Olga Green
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olga Green has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Austen Curcuru
Washington University School of Medicine, St. Louis, MO, 63130, USA
3 shared publications- Jeff M. Michalski
Washington University School of Medicine, Saint Louis, MO
3 shared publications - Lauren E. Henke
Department of Radiation Oncology, Washington University School of Medicine, St Louis, MO, USA
3 shared publications Brian W. Pogue
Thayer School of Engineering and Department of Physics and Astronomy Dartmouth College Hanover NH 03755 USA
2 shared publications- Cliff Grant Robinson
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
2 shared publications Clifford G. Robinson
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
2 shared publications
Latest Publications
- Open Access
- 24 October 2023
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 44, 100693
CT-based online adaptive radiotherapy improves target coverage and organ at risk (OAR) avoidance in stereotactic body radiation therapy (SBRT) for prostate cancer
- 24 October 2023
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 44, 100693
Open AccessCT-based online adaptive radiotherapy improves target coverage and organ at risk (OAR) avoidance in stereotactic body radiation therapy (SBRT) for prostate cancer
- 12 October 2022
- Published by Springer Nature
- p. 159-177
MR-Integrated Linear Accelerators: First Clinical Results
- 12 October 2022
- Published by Springer Nature
- p. 159-177
MR-Integrated Linear Accelerators: First Clinical Results
- Open Access
- 1 July 2021
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 6 (4) , 100662
The Role of MRI-Guided Radiation Therapy for Palliation of Mobile Abdominal Cancers: A Report of Two Cases
- 1 July 2021
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 6 (4) , 100662
Open AccessThe Role of MRI-Guided Radiation Therapy for Palliation of Mobile Abdominal Cancers: A Report of Two Cases
- Open Access
- 12 December 2019
- Published by Springer Nature in Cureus
- Vol. 11 (12) , e6364
Dosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (Dmax: 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord Dmax: 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) Dmax: 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.
- 12 December 2019
- Published by Springer Nature in Cureus
- Vol. 11 (12) , e6364
Open AccessDosimetric Feasibility of Utilizing the ViewRay Magnetic Resonance Guided Linac System for Image-guided Spine Stereotactic Body Radiation Therapy
Introduction: Spine stereotactic body radiation therapy (SBRT) achieves favorable outcomes compared to conventional radiotherapy doses/fractionation. The spinal cord is the principal dose-limiting organ-at-risk (OAR), and safe treatment requires precise immobilization/localization. Therefore, image guidance is paramount to successful spine SBRT. Conventional X-ray imaging and alignment to surrogate bony anatomy may be inadequate, whereas magnetic resonance imaging (MRI) directly visualizes the dose-limiting cord. This work assessed the dosimetric capability of the ViewRay (ViewRay Inc. Oakwood Village, OH) magnetic resonance (MR) guided linac (MR-Linac) for spine SBRT. Methods: Eight spine SBRT patients without orthopedic hardware who were previously treated on a TrueBeam using volumetric modulated arc therapy (VMAT) were re-planned using MR-Linac fixed-field intensity-modulated radiation therapy (IMRT). Phantom measurements using film, ionization chamber, and a commercial diode-array assessed feasibility. Plans included a variety of prescriptions (30-50 Gy in 3-10 fractions). Results: MR-Linac plans satisfied all clinical goals. Compared to VMAT plans, both entrance dose and heterogeneity increased (Dmax: 134±3% vs. 120±2%, p=0.0270), while conformality decreased (conformity index: 1.28±0.06 vs. 1.06±0.06, p=0.0005), and heterogeneity increased. However, while not statistically significant, MR-linac cord sparing improved (cord Dmax: 16.1±2.7Gy vs. 19.5±1.6Gy, p=0.2066; cord planning organ at risk volume (cord PRV) Dmax: 20.0±2.6Gy vs. 24.5±2.0Gy, p=0.0996). Delivery time increased but was acceptable (14.39±1.26min vs. 9.57±1.19min). Ionization chamber measurements agreed with planned dose to within 2.5%. Film and diode measurements demonstrated accurate/precise delivery of dose gradients between the target and the cord. Conclusion: Spine SBRT with the MR-Linac is feasible as verified via re-planning eight clinical cases followed by delivery verification in phantoms using film, diodes, and an ionization chamber. Real-time visualization of the dose-limiting cord during spine SBRT may enable cord-based gating, reduced margins, alternate dose schemas, and/or adaptive therapy.
