Martha Malin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martha Malin has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Larry A. DeWerd
Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, Madison, Wisconsin 53705, USA
3 shared publicationsHania Al-Hallaq
Department of Radiation and Cellular Oncology, University of Chicago Medical Center, Chicago, USA
2 shared publicationsL DeWerd
2 shared publicationsYasmin Hasan
Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, IL, USA
2 shared publicationsA. McCarthy
NYU Langone Hlth, Dept Radiat Oncol, New York, NY USA
1 shared publicationAllison McCarthy
Department of Radiation Oncology Laura and Isaac Perlmutter Cancer Center NYU Langone Health New York NY USA
1 shared publication
Latest Publications
- Open Access
- 23 September 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (10) , 122-131
Full automation of spinal stereotactic radiosurgery and stereotactic body radiation therapy treatment planning using Varian Eclipse scripting
The purpose of this feasibility study is to develop a fully automated procedure capable of generating treatment plans with multiple fractionation schemes to improve speed, robustness, and standardization of plan quality. A fully automated script was implemented for spinal stereotactic radiosurgery/stereotactic body radiation therapy (SRS/SBRT) plan generation using Eclipse v15.6 API. The script interface allows multiple dose/fractionation plan requests, planning target volume (PTV) expansions, as well as information regarding distance/overlap between spinal cord and targets to drive decision‐making. For each requested plan, the script creates the course, plans, field arrangements, and automatically optimizes and calculates dose. The script was retrospectively applied to ten computed tomography (CT) scans of previous cervical, thoracic, and lumbar spine SBRT patients. Three plans were generated for each patient — simultaneous integrated boost (SIB) 1800/1600 cGy to gross tumor volume (GTV)/PTV in one fraction; SIB 2700/2100 cGy to GTV/PTV in three fractions; and 3000 cGy to PTV in five fractions. Plan complexity and deliverability patient‐specific quality assurance (QA) was performed using ArcCHECK with an Exradin A16 chamber inserted. Dose objectives were met for all organs at risk (OARs) for each treatment plan. Median target coverage was GTV V100% = 87.3%, clinical target volume (CTV) V100% = 95.7% and PTV V100% = 88.0% for single fraction plans; GTV V100% = 95.6, CTV V100% = 99.6% and PTV V100% = 97.2% for three fraction plans; and GTV V100% = 99.6%, CTV V100% = 99.1% and PTV V100% = 97.2% for five fraction plans. All plans (n = 30) passed patient‐specific QA (>90%) at 2%/2 mm global gamma. A16 chamber dose measured at isocenter agreed with planned dose within 3% for all cases. Automatic planning for spine SRS/SBRT through scripting increases efficiency, standardizes plan quality and approach, and provides a tool for target coverage comparison of different fractionation schemes without the need for additional resources.
- 23 September 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (10) , 122-131
Open AccessFull automation of spinal stereotactic radiosurgery and stereotactic body radiation therapy treatment planning using Varian Eclipse scripting
The purpose of this feasibility study is to develop a fully automated procedure capable of generating treatment plans with multiple fractionation schemes to improve speed, robustness, and standardization of plan quality. A fully automated script was implemented for spinal stereotactic radiosurgery/stereotactic body radiation therapy (SRS/SBRT) plan generation using Eclipse v15.6 API. The script interface allows multiple dose/fractionation plan requests, planning target volume (PTV) expansions, as well as information regarding distance/overlap between spinal cord and targets to drive decision‐making. For each requested plan, the script creates the course, plans, field arrangements, and automatically optimizes and calculates dose. The script was retrospectively applied to ten computed tomography (CT) scans of previous cervical, thoracic, and lumbar spine SBRT patients. Three plans were generated for each patient — simultaneous integrated boost (SIB) 1800/1600 cGy to gross tumor volume (GTV)/PTV in one fraction; SIB 2700/2100 cGy to GTV/PTV in three fractions; and 3000 cGy to PTV in five fractions. Plan complexity and deliverability patient‐specific quality assurance (QA) was performed using ArcCHECK with an Exradin A16 chamber inserted. Dose objectives were met for all organs at risk (OARs) for each treatment plan. Median target coverage was GTV V100% = 87.3%, clinical target volume (CTV) V100% = 95.7% and PTV V100% = 88.0% for single fraction plans; GTV V100% = 95.6, CTV V100% = 99.6% and PTV V100% = 97.2% for three fraction plans; and GTV V100% = 99.6%, CTV V100% = 99.1% and PTV V100% = 97.2% for five fraction plans. All plans (n = 30) passed patient‐specific QA (>90%) at 2%/2 mm global gamma. A16 chamber dose measured at isocenter agreed with planned dose within 3% for all cases. Automatic planning for spine SRS/SBRT through scripting increases efficiency, standardizes plan quality and approach, and provides a tool for target coverage comparison of different fractionation schemes without the need for additional resources.
