Comparison of Different Modes in Optical Coherence Tomography and Ultrasound Biomicroscopy in Anterior Chamber Angle Assessment
Authors:
- Melike PekmezciMPMelike Pekmezci
- Ryan P. BashamRBRyan P. Basham
- Mingguang HeMHMingguang He
- Michael I. SeiderMSMichael I. Seider
- Shan C. LinSLShan C. Lin
- 1 August 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 18 (6) , 472-478
Abstract
To compare anterior chamber angle width measurements by low and high-resolution anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). Thirty-six eyes of 32 patients with gonioscopically narrow angles from a university-based glaucoma clinic were recruited in the study. All subjects received AS-OCT {in “Anterior Segment Single” mode [low-resolution optical coherence tomography (LOCT)] and “High-resolution Cornea” mode [high-resolution optical coherence tomography (HOCT)]} and UBM examination in 1 or both eyes. Angle opening distance (AOD) and angle recess area of temporal (t) and nasal (n) quadrants were assessed using the customized software on each type of image. Angle measurements from UBM, LOCT, and HOCT images were compared; intraobserver and interobserver measurement reproducibility for each type of image was also evaluated. Thirty-three eyes of 29 patients were available for analysis. No significant differences were found between LOCT and UBM in the measurement of t-AOD (P=0.350), n-AOD (P=0.106), and n-angle recess area (P=0.360). HOCT measurements were significantly larger than both LOCT and UBM for all parameters (all, P<0.05). HOCT images had better interobserver and intraobserver measurement reproducibility than UBM images. LOCT is similar to UBM for most of the studied angle measurements. HOCT tends to give larger measurements than both LOCT and UBM. AS-OCT measurements were more reproducible than those from UBM.Keywords
This publication has 19 references indexed in Scilit:
- Imaging the Ocular Anterior Segment With Real-Time, Full-Range Fourier-Domain Optical Coherence TomographyArchives of Ophthalmology (1950), 2008
- Anterior segment imaging for glaucoma: OCT or UBM?British Journal of Ophthalmology, 2007
- Reproducibility of Anterior Chamber Angle Measurements Obtained with Anterior Segment Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2007
- Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomographyBritish Journal of Ophthalmology, 2007
- Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segmentJournal of Cataract & Refractive Surgery, 2007
- Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?British Journal of Ophthalmology, 2007
- Advances in anterior segment imagingCurrent Opinion in Ophthalmology, 2007
- Anterior chamber width measurement by high-speed optical coherence tomographyOphthalmology, 2005
- Refractive correction method for digital charge-coupled device-recorded Scheimpflug photographs by means of ray tracingJournal of Biomedical Optics, 2005
- Optical coherence tomography of the anterior segment of the eyeOphthalmology Clinics of North America, 2004