- 10 December 2019
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 1258-1267
Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR‐linac
Purpose: Treatment planning systems (TPSs) for MR‐linacs must employ Monte Carlo‐based simulations of dose deposition to model the effects of the primary magnetic field on dose. However, the accuracy of these simulations, especially for areas of tissue‐air interfaces where the electron return effect (ERE) is expected, is difficult to validate due to physical constraints and magnetic field compatibility of available detectors. This study employs a novel dosimetric method based on remotely captured, real‐time optical Cherenkov and scintillation imaging to visualize and quantify the ERE.Methods: An intensified CMOS camera was used to image two phantoms with designed ERE cavities. Phantom A was a 40 cm × 10 cm × 10 cm clear acrylic block drilled with five holes of increasing diameters (0.5, 1, 2, 3, 4 cm). Phantom B was a clear acrylic block (25 cm × 20 cm × 5 cm) with three cavities of increasing diameter (3, 2, 1 cm) split into two halves in the transverse plane to accommodate radiochromic film. Both phantoms were imaged while being irradiated by 6 MV flattening filter free (FFF) beams within a MRIdian Viewray (Viewray, Cleveland, OH) MR‐linac (0.34 T primary field). Phantom A was imaged while being irradiated by 6 MV FFF beams on a conventional linac (TrueBeam, Varian Medical Systems, San Jose, CA) to serve as a control. Images were post processed in Matlab (Mathworks Inc., Natick, MA) and compared to TPS dose volumes.Results: Control imaging of Phantom A without the presence of a magnetic field supports the validity of the optical image data to a depth of 6 cm. In the presence of the magnetic field, the optical data shows deviations from the commissioned TPS dose in both intensity and localization. The largest air cavity examined (3 cm) indicated the largest dose differences, which were above 20% at some locations. Experiments with Phantom B illustrated similar agreement between optical and film dosimetry comparisons with TPS data in areas not affected by ERE.Conclusion: There are some appreciable differences in dose intensity and spatial dose distribution observed between the novel experimental data set and the dose models produced by the current clinically implemented MR‐IGRT TPS.
- 10 December 2019
- Published by Wiley in Medical Physics
- Vol. 47 (3) , 1258-1267
Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR‐linac
Purpose: Treatment planning systems (TPSs) for MR‐linacs must employ Monte Carlo‐based simulations of dose deposition to model the effects of the primary magnetic field on dose. However, the accuracy of these simulations, especially for areas of tissue‐air interfaces where the electron return effect (ERE) is expected, is difficult to validate due to physical constraints and magnetic field compatibility of available detectors. This study employs a novel dosimetric method based on remotely captured, real‐time optical Cherenkov and scintillation imaging to visualize and quantify the ERE.Methods: An intensified CMOS camera was used to image two phantoms with designed ERE cavities. Phantom A was a 40 cm × 10 cm × 10 cm clear acrylic block drilled with five holes of increasing diameters (0.5, 1, 2, 3, 4 cm). Phantom B was a clear acrylic block (25 cm × 20 cm × 5 cm) with three cavities of increasing diameter (3, 2, 1 cm) split into two halves in the transverse plane to accommodate radiochromic film. Both phantoms were imaged while being irradiated by 6 MV flattening filter free (FFF) beams within a MRIdian Viewray (Viewray, Cleveland, OH) MR‐linac (0.34 T primary field). Phantom A was imaged while being irradiated by 6 MV FFF beams on a conventional linac (TrueBeam, Varian Medical Systems, San Jose, CA) to serve as a control. Images were post processed in Matlab (Mathworks Inc., Natick, MA) and compared to TPS dose volumes.Results: Control imaging of Phantom A without the presence of a magnetic field supports the validity of the optical image data to a depth of 6 cm. In the presence of the magnetic field, the optical data shows deviations from the commissioned TPS dose in both intensity and localization. The largest air cavity examined (3 cm) indicated the largest dose differences, which were above 20% at some locations. Experiments with Phantom B illustrated similar agreement between optical and film dosimetry comparisons with TPS data in areas not affected by ERE.Conclusion: There are some appreciable differences in dose intensity and spatial dose distribution observed between the novel experimental data set and the dose models produced by the current clinically implemented MR‐IGRT TPS.