- 1 March 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (5) , 05NT01
A practical method for quantifying dose in bone and lung using TLDs when using 6 and 15 MV photon beams
This paper presents a practical method for converting dose measured with thermoluminescent dosimeters (TLD) to dose in lung and bone for 6 MV and 15 MV photon beams. Monte Carlo (MC) simulations and Burlin cavity theory calculations were performed to calculate , the dose-to-TLD to dose-to-medium conversion factor. A practical method was proposed for converting TLD-measured-dose to dose-in-medium using the TLD dose calibration in water and dose-to-medium to dose-to-water conversion factor. Theoretical calculations for were performed using photon spectrum weighted parameters and were compared with MC simulations. Verification of the proposed method was done using phantoms having either bone or lung equivalent slabs stacked in between solid water slabs. Percent depth dose (PDD) curves were measured using 0.089 cm thick LiF:Mg,Ti (TLD-100) dosemeters placed at various depths within these phantoms. They were then corrected with factors using the proposed dose conversion method, and were compared with the MC simulations. For 6 MV beam, the MC calculated factors were 0.942 and 1.002 for bone and lung, and for 15 MV it was 0.927 and 1.005 for bone and lung, respectively. The difference between the MC simulated and spectrum weighted theoretical factors were within 3% for both lung and bone. The PDD curves measured with TLD-100 chips that were corrected using the proposed method agreed well within 1.5% of the MC simulated PDD curves for both the water/lung/water and water/bone/water (WBW) phantoms. The dose-to-medium correction using MC simulated is convenient, easy, and accurate. Therefore, it can be used instead of Burlin cavity theory, especially in media with high atomic numbers such as bone for accurate dose quantification.
- 1 March 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (5) , 05NT01
A practical method for quantifying dose in bone and lung using TLDs when using 6 and 15 MV photon beams
This paper presents a practical method for converting dose measured with thermoluminescent dosimeters (TLD) to dose in lung and bone for 6 MV and 15 MV photon beams. Monte Carlo (MC) simulations and Burlin cavity theory calculations were performed to calculate , the dose-to-TLD to dose-to-medium conversion factor. A practical method was proposed for converting TLD-measured-dose to dose-in-medium using the TLD dose calibration in water and dose-to-medium to dose-to-water conversion factor. Theoretical calculations for were performed using photon spectrum weighted parameters and were compared with MC simulations. Verification of the proposed method was done using phantoms having either bone or lung equivalent slabs stacked in between solid water slabs. Percent depth dose (PDD) curves were measured using 0.089 cm thick LiF:Mg,Ti (TLD-100) dosemeters placed at various depths within these phantoms. They were then corrected with factors using the proposed dose conversion method, and were compared with the MC simulations. For 6 MV beam, the MC calculated factors were 0.942 and 1.002 for bone and lung, and for 15 MV it was 0.927 and 1.005 for bone and lung, respectively. The difference between the MC simulated and spectrum weighted theoretical factors were within 3% for both lung and bone. The PDD curves measured with TLD-100 chips that were corrected using the proposed method agreed well within 1.5% of the MC simulated PDD curves for both the water/lung/water and water/bone/water (WBW) phantoms. The dose-to-medium correction using MC simulated is convenient, easy, and accurate. Therefore, it can be used instead of Burlin cavity theory, especially in media with high atomic numbers such as bone for accurate dose quantification.
