YGYitong Guo

Yitong Guo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yitong Guo has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Xuetao Shi

    Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China

    4 shared publications
  • Mingxu Zhu

    Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China

    3 shared publications
  • Junyao Li

    Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China

    2 shared publications
  • Lei Wang

    Institute of Medical Research, Northwestern Polytechnical University, Xian, China

    2 shared publications
  • Lijun Yuan

    Department of Ultrasound Diagnostics, Tangdu Hospital, Fourth Military Medical University, Xi’an, China

    2 shared publications
  • Ruteng Song

    Department of Biomedical Engineering, Shaanxi Provincial Key Laboratory of Bioelectromagnetic Deterction and Intelligent Perception, Air Force Medical University, Xi’an, China

    2 shared publications

Latest Publications

  • Noninvasive Electrical Impedance Tomography for the Monitoring and the Quantification of Tissue Temperature During Liver Cancer Hyperthermia

    by Yitong Guo, Shujia Peng, Junyao Li, Ruteng Song, Mingxu Zhu, Wenjing Zhu, Yu Wang, Qiang Ma, Zhenyu Ji, Xuetao Shi

    Accurate non-invasive temperature monitoring during liver tumor hyperthermia remains a significant clinical challenge. This study evaluates the use of electrical impedance tomography (EIT) for quantitative temperature mapping in hepatic thermal therapy by incorporating tissue-specific electrophysiological properties. Based on prior characterization of temperature-dependent electrical conductivity (30–90°C, 1 Hz–1 MHz) in murine hepatocellular carcinoma (HCC) models, computational simulations were developed to demonstrate EIT reconstructed value-temperature correlations. In vivo validation was conducted using orthotopic HCC mice subjected to infrared laser heating (n=6) and radiofrequency ablation (RFA) (n=4), with thermal changes monitored via a custom 16-electrode EIT system operating at 10 kHz. A novel 3D-printed scaffold ensured stable electrode placement on the abdominal surface. Region-of-interest analysis defined tumor, heat affected liver, and distal liver zones. Results revealed strong linear correlations (R²=0.88– 0.93, p<0.0001) between EIT-reconstructed values and thermocouple measured temperatures through tissue-specific temperature-dependent impedance functions. EIT accurately localized thermal lesions and visualized the spatiotemporal evolution of temperature during ablation, with quantification errors of ≤2.8°C (tumor tissue), ≤3.6°C (heated liver tissue), and ≤4.5°C (distal liver tissue), as histologically confirmed. We believe that the technology holds significant potential for improving treatment efficacy in HCC hyperthermia protocols through non-invasive temperature quantification.


  • Open Access

    Dynamic Cerebral Perfusion Electrical Impedance Tomography: A Neuroimaging Technique for Bedside Cerebral Perfusion Monitoring During Mannitol Dehydration

    by Weice Wang, Lihua Hou, Canhua Xu, Mingxu Zhu, Yitong Guo, Rong Zhao, Weixun Duan, Yu Wang, Zhenxiao Jin, Xuetao Shi

    Mannitol dehydration is routinely used to prevent and treat cerebral damage after total aortic arch replacement (TAAR), but existing neuroimaging technologies cannot achieve bedside real-time quantitative assessment of its impact on cerebral perfusion in different patients. This study applied dynamic cerebral perfusion electrical impedance tomography (DCP-EIT), a non-invasive neuroimaging technique, for bedside cerebral perfusion monitoring in TAAR patients during dehydration. Seventeen patients with normal neurological function and nineteen with neurological dysfunction (ND) were enrolled. The variation patterns and differences in perfusion impedance, images, and the relative ratios (RY) of mean perfusion velocity (MV), height of systolic wave (Hs), inflow volume velocity (IV), and angle between the ascending branch and baseline (Aab) were analyzed. Results showed DCP-EIT could visualize cerebral perfusion changes, with detected poorly perfused regions showing good consistency with ischemic areas identified by computed tomography (CT). RY of normal patients fluctuated around 0.97–1.04, with no significant difference from baseline. RY of ND patients peaked at 14–20 min after dehydration and remained higher than baseline even at 100 min (p < 0.001). DCP-EIT holds potential to optimize individualized cerebral protection strategies for other cerebral damage scenarios and neurocritical care.