- 29 June 2018
- Published by Wiley in Medical Physics
- Vol. 45 (8) , 3728-3740
First clinical implementation of real‐time, real anatomy tracking and radiation beam control
Purpose: We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging‐guided radiation therapy (MR‐IGRT) system for real‐time tracking and beam control.Methods: The system utilizes real‐time cine imaging capabilities at 4 frames per second for real‐time tracking and beam control. Testing of the system was performed using an in‐house developed motion platform and a commercially available motion phantom. Anatomical tracking is performed by first identifying a target (a region of interest that is either tissue to be treated or a critical structure) and generating a contour around it. A boundary contour is also created to identify tracking margins. The tracking algorithm deforms the anatomical contour (target or a normal organ) on every subsequent cine frame and compares it to the static boundary contour. If the anatomy of interest moves outside the boundary, the radiation delivery is halted until the tracked anatomy returns to treatment portal. The following were performed to validate and clinically implement the system: (a) spatial integrity evaluation; (b) tracking accuracy; (c) latency; (d) relative point dose and spatial dosimetry; (e) development of clinical workflow for gating; and (f) independent verification by an outside credentialing service.Results: The spatial integrity of the MR system was found to be within 2 mm over a 45‐cm diameter field‐of‐view. The tracking accuracy for geometric targets was within 1.2 mm. The average system latency was measured to be within 394 ms. The dosimetric accuracy using ionization chambers was within 1.3% ± 1.7%, and the dosimetric spatial accuracy was within 2 mm. The phantom irradiation for the outside credentialing service had satisfactory results, as well.Conclusions: The first clinical MR‐IGRT system was validated for real‐time tracking and gating capabilities and shown to be reliable and accurate. Patient workflow methods were developed for efficient treatment. Periodic quality assurance tests can be efficiently performed with commercially available equipment to ensure accurate system performance.
- 29 June 2018
- Published by Wiley in Medical Physics
- Vol. 45 (8) , 3728-3740
First clinical implementation of real‐time, real anatomy tracking and radiation beam control
Purpose: We describe the acceptance testing, commissioning, periodic quality assurance, and workflow procedures developed for the first clinically implemented magnetic resonance imaging‐guided radiation therapy (MR‐IGRT) system for real‐time tracking and beam control.Methods: The system utilizes real‐time cine imaging capabilities at 4 frames per second for real‐time tracking and beam control. Testing of the system was performed using an in‐house developed motion platform and a commercially available motion phantom. Anatomical tracking is performed by first identifying a target (a region of interest that is either tissue to be treated or a critical structure) and generating a contour around it. A boundary contour is also created to identify tracking margins. The tracking algorithm deforms the anatomical contour (target or a normal organ) on every subsequent cine frame and compares it to the static boundary contour. If the anatomy of interest moves outside the boundary, the radiation delivery is halted until the tracked anatomy returns to treatment portal. The following were performed to validate and clinically implement the system: (a) spatial integrity evaluation; (b) tracking accuracy; (c) latency; (d) relative point dose and spatial dosimetry; (e) development of clinical workflow for gating; and (f) independent verification by an outside credentialing service.Results: The spatial integrity of the MR system was found to be within 2 mm over a 45‐cm diameter field‐of‐view. The tracking accuracy for geometric targets was within 1.2 mm. The average system latency was measured to be within 394 ms. The dosimetric accuracy using ionization chambers was within 1.3% ± 1.7%, and the dosimetric spatial accuracy was within 2 mm. The phantom irradiation for the outside credentialing service had satisfactory results, as well.Conclusions: The first clinical MR‐IGRT system was validated for real‐time tracking and gating capabilities and shown to be reliable and accurate. Patient workflow methods were developed for efficient treatment. Periodic quality assurance tests can be efficiently performed with commercially available equipment to ensure accurate system performance.
