Masaya Tamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Masaya Tamura has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
A Shibuya
1 shared publicationAkitaka Nonomura
Department of Clinical Pathology, Kanazawa University School of Medicine, 13-1 Takaramachi, Kanazawa 920-8640, Japan
1 shared publication- Alexander Evgenyevich Berezin
Department of Internal Medicine II, Division of Cardiology, Paracelsus Medical University Salzburg, Salzburg, Austria
1 shared publication - Ehsan Abadi
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
1 shared publication - Ehsan Samei
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
1 shared publication - Go Watanabe
Department of Data Science, School of Frontier Engineering, Kitasato University, 1-15-1 Kitazato, Minami-ku, Sagamihara, Kanagawa, Japan, 252-0373
1 shared publication
Latest Publications
- Open Access
- 2 March 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1616-1623
Assessment of pleural invasion and adhesion of lung tumors with dynamic chest radiography: A virtual clinical imaging study
Purpose: Accurate preoperative assessment of tumor invasion/adhesion is crucial for planning appropriate operative procedures. Recent advances in digital radiography allow a motion analysis of lung tumors with dynamic chest radiography (DCR) with total exposure dose comparable to that of conventional chest radiography. The aim of this study was to investigate the feasibility of preoperative evaluation of pleural invasion/adhesion of lung tumors with DCR through a virtual clinical imaging study, using a four‐dimensional (4D) extended cardiac‐torso (XCAT) computational phantom.Methods: An XCAT phantom of an adult man (50th percentile in height and weight) with simulated respiratory and cardiac motions was generated to use as a virtual patient. To simulate lung tumors with and without pleural invasion, a 30‐mm diameter tumor sphere was inserted into each lobe of the phantom. The virtual patient during respiration was virtually projected using an x‐ray simulator in posteroanterior (PA) and oblique directions, and sequential bone suppression (BS) images were created. The measurement points (tumor, rib, and diaphragm) were automatically tracked on simulated images by a template matching technique. We calculated five quantitative metrics related to the movement distance and directions of the targeted tumor and evaluated whether DCR could distinguish between tumors with and without pleural invasion/adhesion.Results: Precise tracking of the targeted tumor was achieved on the simulated BS images without undue influence of rib shadows. There was a significant difference in all five quantitative metrics between the lung tumors with and without pleural invasion both on the oblique and PA projection views (P < 0.05). Quantitative metrics related to the movement distance were effective for tumors in the middle and lower lobes, while, those related to the movement directions were effective for tumors close to the frontal chest wall on the oblique projection view. The oblique views were useful for the evaluation of the space between the chest wall and a moving tumor.Conclusion: DCR could help distinguish between tumors with and without pleural invasion/adhesion based on the two‐dimensional movement distance and direction using oblique and PA projection views. With anticipated improved image: processing to evaluate the respiratory displacement of lung tumors in the upper lobe or behind the heart, DCR holds promise for clinical assessment of tumor invasion/adhesion in the parietal pleura.
