Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Open Access
- 12 December 2019
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 11 (12) , e6364
Abstract
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (Dmax: 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord Dmax: 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) Dmax: 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.Keywords
This publication has 30 references indexed in Scilit:
- Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a 60 Co Magnetic Resonance Image Guidance Radiation Therapy SystemInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Benchmark IMRT evaluation of a Co-60 MRI-guided radiation therapy systemRadiotherapy and Oncology, 2015
- Patient-Specific Quality Assurance for the Delivery of 60Co Intensity Modulated Radiation Therapy Subject to a 0.35-T Lateral Magnetic FieldInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- The Magnetic Resonance Imaging–Linac SystemSeminars in Radiation Oncology, 2014
- The ViewRay System: Magnetic Resonance–Guided and Controlled RadiotherapySeminars in Radiation Oncology, 2014
- International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic RadiosurgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Stereotactic body radiation therapy: The report of AAPM Task Group 101Medical Physics, 2010
- Comparative analysis of60Co intensity-modulated radiation therapyPhysics in Medicine & Biology, 2008
- Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal LesionsNeurosurgery, 2001
- Preliminary Clinical Experience with Linear Accelerator-based Spinal Stereotactic RadiosurgeryNeurosurgery, 1995