- 3 May 2018
- Published by Wiley in Medical Physics
- Vol. 45 (6) , 2647-2659
Remote Cherenkov imaging‐based quality assurance of a magnetic resonance image‐guided radiotherapy system
Purpose: Tools to perform regular quality assurance of magnetic resonance image‐guided radiotherapy (MRIgRT) systems should ideally be independent of interference from the magnetic fields. Remotely acquired optical Cherenkov imaging‐based dosimetry measurements in water were investigated for this purpose, comparing measures of dose accuracy, temporal dynamics, and overall integrated IMRT delivery.Methods: A 40 × 30.5 × 37.5 cm3 water tank doped with 1 g/L of quinine sulfate was imaged using an intensified charge‐coupled device (ICCD) to capture the Cherenkov emission while being irradiated by a commercial MRIgRT system (ViewRay™). The ICCD was placed down‐bore at the end of the couch, 4 m from treatment isocenter and behind the 5‐Gauss line of the 0.35‐T MRI. After establishing optimal camera acquisition settings, square beams of increasing size (4.2 × 4.2 cm2, 10.5 × 10.5 cm2, and 14.7 × 14.7 cm2) were imaged at 0.93 frames per second, from an individual cobalt‐60 treatment head, to develop projection measures related to percent depth dose (PDD) curves and cross beam profiles (CPB). These Cherenkov‐derived measurements were compared to ionization chamber (IC) and radiographic film dosimetry data, as well as simulation data from the treatment planning system (TPS). An intensity‐modulated radiotherapy (IMRT) commissioning plan from AAPM TG‐119 (C4:C‐Shape) was also imaged at 2.1 frames per second, and the single linear sum image from 509 s of plan delivery was compared to the dose volume prediction generated by the TPS using gamma index analysis.Results: Analysis of standardized test target images (1024 × 1024 pixels) yielded a pixel resolution of 0.37 mm/pixel. The beam width measured from the Cherenkov image‐generated projection CBPs was within 1 mm accuracy when compared to film measurements for all beams. The 502 point measurements (i.e., pixels) of the Cherenkov image‐based projection percent depth dose curves (pPDDs) were compared to pPDDs simulated by the treatment planning system (TPS), with an overall average error of 0.60%, 0.56%, and 0.65% for the 4.2, 10.5, and 14.7 cm square beams, respectively. The relationships between pPDDs and central axis PDDs derived from the TPS were used to apply a weighting factor to the Cherenkov pPDD, so that the Cherenkov data could be directly compared to IC PDDs (average error of −0.07%, 0.10%, and −0.01% for the same sized beams, respectively). Finally, the composite image of the TG‐119 C4 treatment plan achieved a 95.1% passing rate using 4%/4 mm gamma index agreement criteria between Cherenkov intensity and TPS dose volume data.Conclusions: This is the first examination of Cherenkov‐generated pPDDs and pCBPs in an MR‐IGRT system. Cherenkov imaging measurements were fast to acquire, and minimal error was observed overall. Cherenkov imaging also provided novel real‐time data for IMRT QA. The strengths of this imaging are the rapid data capture ability providing real‐time, high spatial resolution data, combined with the remote, noncontact nature of imaging. The biggest limitation of this method is the two‐dimensional (2D) projection‐based imaging of three‐dimensional (3D) dose distributions through the transparent water tank.
- 3 May 2018
- Published by Wiley in Medical Physics
- Vol. 45 (6) , 2647-2659
Remote Cherenkov imaging‐based quality assurance of a magnetic resonance image‐guided radiotherapy system
Purpose: Tools to perform regular quality assurance of magnetic resonance image‐guided radiotherapy (MRIgRT) systems should ideally be independent of interference from the magnetic fields. Remotely acquired optical Cherenkov imaging‐based dosimetry measurements in water were investigated for this purpose, comparing measures of dose accuracy, temporal dynamics, and overall integrated IMRT delivery.Methods: A 40 × 30.5 × 37.5 cm3 water tank doped with 1 g/L of quinine sulfate was imaged using an intensified charge‐coupled device (ICCD) to capture the Cherenkov emission while being irradiated by a commercial MRIgRT system (ViewRay™). The ICCD was placed down‐bore at the end of the couch, 4 m from treatment isocenter and behind the 5‐Gauss line of the 0.35‐T MRI. After establishing optimal camera acquisition settings, square beams of increasing size (4.2 × 4.2 cm2, 10.5 × 10.5 cm2, and 14.7 × 14.7 cm2) were imaged at 0.93 frames per second, from an individual cobalt‐60 treatment head, to develop projection measures related to percent depth dose (PDD) curves and cross beam profiles (CPB). These Cherenkov‐derived measurements were compared to ionization chamber (IC) and radiographic film dosimetry data, as well as simulation data from the treatment planning system (TPS). An intensity‐modulated radiotherapy (IMRT) commissioning plan from AAPM TG‐119 (C4:C‐Shape) was also imaged at 2.1 frames per second, and