  • Open Access

    In vivo electrical properties of the healthy liver and the hepatic tumor in a mouse model between 1 Hz and 1 MHz during a thermal treatment

    by Yitong Guo, Weice Wang, Weichen Li, Junyao Li, Mingxu Zhu, Ruteng Song, Wenjing Zhu, Lei Wang, Zhenyu Ji, Xuetao Shi

    Objective: Understansding the changing patterns of in vivo electrical properties for the target tissue is crucial for the accurate temperature monitoring and the treatment efficacy in thermal therapy. Our research aims to investigate the changing patterns and the reversibility of in vivo electrical properties for both healthy livers and liver tumors in a mouse model over a frequency range of 1 Hz to 1 MHz at temperatures between 30 °C to 90 °C. Methods and materials: The mice were anesthetized and the target organ was exposed. An 808-nm near-infrared laser was employed as the heating source to heat the organ in vivo. The four-needle electrode, connected to an impedance analyzer, was utilized to obtain the impedance at varying temperatures, which were monitored by a thermocouple. Results: The findings indicated a gradual decline in impedance with an increase in temperature. Furthermore, the impedance was normalized to that at 30 °C, and the real part of the normalized impedance was defined as the k-values, which range from 0 to 1. The results demonstrated a linear correlation between k-values and temperatures (R2 > 0.9 for livers and R2 > 0.8 for tumors). Significant differences were observed between livers and tumors at 1, 10 and 50 kHz (p < 0.05). Additionally, it was demonstrated that the electrical properties could be reversed when the temperature was below or equal to 45 °C. Conclusion: We believe that these results will contribute to the advancement of radiofrequency ablation systems and the development of techniques for temperature monitoring during liver thermal treatment.


  • Open Access

    Optimization of Electrode Configuration for 3-D Brain EIT

    by Siyuan Bai, Yitong Guo, Weichen Li, Lei Wang, Xuetao Shi

    3-D brain electrical impedance tomography (EIT) holds great promise for real-time noninvasive imaging of various brain injuries. However, a reference method for selecting high-performance electrode configurations has not been proposed. In this article, the optimization of electrode layout, stimulation and measurement protocols, and the number of electrodes are sequentially performed. The signal quality and image reconstruction performance of simulated perturbations in four cortical regions are evaluated with various levels of noise taken into consideration. The results showed that, considering cost and convenience, the best number of electrodes is 20, which should be placed in the suboccipital and central vertex regions as needed. Electrodes with large spacing at different heights are mainly the driving electrodes, and the potential is collected in the appropriate adjacent channels. These principles are expected to provide general guidance for the electrode configuration methods of 3-D brain EIT in clinical applications.


  • Open Access

    Ultrasound triggered topical delivery of Bmp7 mRNA for white fat browning induction via engineered smart exosomes

    by Yitong Guo, Zhuo Wan, Ping Zhao, Mengying Wei, Yunnan Liu, Te Bu, Wenqi Sun, Zhelong Li, Lijun Yuan

    Background: Efficient and topical delivery of drugs is essential for maximized efficacy and minimized toxicity. In this study, we aimed to design an exosome-based drug delivery platform endowed with the ability of escaping from phagocytosis at non-target organs and controllably releasing drugs at targeted location. Results: The swtichable stealth coat CP05-TK-mPEG was synthesized and anchored onto exosomes through the interaction between peptide CP05 and exosomal surface marker CD63. Chlorin e6 (Ce6) was loaded into exosomes by direct incubation. Controllable removal of PEG could be achieved by breaking thioketal (TK) through reactive oxygen species (ROS), which was produced by Ce6 under ultrasound irradiation. The whole platform was called SmartExo. The stealth effects were analyzed in RAW264.7 cells and C57BL/6 mice via tracing the exosomes. To confirm the efficacy of the engineered smart exosomes, Bone morphogenetic protein 7 (Bmp7) mRNA was encapsulated into exosomes by transfection of overexpressing plasmid, followed by stealth coating, with the exosomes designated as SmartExo@Bmp7. Therapeutic advantages of SmartExo@Bmp7 were proved by targeted delivering Bmp7 mRNA to omental adipose tissue (OAT) of obese C57BL/6 mice for browning induction. SmartExo platform was successfully constructed without changing the basic characteristics of exosomes. The engineered exosomes effectively escaped from the phagocytosis by RAW264.7 and non-target organs. In addition, the SmartExo could be uptaken locally on-demand by ultrasound mediated removal of the stealth coat. Compared with control exosomes, SmartExo@Bmp7 effectively delivered Bmp7 mRNA into OAT upon ultrasound irradiation, and induced OAT browning, as evidenced by the histology of OAT and increased expression of uncoupling protein 1 (Ucp1). Conclusions: The proposed SmartExo-based delivery platform, which minimizes side effects and maximizing drug efficacy, offers a novel safe and efficient approach for targeted drug delivery. As a proof, the SmartExo@Bmp7 induced local white adipose tissue browning, and it would be a promising strategy for anti-obesity therapy. Graphical


  • Three‐dimensional printed multicolor normal and abnormal fetal hearts based on ultrasound imaging data

    by Yi‐Tong Guo, N. Hou, Jia‐He Liang, Ze‐Kai Zhang, Tie‐Sheng Cao, Li‐Jun Yuan