- Open Access
- 12 December 2019
- Published by Springer Nature in Cureus
- Vol. 11 (12) , e6364
Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (Dmax: 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord Dmax: 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) Dmax: 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.
- 12 December 2019
- Published by Springer Nature in Cureus
- Vol. 11 (12) , e6364
Open AccessDosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (Dmax: 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord Dmax: 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) Dmax: 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.
- 1 September 2019
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 105 (1) , E788-E789
Robust VMAT-based Total Body Irradiation (TBI) Treatment Planning Assisted by Eclipse Scripting
- 1 September 2019
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 105 (1) , E788-E789
Robust VMAT-based Total Body Irradiation (TBI) Treatment Planning Assisted by Eclipse Scripting
- Open Access
- 22 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (4) , 205-213
Single‐institution report of setup margins of voluntary deep‐inspiration breath‐hold (DIBH) whole breast radiotherapy implemented with real‐time surface imaging
Purpose: We calculated setup margins for whole breast radiotherapy during voluntary deep‐inspiration breath‐hold (vDIBH) using real‐time surface imaging (SI).Methods and Materials: Patients (n = 58) with a 27‐to‐31 split between right‐ and left‐sided cancers were analyzed. Treatment beams were gated using AlignRT by registering the whole breast region‐of‐interest to the surface generated from the simulation CT scan. AlignRT recorded (three‐dimensional) 3D displacements and the beam‐on‐state every 0.3 s. Means and standard deviations of the displacements during vDIBH for each fraction were used to calculate setup margins. Intra‐DIBH stability and the intrafraction reproducibility were estimated from the medians of the 5th to 95th percentile range of the translations in each breath‐hold and fraction, respectively.Results: A total of 7269 breath‐holds were detected over 1305 fractions in which a median dose of 200 cGy was delivered. Each fraction was monitored for 5.95 ± 2.44 min. Calculated setup margins were 4.8 mm (A/P), 4.9 mm (S/I), and 6.4 mm (L/R). The intra‐DIBH stability and the intrafraction reproducibility were ≤0.7 mm and ≤2.2 mm, respectively. The isotropic margin according to SI (9.2 mm) was comparable to other institutions’ calculations that relied on x‐ray imaging and/or spirometry for patients with left‐sided cancer (9.8–11.0 mm). Likewise, intra‐DIBH variability and intrafraction reproducibility of breast surface measured with SI agreed with spirometry‐based positioning to within 1.2 and 0.36 mm, respectively.Conclusions: We demonstrated that intra‐DIBH variability, intrafraction reproducibility, and setup margins are similar to those reported by peer studies who utilized spirometry‐based positioning.