the single linear sum image from 509 s of plan delivery was compared to the dose volume prediction generated by the TPS using gamma index analysis.Results: Analysis of standardized test target images (1024 × 1024 pixels) yielded a pixel resolution of 0.37 mm/pixel. The beam width measured from the Cherenkov image‐generated projection CBPs was within 1 mm accuracy when compared to film measurements for all beams. The 502 point measurements (i.e., pixels) of the Cherenkov image‐based projection percent depth dose curves (pPDDs) were compared to pPDDs simulated by the treatment planning system (TPS), with an overall average error of 0.60%, 0.56%, and 0.65% for the 4.2, 10.5, and 14.7 cm square beams, respectively. The relationships between pPDDs and central axis PDDs derived from the TPS were used to apply a weighting factor to the Cherenkov pPDD, so that the Cherenkov data could be directly compared to IC PDDs (average error of −0.07%, 0.10%, and −0.01% for the same sized beams, respectively). Finally, the composite image of the TG‐119 C4 treatment plan achieved a 95.1% passing rate using 4%/4 mm gamma index agreement criteria between Cherenkov intensity and TPS dose volume data.Conclusions: This is the first examination of Cherenkov‐generated pPDDs and pCBPs in an MR‐IGRT system. Cherenkov imaging measurements were fast to acquire, and minimal error was observed overall. Cherenkov imaging also provided novel real‐time data for IMRT QA. The strengths of this imaging are the rapid data capture ability providing real‐time, high spatial resolution data, combined with the remote, noncontact nature of imaging. The biggest limitation of this method is the two‐dimensional (2D) projection‐based imaging of three‐dimensional (3D) dose distributions through the transparent water tank.
- Open Access
- 1 April 2018
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 3 (2) , 209-215
A rapid, computational approach for assessing interfraction esophageal motion for use in stereotactic body radiation therapy planning
- 1 April 2018
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 3 (2) , 209-215
Open AccessA rapid, computational approach for assessing interfraction esophageal motion for use in stereotactic body radiation therapy planning
- Open Access
- 22 March 2018
- Published by Springer Nature in Cureus
- Vol. 10 (3) , e2359
Practical Implications of Ferromagnetic Artifacts in Low-field MRI-guided Radiotherapy
Fractionated radiotherapy presents a new challenge in the screening of patients undergoing magnetic resonance imaging-guided radiotherapy (MR-IGRT). In our institution, patients are evaluated at the time of consult, simulation, and first fraction using a thorough MRI questionnaire identical to the one used for diagnostic radiology patients. For each subsequent fraction, the therapists are trained to inquire about any procedures the patient may have had between the last and current fractions. Patients are also advised to avoid food and fluid intake at least two but not beyond four hours prior to treatment. Despite these screening efforts, we have observed several non-permanent imaging artifacts that, while not harmful to the patient, prevent the accurate delivery of MR-IGRT when using online adaptive radiotherapy due to interference with the identification of relevant anatomy. Two such cases are presented here: (1) an imaging artifact due to iron-enriched breakfast cereal that precluded treatment for that day, and (2) an imaging artifact due to an iron-containing multivitamin that necessitated a creative solution to enable the accurate visualization of the area to be treated.
- 22 March 2018
- Published by Springer Nature in Cureus
- Vol. 10 (3) , e2359
Open AccessPractical Implications of Ferromagnetic Artifacts in Low-field MRI-guided Radiotherapy
Fractionated radiotherapy presents a new challenge in the screening of patients undergoing magnetic resonance imaging-guided radiotherapy (MR-IGRT). In our institution, patients are evaluated at the time of consult, simulation, and first fraction using a thorough MRI questionnaire identical to the one used for diagnostic radiology patients. For each subsequent fraction, the therapists are trained to inquire about any procedures the patient may have had between the last and current fractions. Patients are also advised to avoid food and fluid intake at least two but not beyond four hours prior to treatment. Despite these screening efforts, we have observed several non-permanent imaging artifacts that, while not harmful to the patient, prevent the accurate delivery of MR-IGRT when using online adaptive radiotherapy due to interference with the identification of relevant anatomy. Two such cases are presented here: (1) an imaging artifact due to iron-enriched breakfast cereal that precluded treatment for that day, and (2) an imaging artifact due to an iron-containing multivitamin that necessitated a creative solution to enable the accurate visualization of the area to be treated.