurement, 2009
- A comparison of two EIT systems suitable for imaging impedance changes in epilepsyPhysiological Measurement, 2009
- Electrode configurations for detection of intraventricular haemorrhage in the premature neonatePhysiological Measurement, 2008
- A feasibility study for imaging of epileptic seizures by EIT using a realistic FEM of the head2007
- Electrode placement configurations for 3D EITPhysiological Measurement, 2007
- Three-Dimensional Electrical Impedance Tomography of Human Brain ActivityNeuroImage, 2001