- 22 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (4) , 205-213
Open AccessSingle‐institution report of setup margins of voluntary deep‐inspiration breath‐hold (DIBH) whole breast radiotherapy implemented with real‐time surface imaging
Purpose: We calculated setup margins for whole breast radiotherapy during voluntary deep‐inspiration breath‐hold (vDIBH) using real‐time surface imaging (SI).Methods and Materials: Patients (n = 58) with a 27‐to‐31 split between right‐ and left‐sided cancers were analyzed. Treatment beams were gated using AlignRT by registering the whole breast region‐of‐interest to the surface generated from the simulation CT scan. AlignRT recorded (three‐dimensional) 3D displacements and the beam‐on‐state every 0.3 s. Means and standard deviations of the displacements during vDIBH for each fraction were used to calculate setup margins. Intra‐DIBH stability and the intrafraction reproducibility were estimated from the medians of the 5th to 95th percentile range of the translations in each breath‐hold and fraction, respectively.Results: A total of 7269 breath‐holds were detected over 1305 fractions in which a median dose of 200 cGy was delivered. Each fraction was monitored for 5.95 ± 2.44 min. Calculated setup margins were 4.8 mm (A/P), 4.9 mm (S/I), and 6.4 mm (L/R). The intra‐DIBH stability and the intrafraction reproducibility were ≤0.7 mm and ≤2.2 mm, respectively. The isotropic margin according to SI (9.2 mm) was comparable to other institutions’ calculations that relied on x‐ray imaging and/or spirometry for patients with left‐sided cancer (9.8–11.0 mm). Likewise, intra‐DIBH variability and intrafraction reproducibility of breast surface measured with SI agreed with spirometry‐based positioning to within 1.2 and 0.36 mm, respectively.Conclusions: We demonstrated that intra‐DIBH variability, intrafraction reproducibility, and setup margins are similar to those reported by peer studies who utilized spirometry‐based positioning.
- Open Access
- 1 January 2018
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 10 (3) , 218-224
Initial experience using superflab as intravaginal packing during interstitial brachytherapy for advanced gynecologic cancer
Purpose: Interstitial brachytherapy implemented for locally advanced gynecologic cancer can result in toxicity due to the proximity of organs at risk (OAR). We report our experience using superflab bolus as vaginal packing to displace OAR during interstitial brachytherapy. Material and methods: Twelve patients with stage IB-IVA gynecologic cancer were treated with definitive chemoradiation including interstitial brachytherapy. A Syed template was used for a computed tomography (CT)-based preplan with magnetic resonance imaging (MRI) fusion. A 1-2 cm superflab bolus was cut and sterilized. The tandem and obturator were placed, and superflab was then inserted into the vagina. Interstitial needles were then placed through the template and superflab as per the pre-plan under transabdominal ultrasound guidance. Prescription doses ranged from 85-90 Gy EQD(2) including external beam radiation therapy (EBRT). 5-6 Gy per fraction was delivered biologically effective dose (BID) over 2-3 days in 1-2 implants. Toxicities were evaluated post-treatment, 1 month, and 3 months. Results: The rectum, bladder, and sigmoid had significant average displacement from the prescription isodose line. The average reduction in D-2cc between pre- and post-implant was 5.19 Gy per fraction (p < 0.0001), 7.19 Gy (p < 0.0004), and 1.78 Gy (p < 0.003) for the rectum, bladder, and sigmoid, respectively. The high-risk target volume (HR-TV) received a median D-90 of 104% (range, 58-122%) of the prescription dose, and 92% (range, 71-131%) in the pre-/post-implant plans, respectively (p = 0.4). Conclusions: Our initial experience with superflab as vaginal packing demonstrates technical feasibility and dosimetric improvement for OAR.
