Siyuan Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Siyuan Bai has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Lei Wang
Institute of Medical Research, Northwestern Polytechnical University, Xian, China
1 shared publication - Weichen Li
Department of Radiology, Functional and Molecular Imaging Key Laboratory of Shaanxi Province, Tangdu Hospital, Air Force Medical University, Xian, China
1 shared publication - Xuetao Shi
Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
1 shared publication - Yitong Guo
Department of Ultrasound Diagnosis, 3D Printing Research Center, Tangdu Hospital, Air Force Medical University, Xian, China
1 shared publication
Latest Publications
- Open Access
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-8
Optimization of Electrode Configuration for 3-D Brain EIT
3-D brain electrical impedance tomography (EIT) holds great promise for real-time noninvasive imaging of various brain injuries. However, a reference method for selecting high-performance electrode configurations has not been proposed. In this article, the optimization of electrode layout, stimulation and measurement protocols, and the number of electrodes are sequentially performed. The signal quality and image reconstruction performance of simulated perturbations in four cortical regions are evaluated with various levels of noise taken into consideration. The results showed that, considering cost and convenience, the best number of electrodes is 20, which should be placed in the suboccipital and central vertex regions as needed. Electrodes with large spacing at different heights are mainly the driving electrodes, and the potential is collected in the appropriate adjacent channels. These principles are expected to provide general guidance for the electrode configuration methods of 3-D brain EIT in clinical applications.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 3, 1-8
Open AccessOptimization of Electrode Configuration for 3-D Brain EIT
3-D brain electrical impedance tomography (EIT) holds great promise for real-time noninvasive imaging of various brain injuries. However, a reference method for selecting high-performance electrode configurations has not been proposed. In this article, the optimization of electrode layout, stimulation and measurement protocols, and the number of electrodes are sequentially performed. The signal quality and image reconstruction performance of simulated perturbations in four cortical regions are evaluated with various levels of noise taken into consideration. The results showed that, considering cost and convenience, the best number of electrodes is 20, which should be placed in the suboccipital and central vertex regions as needed. Electrodes with large spacing at different heights are mainly the driving electrodes, and the potential is collected in the appropriate adjacent channels. These principles are expected to provide general guidance for the electrode configuration methods of 3-D brain EIT in clinical applications.