- 2 March 2021
- Published by Wiley in Medical Physics
- Vol. 48 (4) , 1616-1623
Open AccessAssessment of pleural invasion and adhesion of lung tumors with dynamic chest radiography: A virtual clinical imaging study
Purpose: Accurate preoperative assessment of tumor invasion/adhesion is crucial for planning appropriate operative procedures. Recent advances in digital radiography allow a motion analysis of lung tumors with dynamic chest radiography (DCR) with total exposure dose comparable to that of conventional chest radiography. The aim of this study was to investigate the feasibility of preoperative evaluation of pleural invasion/adhesion of lung tumors with DCR through a virtual clinical imaging study, using a four‐dimensional (4D) extended cardiac‐torso (XCAT) computational phantom.Methods: An XCAT phantom of an adult man (50th percentile in height and weight) with simulated respiratory and cardiac motions was generated to use as a virtual patient. To simulate lung tumors with and without pleural invasion, a 30‐mm diameter tumor sphere was inserted into each lobe of the phantom. The virtual patient during respiration was virtually projected using an x‐ray simulator in posteroanterior (PA) and oblique directions, and sequential bone suppression (BS) images were created. The measurement points (tumor, rib, and diaphragm) were automatically tracked on simulated images by a template matching technique. We calculated five quantitative metrics related to the movement distance and directions of the targeted tumor and evaluated whether DCR could distinguish between tumors with and without pleural invasion/adhesion.Results: Precise tracking of the targeted tumor was achieved on the simulated BS images without undue influence of rib shadows. There was a significant difference in all five quantitative metrics between the lung tumors with and without pleural invasion both on the oblique and PA projection views (P < 0.05). Quantitative metrics related to the movement distance were effective for tumors in the middle and lower lobes, while, those related to the movement directions were effective for tumors close to the frontal chest wall on the oblique projection view. The oblique views were useful for the evaluation of the space between the chest wall and a moving tumor.Conclusion: DCR could help distinguish between tumors with and without pleural invasion/adhesion based on the two‐dimensional movement distance and direction using oblique and PA projection views. With anticipated improved image: processing to evaluate the respiratory displacement of lung tumors in the upper lobe or behind the heart, DCR holds promise for clinical assessment of tumor invasion/adhesion in the parietal pleura.
- Open Access
- 5 November 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (12) , 10-19
Quantitative analysis of treatments using real‐time image gated spot‐scanning with synchrotron‐based proton beam therapy system log data
A synchrotron‐based real‐time image gated spot‐scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra‐field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron‐based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron‐based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra‐field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron‐based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra‐field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.
- 5 November 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (12) , 10-19
Open AccessQuantitative analysis of treatments using real‐time image gated spot‐scanning with synchrotron‐based proton beam therapy system log data
A synchrotron‐based real‐time image gated spot‐scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra‐field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron‐based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron‐based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra‐field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron‐based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra‐field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.
- 1 January 2002
- Published by Springer Nature in Surgery Today
- Vol. 32 (1) , 69-71
Small Intestinal Bleeding Secondary to Metastatic Malignant Fibrous Histiocytoma of the Rib: Report of a Case
Malignant fibrous histiocytoma (MFH) is an aggressive bone tumor with a high propensity for metastasis. We describe herein the case of a 73-year-old man found to have MFH of the rib with a metastasis in the small intestine. The patient complained of gastrointestinal bleeding as the first symptom. Computed tomography imaging demonstrated a tumor in the left chest wall, and abdominal magnetic resonance imaging revealed thickening of the wall in the internal cavity of the small intestine. Histopathological and immunohistochemical examination confirmed that the tumor in the small intestine was an MFH that had metastasized from the rib.
- 1 January 2002
- Published by Springer Nature in Surgery Today
- Vol. 32 (1) , 69-71
Small Intestinal Bleeding Secondary to Metastatic Malignant Fibrous Histiocytoma of the Rib: Report of a Case
Malignant fibrous histiocytoma (MFH) is an aggressive bone tumor with a high propensity for metastasis. We describe herein the case of a 73-year-old man found to have MFH of the rib with a metastasis in the small intestine. The patient complained of gastrointestinal bleeding as the first symptom. Computed tomography imaging demonstrated a tumor in the left chest wall, and abdominal magnetic resonance imaging revealed thickening of the wall in the internal cavity of the small intestine. Histopathological and immunohistochemical examination confirmed that the tumor in the small intestine was an MFH that had metastasized from the rib.
- 1 September 1995
- Published by Elsevier in Journal of Aerosol Science
- Vol. 26, S585-S586
Generation of aerosol particles during the destruction of xylene, and trichloroethylene from air stream by a pulse corona discharge
- 1 September 1995
- Published by Elsevier in Journal of Aerosol Science
- Vol. 26, S585-S586
Generation of aerosol particles during the destruction of xylene, and trichloroethylene from air stream by a pulse corona discharge