- 1 January 2018
- Published by Termedia Sp. z.o.o. in Journal of Contemporary Brachytherapy
- Vol. 10 (3) , 218-224
Open AccessInitial experience using superflab as intravaginal packing during interstitial brachytherapy for advanced gynecologic cancer
Purpose: Interstitial brachytherapy implemented for locally advanced gynecologic cancer can result in toxicity due to the proximity of organs at risk (OAR). We report our experience using superflab bolus as vaginal packing to displace OAR during interstitial brachytherapy. Material and methods: Twelve patients with stage IB-IVA gynecologic cancer were treated with definitive chemoradiation including interstitial brachytherapy. A Syed template was used for a computed tomography (CT)-based preplan with magnetic resonance imaging (MRI) fusion. A 1-2 cm superflab bolus was cut and sterilized. The tandem and obturator were placed, and superflab was then inserted into the vagina. Interstitial needles were then placed through the template and superflab as per the pre-plan under transabdominal ultrasound guidance. Prescription doses ranged from 85-90 Gy EQD(2) including external beam radiation therapy (EBRT). 5-6 Gy per fraction was delivered biologically effective dose (BID) over 2-3 days in 1-2 implants. Toxicities were evaluated post-treatment, 1 month, and 3 months. Results: The rectum, bladder, and sigmoid had significant average displacement from the prescription isodose line. The average reduction in D-2cc between pre- and post-implant was 5.19 Gy per fraction (p < 0.0001), 7.19 Gy (p < 0.0004), and 1.78 Gy (p < 0.003) for the rectum, bladder, and sigmoid, respectively. The high-risk target volume (HR-TV) received a median D-90 of 104% (range, 58-122%) of the prescription dose, and 92% (range, 71-131%) in the pre-/post-implant plans, respectively (p = 0.4). Conclusions: Our initial experience with superflab as vaginal packing demonstrates technical feasibility and dosimetric improvement for OAR.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 114301
Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator
The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm3 water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm2 and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 114301
Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator
The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm3 water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm2 and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S113
Initial Experience Using Intravaginal Superflab as Packing During Interstitial Implants for Cervical Cancer
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S113
Initial Experience Using Intravaginal Superflab as Packing During Interstitial Implants for Cervical Cancer
- Open Access
- 14 January 2016
- Published by Wiley in Medical Physics
- Vol. 43 (2) , 796-806
Absolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements
Purpose: Energy‐based source strength metrics may find use with model‐based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low‐dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low‐dose rate, photon‐emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work.Methods: A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four 125I sources with air‐kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39–0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air‐kerma strengths to EPs through Monte Carlo‐derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique.Results: The calorimeter had a noise floor of 1–3 nW and a repeatability of 30–60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level.Conclusions: A calorimeter capable of measuring the EP from LDR sources has been developed and validated for 125I sources with EPs between 0.43 and 0.79 μW.
- 14 January 2016
- Published by Wiley in Medical Physics
- Vol. 43 (2) , 796-806
Open AccessAbsolute measurement of LDR brachytherapy source emitted power: Instrument design and initial measurements
Purpose: Energy‐based source strength metrics may find use with model‐based dose calculation algorithms, but no instruments exist that can measure the energy emitted from low‐dose rate (LDR) sources. This work developed a calorimetric technique for measuring the power emitted from encapsulated low‐dose rate, photon‐emitting brachytherapy sources. This quantity is called emitted power (EP). The measurement methodology, instrument design and performance, and EP measurements made with the calorimeter are presented in this work.Methods: A calorimeter operating with a liquid helium thermal sink was developed to measure EP from LDR brachytherapy sources. The calorimeter employed an electrical substitution technique to determine the power emitted from the source. The calorimeter's performance and thermal system were characterized. EP measurements were made using four 125I sources with air‐kerma strengths ranging from 2.3 to 5.6 U and corresponding EPs of 0.39–0.79 μW, respectively. Three Best Medical 2301 sources and one Oncura 6711 source were measured. EP was also computed by converting measured air‐kerma strengths to EPs through Monte Carlo‐derived conversion factors. The measured EP and derived EPs were compared to determine the accuracy of the calorimeter measurement technique.Results: The calorimeter had a noise floor of 1–3 nW and a repeatability of 30–60 nW. The calorimeter was stable to within 5 nW over a 12 h measurement window. All measured values agreed with derived EPs to within 10%, with three of the four sources agreeing to within 4%. Calorimeter measurements had uncertainties ranging from 2.6% to 4.5% at the k = 1 level. The values of the derived EPs had uncertainties ranging from 2.9% to 3.6% at the k = 1 level.Conclusions: A calorimeter capable of measuring the EP from LDR sources has been developed and validated for 125I sources with EPs between 0.43 and 0.79 μW.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1747 (1) , 110001
Challenges and opportunities in calorimetry for clinical radiation dosimetry
Primary Standard Dosimetry Laboratories establish the standards of absorbed dose to water (ADW) using calorimetry. This is because calorimetry is the most direct method to account for the energy imparted to matter by radiation. The traditional calorimetry framework is based on the use of thermistors to measure temperature changes. There are some drawbacks for the use of thermistors in radiation calorimetry and different approaches for temperature measurement are under investigation. One of these techniques uses the temperature dependence of the refractive index of water to measure with an interferometer the radiation-induced temperature changes. This work presents a comparison in calorimetric dose measurements using thermistors and interferometry. A circuit for thermistor-based measurements was designed and characterized. For interferometer-based measurements, a Michelson interferometer was built. Phase shifts in one of the interferometer arms were calculated from the intensity changes measured with an unbiased photodiode placed at the center of the interference fringe. Radiation-induced temperature rises were measured simultaneously with the interferometer and thermistor in a glass phantom filled with water. The water phantom was irradiated with 200, 300, 400 and 500 monitor units from a 6 MV photon beam using a linear accelerator Varian 21 EX. Results. The thermistor circuit built was able to achieve micro-kelvin resolution. Absorbed dose to water measurements performed with the interferometer agreed within the uncertainty with thermistor-based measurements. Time dependent temperature curves showed that heat transfer after irradiations was higher for thermistor than for the interformetric technique due to the thermistor overheating. The equivalent type-A uncertainty was 0.32 Gy for the interferometric measurements and 0.05 Gy for thermistor-based measurements. Thermal fluctuations in the water phantom have a higher contribution to measurement uncertainty for interferometer-based measurements. Improved precision in interferometer-based measurements will require increasing the thermal insulation or the water phantom and using a stabilized laser. Up to date, interferometer-based measurements are feasible in the dose range of interest for external beam therapy, but further investigation is necessary to achieve a precision comparable with the thermistor framework.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1747 (1) , 110001
Challenges and opportunities in calorimetry for clinical radiation dosimetry
Primary Standard Dosimetry Laboratories establish the standards of absorbed dose to water (ADW) using calorimetry. This is because calorimetry is the most direct method to account for the energy imparted to matter by radiation. The traditional calorimetry framework is based on the use of thermistors to measure temperature changes. There are some drawbacks for the use of thermistors in radiation calorimetry and different approaches for temperature measurement are under investigation. One of these techniques uses the temperature dependence of the refractive index of water to measure with an interferometer the radiation-induced temperature changes. This work presents a comparison in calorimetric dose measurements using thermistors and interferometry. A circuit for thermistor-based measurements was designed and characterized. For interferometer-based measurements, a Michelson interferometer was built. Phase shifts in one of the interferometer arms were calculated from the intensity changes measured with an unbiased photodiode placed at the center of the interference fringe. Radiation-induced temperature rises were measured simultaneously with the interferometer and thermistor in a glass phantom filled with water. The water phantom was irradiated with 200, 300, 400 and 500 monitor units from a 6 MV photon beam using a linear accelerator Varian 21 EX. Results. The thermistor circuit built was able to achieve micro-kelvin resolution. Absorbed dose to water measurements performed with the interferometer agreed within the uncertainty with thermistor-based measurements. Time dependent temperature curves showed that heat transfer after irradiations was higher for thermistor than for the interformetric technique due to the thermistor overheating. The equivalent type-A uncertainty was 0.32 Gy for the interferometric measurements and 0.05 Gy for thermistor-based measurements. Thermal fluctuations in the water phantom have a higher contribution to measurement uncertainty for interferometer-based measurements. Improved precision in interferometer-based measurements will require increasing the thermal insulation or the water phantom and using a stabilized laser. Up to date, interferometer-based measurements are feasible in the dose range of interest for external beam therapy, but further investigation is necessary to achieve a precision comparable with the thermistor framework.